EEWORLDEEWORLDEEWORLD

Part Number

Search

TPEMG24-S120200-7

Description
ACCOMMODATE UNIVERSAL AC INPUT
File Size237KB,2 Pages
ManufacturerTotal Power International
Websitehttp://www.total-power.com/
Download Datasheet Compare View All

TPEMG24-S120200-7 Overview

ACCOMMODATE UNIVERSAL AC INPUT

Total Power International, Inc.
UNIVERSAL INPUT AC-DC MEDICAL & ITE APPLICATION
EXTERNAL DESKTOP SWITCHING ADAPTER 20-24 WATTS
GREEN POWER SINGLE OUTPUT
TPEMG24
SERIES
FEATURES:
ACCOMMODATE UNIVERSAL AC INPUT
MEET MEDICAL STANDARDS IEC60601-1
& ITE STANDARDS IEC60950-1
EMI MEET EN 55011 & EN55022 /
FCC CLASS B
MEET ENERGY STAR LEVEL V &
CEC LEVEL IV
SPECIFICATION
INPUT SPECIFICATION
Input Voltage:
Typical 90-264Vac.
Input Connector:
3 pole AC inlet IEC320-C14(DT7) /
2 pole AC inlet IEC320-C8(DT8).
Input Frequency:
47-63Hz.
Inrush Current:
6.274Arms at 230Vac.
Input Current:
Typical 0.347A at 115Vac/
0.215A at 230Vac.
Dielectric Withstand:
Meet IEC60601-1 & IEC60950-1.
EMI:
Meet EN55011 & EN55022 / FCC Class B.
Hold-up Time:
Typical 16.8mS at 115Vac.
Typical 86.4mS at 230Vac.
Leakage Current:
Typical 0.25 mA for Class I
Typical 0.1mA for Class II.
No Load Power:
Less than 0.3W.
OUTPUT SPECIFICATION
Output Voltage:
See Ratings Chart.
Output Current:
See Ratings Chart.
Output Wattage:
Typical 20-24Watts.
Output Connector & Cord:
Optional.
Line Regulation:
Typical 0.1%.
Load Regulation:
Typical ±1.8%-±3%.
Noise & Ripple:
1.0% peak to peak.
OVP:
Built-in by Auto-recovery.
Adjustability:
Factory set.
Over Current Protection (OCP):
Installed.
Current limiting can be set precisely as per request.
GENERAL SPECIFICATION
Efficiency:
Typical 78%-88% (various with the output
voltage)
Switching Frequency:
Typical 55K Hz.
Circuit Topology:
Fixed Frequency Flyback circuit.
Transient Response:
Output voltage returns in less than
3mS following a 25% load change.
Safety Standard:
Meet Medical standards UL60601-1/
EN60601-1, and ITE UL60950-1/EN60950-1
Class I for DT7(C14) or Class II for DT8(C8)
Operating Temperature:
0°C to +40°C.
Storage Temperature:
-20 to +85°C.
Cooling:
Free air convection.
Construction:
Impact resistant thermo-plastic
enclosure case.
Power Density:
1.6-19.1Watts / Cubic inch.
Desktop Format.
NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current.
(4) Due to requests in market and advances in technology, specifications subject to change without notice.
For the details of safety approval, please consult the factory.
Total Power International, Inc. Toll Free: 877-646-0900(US) PH# 978-453-7272 www.total-power.com

TPEMG24-S120200-7 Related Products

TPEMG24-S120200-7 TPEMG24 TPEMG24-S050400-8 TPEMG24-S075300-7 TPEMG24-S075300-8 TPEMG24-S120200-8 TPEMG24-S150160-7 TPEMG24-S150160-8 TPEMG24-S240100-7 TPEMG24-S240100-8
Description ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT ACCOMMODATE UNIVERSAL AC INPUT
How to identify the quality of LED full-color display
The quality of a full-color display can be judged mainly from the following aspects:    1. Flatness    The surface flatness of the display screen should be within ±1mm to ensure that the displayed ima...
探路者 LED Zone
TLP521 optocoupler isolation resistor size selection problem
In the figure, the CON point should be pulled up to a high level, but the actual test shows only 0.8V. Why is this? How can I pull up the CON point to close the optocoupler switch? [[i] This post was ...
linjingui Test/Measurement
Ask a question about the design of Altera DE-2 (high score help)
Now I want to use an Altera de-2 chip to simulate the performance of a system design. One solution is to design a router by myself, and then a 3*3 mesh structure. In addition, each router is connected...
zfnlj Embedded System
C2000 Piccolo LaunchPad is 50% off
...
qinkaiabc Microcontroller MCU
The limits of power amplifier use
In order to achieve the reliability design of the power amplifier, the amplifier's tolerance must be considered. The power range limit is determined by the safe operating area (SOA) curve of the power...
fighting Analog electronics
Bendable PCB chain plate
Project from Geek Mom shows a bendable PCB chain boardProject website...
dcexpert DIY/Open Source Hardware

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 514  379  664  2285  2678  11  8  14  47  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号