EEWORLDEEWORLDEEWORLD

Part Number

Search

21-02.5-181CPTL

Description
Interconnection Device
CategoryThe connector    The connector   
File Size184KB,3 Pages
ManufacturerAries Electronics
Download Datasheet Parametric View All

21-02.5-181CPTL Overview

Interconnection Device

21-02.5-181CPTL Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Cable Length:
“L” in inches
(2” min. length)
Ex: -0002- = 2”
-02.5 = 2.5”
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
“HT”=High temperature cable insulation
“TL” = Tin/Lead Plating
“P”=Polarization stripe included
Bend Options:
“A” = Both ends bent 90?, same direction
“B” = One male end bent 90?
“C” = Both ends bent 90?, opposite direction
“D” = One female end bent 90?
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-186APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
http://www.arieselec.com • info@arieselec.com
NORTH AMERICA
Frenchtown, NJ USA
TEL:(908) 996-6841
FAX:(908) 996-3891
abc
EUROPE
TEL: +44 870 240 0249
FAX: +44 871 919 6033
europe@arieselec.com
11019
REV.H
Page
1 of 3
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
EE TALK——What did we electronic engineers buy on Singles’ Day?
[font=微软雅黑][size=3][color=#000000] Today, my colleagues and I in the forum Q group are talking about Singles Day and sharing the spoils we bought{:1_144:}. I wonder what equipment did you guys buy for...
eric_wang Talking
A device connected to the system is not functioning
I have compiled a NDIS filter for VISTA. Now it cannot be loaded with osrloader. The error is "the device connected to the system is not functioning". I tried compiling the filter that comes with WDK6...
ieangel Embedded System
Why is there no Application.StartupPath in smart device programming?
Tip: Application does not have this StartupPath attribute...
stone_111 Embedded System
Problems with STM32F103C8T6 standby mode
[backcolor=rgb(222, 240, 251)]I am working on a project that is battery powered, so low power consumption is required. [/backcolor] [backcolor=rgb(222, 240, 251)]The sleep mode I used originally does ...
chenbingjy stm32/stm8
Newcomer Report
I'm a new member, please give me your advice....
twkj168 Talking
The program can run on a bare metal machine, so why can't it run when added to the system?
A bare metal program, the temperature sensor bare metal can be tested and the serial port can print temperature information. Why is it transplanted to the wince operating system and made into a driver...
che3ccc Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2471  2100  1599  977  810  50  43  33  20  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号