EEWORLDEEWORLDEEWORLD

Part Number

Search

MR50-110S24RW

Description
Compact, 50W Wide Input Railway DC/DC Converter
File Size770KB,4 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet Compare View All

MR50-110S24RW Overview

Compact, 50W Wide Input Railway DC/DC Converter

MR50-xxSRW
Series
Compact, 50W
Wide Input Railway
DC/DC Converter
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Key Features:
50W Output Power
Meets EN 50155
EN 60950 Approved
EN 50121-3-2 Compliant
Wide Input Range
3,000 VAC rms Isolation
Reinforced Insulation
92% Efficiency
Meets EN 61373
Remote On/Off
Parameter
Input Voltage Range
Input Start Voltage
Under Voltage Shutdown
Input Filter
Conditions
Min.
72 VDC Input 43.0
110 VDC Input 66.0
72 VDC Input
110 VDC Input
72 VDC Input
110 VDC Input
PI ( ) Filter
Conditions
V
IN
= Min to Max
I
OUT
= 0% to 100%
See Note 1
25% Load Change
Min.
Typ.
72.0
110.0
Max.
101.0
160.0
43.0
66.0
Units
VDC
VDC
VDC
40.0
63.0
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Transient Response Time, See Note 2
Temperature Coefficient
Output Over Load Protection
Output Short Circuit
Typ.
Max.
±1.0
±0.2
±0.3
Units
%
%
%
mV Pk-Pk
µS
%/°C
%I
OUT
100
250
±0.02
See Note 3
150
Continuous (Hiccup Mode)
Conditions
Input/Output
Input/Output to Case
500 VDC
100 kHz/1V
Min.
3,000
1,500
1,000
Typ.
Max.
General
Parameter
Isolation Voltage, Reinforced Insulation
Isolation Resistance
Isolation Capacitance
Switching Frequency
Units
VAC rms
VDC
M
pF
kHz
Units
°C
°C/W
3,000
320
Environmental
Parameter
Operating Temperature Range
Thermal Impedance, Without Heat Sink
Conditions
Ambient, See Note 4
Natural Convection
100 LFM
200 LFM
400 LFM
Natural Convection
100 LFM
200 LFM
400 LFM
Base Plate
Base Plate
RH, Non-condensing
Min.
-40
7.5
6.1
5.3
3.9
6.8
4.1
3.3
2.2
-40
Typ.
+25
Max.
+75
Thermal Impedance, With Heat Sink
Operating Temperature Range
Thermal Shutdown
Cooling
Humidity
°C/W
+105
°C
+110
°C
See Derating Curves (Page 3)
95
%
Physical
Case Size
Case Material
Weight
2.28 x 1.45 x 0.78 Inches (57.90 x 36.8 x 20.00 mm)
Black Anodized Aluminum Case with Aluminum Plate/Heat Sink
2.6 Oz (74.0g)
Conditions
Min.
Typ.
Max.
3.5 VDC - 12.0 VDC or Open Circuit
0 VDC - 1.2 VDC or Short Circuit
V
CTRL
= 5V
0.5
V
CTRL
= 0V
-0.5
Referenced to -V
IN
(Pin 3)
2.5
Min.
314.9
Min.
-0.7
-0.7
Typ.
Max.
Units
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Remote On/Off
Parameter
Unit On
Unit Off
Control Input Current, ON
Control Input Current, OFF
Control Common
Standby Input Current
mA
mA
mA
Units
kHrs
Units
VDC
°C
Reliability Specifications
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Absolute Maximum Ratings,
See Note 5
Parameter
Conditions
77 VDC Input
Input Voltage Surge (100 mS)
110 VDC Input
Lead Temperature
1.5 mm From Case for 10 Sec
Parameter
MTBF
Typ.
Max.
165.0
250.0
260
www.micropowerdirect.com

MR50-110S24RW Related Products

MR50-110S24RW MR50-110S05RW MR50-110S12RW MR50-110S15RW MR50-72S05RW MR50-72S12RW MR50-72S15RW MR50-72S24RW
Description Compact, 50W Wide Input Railway DC/DC Converter Compact, 50W Wide Input Railway DC/DC Converter Compact, 50W Wide Input Railway DC/DC Converter Compact, 50W Wide Input Railway DC/DC Converter Compact, 50W Wide Input Railway DC/DC Converter Compact, 50W Wide Input Railway DC/DC Converter Compact, 50W Wide Input Railway DC/DC Converter Compact, 50W Wide Input Railway DC/DC Converter
Battery Self-Discharge and Battery Life
When designing a smart meter, water meter, or parking detector based on NB-IOT, one of the first issues that needs to be solved is the battery life. I hope that the battery will not need to be replace...
qwqwqw2088 Energy Infrastructure?
adc0809, A/D conversion
Teacher, this is my modification on the above program. Use dd[8][2] to store the upper and lower limits of the temperature in the array. dd[add][0] stores the upper limit, and dd[add][1] stores the lo...
15075039ZQ MCU
MCU Selection
:)...
zhjie1221 NXP MCU
Talk about my understanding of inverter from the program aspect
[table=98%] [tr][td][align=center][font=Tahoma][size=5]Talk about my understanding of inverter from the programming perspective[/size][/font][/align] [font=Tahoma][align=left] I am working on somethin...
木犯001号 Power technology
About 485 communication protocol in C language
I am learning how to program 485 communication using C language. There are two single-chip computers communicating. Each byte in assembly language has parity check. How does C language check? Some pro...
jingdongbo MCU
Errors in compiling WINCE4.2 to generate an image
I am a novice learning embedded system. When I generate an image with WINCE4.2, I make an error. I also follow the book, but when I compile, I get the error message DIRECTX_MODULES= ceplayer mp3dmod w...
65687831 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1609  486  1862  2084  1627  33  10  38  42  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号