CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 200 V, 1000 uF, THROUGH HOLE MOUNT
CategoryPassive components   
File Size653KB,11 Pages
ManufacturerETC2
Download Datasheet Parametric View All

381LX822M035J022 Online Shopping

Suppliers Part Number Price MOQ In stock  
381LX822M035J022 - - View Buy Now

381LX822M035J022 Overview

CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 200 V, 1000 uF, THROUGH HOLE MOUNT

381LX822M035J022 Parametric

Parameter NameAttribute value
negative deviation20 %
Minimum operating temperature-40 Cel
Maximum operating temperature105 Cel
positive deviation20 %
Rated DC voltage urdc200 V
Processing package descriptionROHS COMPLIANT
each_compliYes
EU RoHS regulationsYes
stateActive
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
capacitance1000 µF
dielectric materialsALUMINUM
esr__mohm_216
jesd_609_codee3
leakage_current__ma_1.34164
Manufacturer Series381LX
Installation featuresTHROUGH HOLE MOUNT
packaging shapeCYLINDRICAL PACKAGE
Package SizeSnap-in
polarityPOLARIZED
ipple_current__ma_2200
series381LX
terminal coatingTIN OVER COPPER
Terminal spacing10 mm
Terminal shapeSNAP-IN
diameter35 mm
length30 mm
Type 381LX / 383LX 105 °C High Ripple, Snap-In Aluminum
High Ripple, Long Life, 2, 4 and 5 pin styles available
Adding longer-life and more ripple capability to the excellent
value of Type 380L/LX capacitors, the 381L/LX readily handles
tough switching power supply input and output circuits and
motor-drive bus capacitor applications where the high surface
area of multiple units in parallel equals the ripple capability of our
Type 520C inverter-grade capacitor. Type 381LX delivers more
capacitance per can size while Type 381L gives lower ESR for the
same capacitance rating. Type 383L/LX has 4 or 5 leads for stable,
reverse-proof mounting.
Highlights
- Top performance in power supplies and motor drives
- 4 times the life of Type 380L/LX
- 2, 4 and 5 leads available
- Big selection of 42 case sizes
–40 °C to + 105 °C ≤ 315 Vdc
–25 °C to + 105 °C ≥ 350 Vdc
10 Vdc to 450 Vdc
33 µF to 150,000 µF
± 20%
≤3 √CV µA, 4 mA max, 5 minutes
Ambient Temperature
45 °C
381L
383L
381LX,
383 LX
Frequency
50 Hz
10-100 Vdc
160-450 Vdc
Low Temperature Characteristics
0.93
0.75
60 Hz
0.95
0.80
120 Hz
1.00
1.00
500 Hz
1.05
1.20
1 kHz
1.08
1.25
5 kHz
& up
1.15
1.40
2.70
2.35
60 °C
2.60
2.20
70 °C
2.50
2.00
85 °C 105°C
2.10
1.70
1.00
1.00
Specifications
Temperature Range
Rated Voltage Range
Capacitance Range
Capacitance Tolerance
Leakage Current
Ripple Current Multipliers
Impedance ratio: Z
–20⁰C
∕ Z
+25⁰C
≤ 10 (10 Vdc)
≤ 8 (16–50 Vdc)
≤ 4 (63–100 Vdc)
≤ 3 (150–450 Vdc)
3000 h at full load at 105 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
1000 h at 105 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
10 to 55 Hz, 0.06” and 10 g max, 2 h each plane
RoHS Compliant
Endurance Life Test
Shelf Life Test
Vibration
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800
30 EMC standard circuits shared, it will be too late if you don’t save them now!
01AC24V interface EMC design standard circuit02AC110V-220VEMC design standard circuit03AC380V interface EMC design standard circuit04AV interface EMC design standard circuit05CAN interface EMC design ...
btty038 RF/Wirelessly
A relatively easy-to-use "image to array" software
A relatively easy-to-use "image to array" software...
一江流苏 Microcontroller MCU
The gap between you and an outstanding electronic engineer (reprinted)
What is the gap between you and an outstanding electronic engineer? (Reprinted) Time: 2011-03-16 12:26:19 Source: Internet Author:  Nowadays, electronic engineers are equal to barcode technical talent...
子诺如歌 Talking about work
What are the benefits of connecting 2 NOT gates in series?
What are the benefits of connecting two NOT gates in series? In what situations are they generally used? Please tell me, thank you....
ttaid Analog electronics
Application principle of thermocouple
Thermocouple is one of the most commonly used temperature detection elements in industry. Its advantages are: ① High measurement accuracy. Because the thermocouple is in direct contact with the object...
totopper Industrial Control Electronics
Multiple peripherals on the STM32 FSMC bus cannot be accessed simultaneously in a multitasking environment
An MD9000A + an SRAM is attached to the external bus of STM32. Run ucos + lwip.Do not use external SRAM. Everything is OK, the program is very stable.But as long as the system heap space is placed in ...
luliku stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1601  2344  1274  2905  2482  33  48  26  59  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号