EEWORLDEEWORLDEEWORLD

Part Number

Search

2631LHC22301L380V3/3

Description
Rocker Switch, SPST, Latched, 15A, 12VDC, Screw Terminal, V-shaped Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size229KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2631LHC22301L380V3/3 Overview

Rocker Switch, SPST, Latched, 15A, 12VDC, Screw Terminal, V-shaped Rocker Actuator, Panel Mount

2631LHC22301L380V3/3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typeV-SHAPED ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)15 A
Contact (DC) maximum rated R load15A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationGREEN LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature55 °C
Minimum operating temperature-10 °C
method of packingBULK
sealDUST PROOF; WATER PROOF
surface mountNO
Switch actionLATCHED
switch functionSPST
Switch typeROCKER SWITCH
Termination typeSCREW
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
• Insulation resistance : 1.000 MΩ min. at 500VDC
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
3.000 Vrms 50 Hz min. between terminals and metal panel
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49

Recommended Resources

Ask: How to select ultrasonic boost transformer
[i=s]This post was last edited by chenzhouyu on 2016-9-30 17:25[/i] Hello everyone: I roughly drew an ultrasonic boost circuit, the input control signal is a square wave, the phase difference is 180°,...
chenzhouyu Analog electronics
Newcomer reporting, please come and watch!
:shy:I am very happy to join eeworld. I hope to learn and improve together with everyone here and jointly maintain a good atmosphere in the forum....
eric_wang Suggestions & Announcements
Modbus protocol address problem
When the PC communicates with the PLC via the MODBUS protocol, the mapping table given is as follows: H0000 P area H1000 M area H2000 L area H3000 K area Now I have trouble reading and writing an M190...
conniezhou Embedded System
The boss is angry. If there is no result, I will sacrifice myself! UDP communication problem on PDA, please help me, I will be grateful
The current module is the communication between PDA and MCU. 1. The code compiled under EVC4 has no problem in simulating communication through PC2003. The sending and receiving data are normal. But w...
tongwxy Embedded System
How can you run out of power at a critical moment! The world's first battery-free mobile phone is born!
In modern life, mobile phones have gradually become an indispensable part of people's lives. However, this thing may be out of power at any time! ! How can it be out of power at a critical moment! Now...
木犯001号 Power technology
How to choose the clamping voltage of TVS tube?
The board is powered by a button battery, which is 3V. TVS is used to prevent electrostatic breakdown. Under the condition of 1A test, the clamping voltage is 7V. Some people suggest using a TVS with ...
jiaodudu Discrete Device

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 43  2851  1909  771  1109  1  58  39  16  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号