110 VDC Input for Rail Applications
CategoryPower/power management    The power supply circuit   
File Size192KB,4 Pages
ManufacturerXP Power
Websitehttps://www.xppower.com/
Download Datasheet Parametric Compare View All

RDQ100110S24 Online Shopping

Suppliers Part Number Price MOQ In stock  
RDQ100110S24 - - View Buy Now

RDQ100110S24 Overview

110 VDC Input for Rail Applications

RDQ100110S24 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
MakerXP Power
package instruction,
Reach Compliance Codecompli
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
DC DC
100 150 Watts
RDQ Series
Up to 92% Efficiency
xppower.com
110 VDC Input for Rail Applications
Quarter and Half Brick Packages
40 °C to +100 °C Operating Temperature
Baseplate cooled
Remote On/Off & Remote Sense
3 Year Warranty
Specification
Input
Input Voltage Range
Input Current
Idle Current
Input Filter
Undervoltage Lockout
Input Surge
66-160 VDC
See table
50 mA
Pi network (see note 3)
Turn on 62.0 V, turn off 56.0 V
180 VDC for 100 ms
Environmental
Operating Base Plate
Temperature
Storage Temperature
Operating Humidity
Cooling
Cooling Test
Dry Heat
Damp Heat
Vibration
Shock
• -40 °C to +100 °C, see derating curve
-55 °C to +105 °C
Up to 95% non-condensing
Baseplate-cooled, see derating curve
EN60068-2-1, -40 °C for 2 hours
EN60068-2-2, 70 °C for 6 hours
EN60068-2-30, 25 °C to 55 °C, 90-100%
humidity, 2 cycles of 24 hours
EN61373, 2 Hz to 150 Hz, 5.72m/s
2
on X
axis, 2.55m/s
2
on Y axis, 3.96m/s
2
on Z axis
EN61373, 50m/s
2
half sine 30ms, 3
positive and 3 negative on X axis,
30m/s
2
half sine 30ms, 3 positive and 3
negative on Y and Z axes,
EN50155, 0.7 to 1.4 Vn
EN50155, 100% for 10 ms
EN50155, 0.6 Vn for 100 ms
EN50155, 500 VDC
EN50155, 2250 VDC
EN50155, 1.4 Vn for 0.1 s
Output
• ±10%, see application notes
• ±1.5% max
• ±0.2% max measured from high line
to low line
Load Regulation
• ±0.2% max measured from 0-100% load
Start Up Time
• 60 ms typical
Transient Response
• 5% max deviation, recovery to within
1% in 200 µs, 25% step load change
Ripple & Noise
• 5 V models: 100 mV pk-pk
12 V models: 150 mV max pk-pk
24 V models: 240 mV max pk-pk
20 MHz bandwidth (see note 1)
Overvoltage Protection
• 115-140%
Short Circuit Protection
• Continuous
Current Limit
• 110-180% nominal output
Thermal Shutdown
• Case temperature >105 °C typical
Temperature
• ±0.03%/°C
Coefficient
Remote On/Off
• Referenced to -Vin,
Module on = open circuit,
Module off ≤0.8 VDC
Remote Sense
• Compensates up to 10% of Vout nominal,
total of output trim and remote sense
Output Voltage Trim
Initial Set Accuracy
Line Regulation
Supply Variation
Supply Interruption
Supply Change-Over
Insulation Test
Voltage Withstand
Supply Over-Voltage
EMC & Safety
General
Emissions
• Complies with EN50121-3-2, Railway
Applications - Electromagnetic
Compatibility for Rolling Stock Apparatus
• EN55011, 99 dBµV (0.15-0.5 MHz). 93
dBµV (0.5-30 MHz) conducted,
class A radiated, EN55022 Level B
conducted with external filter, see
Application Notes.
• EN61000-4-2 Air ±8kV, contact ±6kV,
indirect ±6kV, Perf Criteria A
• EN61000-4-3 80-1000 MHz at 20 V/m,
1400-2100 MHz at 10V/m, 2100-2500
MHz at 5 V/m, Perf Criteria A
• EN61000-4-4 level 3, Perf Criteria A
• EN61000-4-5 level 2, Perf Criteria A*
• EN61000-4-6 10 Vrms, Perf Criteria A
• UL60950-1 (basic insulation)
ESD Immunity
Radiated Immunity
EFT/Burst
Surge
Conducted Immunity
Safety Approval
General
Efficiency
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Power Density
MTBF
• See tables
• 2250 VDC Input to Output
2250 VDC Input to Case
1500 VDC Output to Case
• 10
7
• 1000 pF typical
• 200 kHz typical
• RDQ100: 60 W/in
3
, RDQ150: 54 W/in
3
• 380 kHrs typical to MIL-HDBK-217F
at 25 °C, GB
Notes
* External TVS is required on the input. See Application Notes.

RDQ100110S24 Related Products

RDQ100110S24 RDQ RDQ100110S05 RDQ100110S12 RDQ150110S05 RDQ150110S12 RDQ150110S24
Description 110 VDC Input for Rail Applications 110 VDC Input for Rail Applications 110 VDC Input for Rail Applications 110 VDC Input for Rail Applications DC DC CONVERTER 5V 150W DC DC CONVERTER 12V 150W DC DC CONVERTER 24V 150W
Is it lead-free? Lead free - Lead free Lead free Lead free Lead free Lead free
Reach Compliance Code compli - compli compli compliant compliant compliant
Analog Integrated Circuits - Other Types DC-DC REGULATED POWER SUPPLY MODULE - DC-DC REGULATED POWER SUPPLY MODULE DC-DC REGULATED POWER SUPPLY MODULE DC-DC REGULATED POWER SUPPLY MODULE DC-DC REGULATED POWER SUPPLY MODULE DC-DC REGULATED POWER SUPPLY MODULE
Digitally controlled DC current
Digitally controlled DC current...
jiao430 MCU
A silly problem with LPC2132 interrupts
#include} } I used keil to debug, but I can't enter the interrupt function. I monitor T0TC and it increases from 0 to T0MR0 and then returns to 0. What's wrong? I wrote the program according to the ma...
iloveyoulix Embedded System
Summary of Zigbee Technology [Repost]
Temperatures are rising sharply in Sonoma Valley. But the wine producer at Gecko Estate is closely monitoring its fields through small wireless Zigbee sensors on each vine. These coin-sized machines c...
2345 RF/Wirelessly
I would like to ask: (stm32), how to understand the difference and application of tim_period & TIM_PrescalerConfig? ?
TIM_Period sets the value of the auto-reload register period that is loaded into the activity at the next update event. Its value must be between 0x0000 and 0xffff. TIM_Prescaler sets the prescaler va...
yanse51 stm32/stm8
EEWORLD University ---- Practical production of IoT projects: Bluetooth 4.0 BLE development - smart bulbs - universal remote control
Practical production of IoT projects: Bluetooth 4.0 BLE development - smart bulbs - universal remote control : https://training.eeworld.com.cn/course/273293...
桂花蒸 MCU
TIVA C Launchpad Week 3 Experience --- UART
Program content: Launchpad first sends the string "2JEnter text:" to the PC. After receiving the data, the PC can send any data. After receiving the data, Launchpad can return the same data to the PC....
hjf2002 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 414  2250  2344  1014  390  9  46  48  21  8 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号