EEWORLDEEWORLDEEWORLD

Part Number

Search

VI-RCW203-MXXWH1-CC

Description
DC-DC Regulated Power Supply Module, 3 Output, Hybrid, PACKAGE-20
CategoryPower/power management    The power supply circuit   
File Size147KB,4 Pages
ManufacturerVICOR
Websitehttp://www.vicorpower.com/
Download Datasheet Parametric View All

VI-RCW203-MXXWH1-CC Overview

DC-DC Regulated Power Supply Module, 3 Output, Hybrid, PACKAGE-20

VI-RCW203-MXXWH1-CC Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Objectid145005635129
package instructionPACKAGE-20
Reach Compliance Codenot_compliant
ECCN codeEAR99
Date Of Intro2017-11-21
Analog Integrated Circuits - Other TypesDC-DC REGULATED POWER SUPPLY MODULE
CertificationCE, TUV, UL, VDE, CSA, IEC
Maximum input voltage36 V
Minimum input voltage18 V
Nominal input voltage24 V
JESD-30 codeR-XXMA-X20
length219.2 mm
Maximum grid adjustment rate0.2%
Maximum load regulation0.2%
Number of functions1
Output times3
Number of terminals20
Maximum output voltage16.5 V
Minimum output voltage13.5 V
Nominal output voltage15 V
Package body materialUNSPECIFIED
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
ProtectOUTPUT OVER VOLTAGE
surface mountNO
technologyHYBRID
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum total power output250 W
Fine-tuning/adjustable outputYES
width187.45 mm
ComPAC
Product Highlights
DC-DC Switchers
50 to 600W
1-3 Outputs
ComPAC meets Bellcore, British
Telecom and IEC specifications for
transient protection; Bellcore, British
Telecom and FCC/VDE specifications
for EMI/RFI; and benefits from the
proven field performance, high
efficiency and inherent high reliability
of our VI-200 component-level power
converters. With input voltage ranges
optimized for industrial and
telecommunication applications,
ComPAC provides extended input
overvoltage capability, input reverse
polarity protection, undervoltage
lockout, and master disable. In a
package just .99" (25,2mm) in height,
ComPAC delivers up to 600W
from one, two or three outputs of
1 to 95Vdc.
Use the configuration chart at the right to define your
Vicor part number(s).
Features
Inputs 24, 48, and 300Vdc
Any Output: 1 to 95Vdc
High Surge Withstand:
Bellcore, British Telecom BTR 2511,
EN-61000-4-5
EMI/RFI Specifications:
Bellcore TR-TSY-000513,
British Telecom BTR 2511,
FCC Class A, EN55022 Class B
UL, CSA, TÜV (IEC 950)
80-90% Efficiency
Up to 10W/Cubic Inch
Reverse Polarity Protected
Master Disable
Overvoltage Shutdown
ComPAC Configuration Chart
Total Power
Single Outputs:
50-200W
100-400W
300-600W
Dual Outputs:
100-400W
150-600W
Triple Outputs:
150-600W
VI-LC
VI-MC
VI-NC
VI-PC
VI-QC
VI-RC
Part No.
Dimensions
8.6"L x 2.5"W x 0.99"H
(218,4 x 63,5 x 25,2mm)
8.6"L x 4.9"W x 0.99"H
(218,4 x 124,5 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
8.6"L x 4.9"W x 0.99"H
(218,4 x 124,5 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
8.6"L x 7.3"W x 0.99"H
(218,4 x 185,4 x 25,2mm)
Conduction Cooled Models Available
Add "-CC" to the end of the part number
Input Voltage
Nominal
Range
1 =
W=
3 =
N =
6 =
24V
24V
48V
48V
300V
21 - 32V (1)
18 - 36V (1)
42 - 60V (2)
36 - 76V (2)
200 - 400V (2)
Output Voltage
Z
Y
0
M
1
=
=
=
=
=
2V
3.3V
5V
10V
12V
2
3
L
4
=
=
=
=
15V
24V
28V
48V
E
C
I
M
=
=
=
=
Product Grade
-10°C to +85°C
-25°C to +85°C
-40°C to +85°C
-55°C to +85°C
(1 to 95V, consult factory)
Output Power/Current
V
out
5V
Y = 50W
X = 75W
W = 100W
V = 150W
U = 200W
V
out
< 5V
10A
15A
20A
30A
40A
Output Power/Current
V
out
5V
W = 100W
V = 150W
U = 200W
S = 300W
Q = 400W
V
out
< 5V
20A
30A
40A
60A
80A
Output Power/Current
V
out
5V
S = 300W
P = 450W
M = 600W
V
out
< 5V
60A
90A
120A
Max output for
(1)
(2)
5V Outputs
150W
200W
>5V Outputs <5V Outputs
150W
30A
200W
40A
For latest Vicor Product Information: www.vicr.com
Vers 1
11/99 1 of 4
Where to start embedded development?
I will graduate in one year. Please give me some advice. I want to enter the field of embedded development. I learned a lot in college, including LINUX operating system, brew, assembly, C, C++, JAVA, ...
fuan1981 Embedded System
What is the difference between 8550 and 9012?
What is the difference between 8550 and 9012?...
深圳小花 PCB Design
TLP3547 Evaluation Board Evaluation Report_wjunlin
[i=s] This post was last edited by wjunlin on 2018-10-9 10:19 [/i] Test environment Room temperature, adjustable power supply, load DC small motor 1. Control end test, connect different voltage no-loa...
wjunlin Toshiba Photorelays TLP3547 Review
Which software to use for PCB design
There are many kinds of software for PCB design. For a beginner, considering future development, which design software should I choose? It would be best if the experts could explain the differences be...
华光传感 PCB Design
Application of SCADA system based on PLC and MDS wireless data transmission radio in water plant (reposted)
Application of SCADA system of PLC and MDS wireless data transmission radio in water plant This paper introduces the composition and function of wireless water supply dispatching system with S7-200 PL...
totopper Industrial Control Electronics
Technical article sharing: Using minDSP Codec to improve the audio performance of smartphones
The ultra-low power miniDSP audio Codec launched by Texas Instruments integrates dual miniDSP cores, which can provide high-performance voice and music processing capabilities for battery-powered port...
德仪DSP新天地 DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2077  2205  1118  1871  823  42  45  23  38  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号