ZM90B50B01

Description
SNAP ACTING/LIMIT SWITCH, SPDT, MOMENTARY, THROUGH HOLE-RIGHT ANGLE
Categoryunclassified   
File Size769KB,1 Pages
ManufacturerHoneywell
Websitehttp://www.ssec.honeywell.com/
Download Datasheet Parametric View All

ZM90B50B01 Overview

SNAP ACTING/LIMIT SWITCH, SPDT, MOMENTARY, THROUGH HOLE-RIGHT ANGLE

ZM90B50B01 Parametric

Parameter NameAttribute value
Maximum operating temperature120 Cel
Minimum operating temperature-40 Cel
Maximum AC contact current0.1000 A
Maximum AC contact voltage125 V
stateACTIVE
Electrical life1.00E6 Cycle(s)
switch functionSPDT
terminal coatingGOLD
Manufacturer SeriesZM
Control valveSIMULATED ROLLER LEVER
width10.6 mm
high6.4 mm
length or diameter19.8 mm
Installation featuresTHROUGH HOLE-RIGHT ANGLE
maximum control0.5900 N
Switch actionMOMENTARY
Switch typeSNAP ACTING/LIMIT SWITCH
Terminal typeSOLDER
MICRO SWITCH™ ZM Series Subminiature Switch
Product Nomenclature
For example, a
ZM50E10E01
part number would define a MICRO SWITCH™ ZM Series subminiature switch with a simulated roller lever,
rated at 5 A, SPDT, 146 g max. operating force, and straight solder terminals
ZM
Switch Type
50
Current
Rating
0.1 A 125 Vac
(Gold-plated
contacts)
5 A; 125 Vac/
250 Vac
10.1 A; 125 Vac/
250 Vac
1
E
Operating Force
(at pin plunger)
60 g max.
104 g max.
146 g max.
249 g max.
104 g max.
146 g max.
249 g max.
249 g max.
10
Terminal
Type
E
Actuator Type
(Integral Levers)
Pin plunger
Short straight
lever, 16,7 mm
[0.66 in] length
Standard straight
lever, 18,7 mm
[0.74 in] length
Long straight lever,
24,8 mm [0.98 in]
length
Stnd sim. roller lever,
18,0 mm [0.71 in] length
R 2,75 mm
Roller lever, 16,6 mm
[0.65 in] length
Ø4,8 mm roller
Small sim. roller lever,
17,9 mm [0.70 in] length
R 1,3 mm
Extended straight lever,
55,2 mm [2.17 in]
length
Straight lever,
35,2 mm [1.39 in]
length
L-shaped lever,
31,5 mm [1.24 in]
length
Large sim. roller lever,
21,1 mm [0.83 in] length
R 2,45 mm
SPECIAL lever
2
01
Circuitry
Special
Designator
2
A special designator
character(s) is used
when there is a special
modification to the
switch. A special
designator is required
when Terminal Type
is “99” or Actuator
Type is “S”.
ZM
Series
Subminiature
10
Basic
Switch
50
90
B
D
E
G
D
E
G
G
10
20
50
60
70
99
Solder,
straight
PCB, straight
PCB,
right angle
PCB,
left angle
Quick connect
0.110 in
SPECIAL
2
A
B
C
D
E
F
H
J
K
L
M
01
03
04
SPDT
SPNO
SPNC
Not all combinations of model code are available.
Please contact your Honeywell representative or distributor for assistance.
NOTES:
1
Switches with 10.1 A rating are only available with “G” operating force.
2
Terminal Type “99” or Actuator Type “S” designates a special and therefore requires
a special designator character(s) at the end of the listing.
004976-3-EN IL50 GLO
January 2015
Copyright © 2015 Honeywell International Inc. All Rights Reserved.
S
Application of sensors in real-time obstacle avoidance of multi-joint robot system
This paper describes the application of sensor technology in real-time obstacle avoidance of multi-joint robot systems in recent years, introduces in detail the selection of sensors and multi- sensor ...
frozenviolet Robotics Development
stm32printf help
printf("ADC sampling value is %d",ADC3ConvertedValue); printf("ADC measurement value is %f",ADC3ConvertedVoltage); The output effect is: ADC sampling value is 990 ADC measurement value is %f I don't k...
568760310 stm32/stm8
Quantifying Harmonic Distortion: THD Calculation Option
The proliferation of nonlinear electrical loads is threatening the reliability of the electrical grid in factories, commercial buildings, and residential buildings. What is a nonlinear load? It is any...
maylove Analogue and Mixed Signal
Introduction to flow principle in automatic monitoring system of oil and gas recovery in oil stations
[i=s]This post was last edited by Baboerben on 2019-10-13 21:03[/i]When talking about oil and gas recovery renovation, the first thing that comes to mind is the oil and gas recovery renovation of gas ...
灞波儿奔 Microcontroller MCU
Has anyone copied the JTAG part of the launchpad c2000 board?
The JTAG part of launchpad is very simple. Has anyone tried this board? Can you just copy the chips and use it? What driver is needed? This will be helpful to those friends who don't support CCS5 soft...
minjiang Microcontroller MCU
Op amp
[i=s] This post was last edited by aq1261101415 on 2019-5-29 21:36 [/i] Why am I always affected by capacitors when analyzing op amp circuits? I can't analyze them if there are capacitors. (1) What ar...
aq1261101415 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2098  1104  173  2807  1529  43  23  4  57  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号