EEWORLDEEWORLDEEWORLD

Part Number

Search

170M5138

Description
ELECTRIC FUSE, 250A, 1300VAC, 1300VDC, 100000A (IR), INLINE/HOLDER
CategoryCircuit protection   
File Size63KB,2 Pages
ManufacturerBussmann (Eaton)
Download Datasheet View All

170M5138 Online Shopping

Suppliers Part Number Price MOQ In stock  
170M5138 - - View Buy Now

170M5138 Overview

ELECTRIC FUSE, 250A, 1300VAC, 1300VDC, 100000A (IR), INLINE/HOLDER

High Speed Fuses
Square Body DIN 43 653 — 1250V/1300V (IEC/UL):
50-1400A
1250V/1300V (IEC/UL) 50-1400A
Specifications
Description:
Square body DIN
43 653 stud-mount high speed
fuses.
Dimensions:
See dimensions
illustration.
Ratings:
Volts: — 1250Vac (IEC)
— 1300Vac (UL)
Amps: — 50-1400A
IR: — 100kA RMS Sym.
Ag ency Information:
CE, Designed and tested to IEC
60269: Part 4, UL Recognized. Consult Cooper Bussmann
for UL Recognition/CSA Component Acceptance status.
Electrical Characteristics
Total Clearing I
2
t
1.5
K
1.25
1.0
Arc Voltage
This curve gives the peak
1.8
arc voltage, UL, which
1.4
may appear across the
fuse during its operation
10
3
8
as a function of the
applied working voltage,
6
Eg, (rms) at a power factor
5
4
of 15%.
3
3
2.5
UL
E
g
600
800
1000 1200 1400
Power Losses
Watts loss at rated current
is given in the electrical
characteristics. The curve
allows the calculation of
the power losses at load
currents lower than the
rated current. The
correction factor, Kp, is
given as a function of the
RMS load current, Ib, in %
of the rated current.
400
1.0
K
p
0.8
0.6
0.5
0.4
0.3
0.2
The total clearing I
2
t at
rated voltage and at
power factor of 15% are
0.5
given in the electrical
0.4
characteristics. For other
0.3
voltages, the clearing I
2
t
is found by multiplying by
0.2
E
g
correction factor, K,
400 600 800 1000 1200 1400
given as a function of
Dashed lines (- - - - - -) apply to the following
applied working voltage,
amperages:.
Eg, (rms).
Size
Amps.
1*
1
2
3
400A
500-630A
630-1000A
800-1400A
0.1
30 40 50
60
70
I
b
80 90 100%
Features and Benefits
• Excellent DC performance
• Low arc voltage and low energy let-through (I
2
t)
• Low watts loss
• Superior cycling capability
Typical Applications
• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters
For Other Voltage Ratings in This Body Style
• See pages 122 (690V/700V) and 146 (1000V)
Dimensions (mm)
Type -KN/110
H
20
25
25
30
108
A
Dimensions (mm)
Type -/110, -TN/110
Siz e
1*
1
2
3
A
80
80
80
81
B
138
138
138
139
D**
58
66
75
90
E
45
53
61
76
Siz e
1*
1
2
3
A
80
80
80
81
B
138
138
138
139
D
58
66
75
90
E
45
53
61
76
C
H
20
25
25
30
1mm = 0.0394” / 1” = 25.4mm
**Microswitch.
1mm = 0.0394” / 1” = 25.4mm
H
11
D
E
B
D
11
A
H
6
E
E
B
6
E
160
For product data sheets, visit www.cooperbussmann.com/datasheets/ulcsa

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1375  2621  2052  1244  1825  28  53  42  26  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号