EEWORLDEEWORLDEEWORLD

Part Number

Search

XCCC2042340AB

Description
RES NET,THIN FILM,234 OHMS,200WV,.1% +/-TOL,-25,25PPM TC,1010 CASE
CategoryPassive components    The resistor   
File Size116KB,3 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Download Datasheet Parametric View All

XCCC2042340AB Overview

RES NET,THIN FILM,234 OHMS,200WV,.1% +/-TOL,-25,25PPM TC,1010 CASE

XCCC2042340AB Parametric

Parameter NameAttribute value
Objectid1170262558
package instructionSMT, 1010
Reach Compliance Codeunknown
ECCN codeEAR99
structureChip
Manufacturer's serial numberCCC
Network TypeCenter Tap
Number of terminals6
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package height0.25 mm
Package length2.5 mm
Package formSMT
Package width2.5 mm
method of packingTray
Rated power dissipation(P)0.4 W
GuidelineMIL-STD-883
resistance234 Ω
Resistor typeARRAY/NETWORK RESISTOR
seriesCCC
size code1010
Temperature Coefficient-25,25 ppm/°C
Tolerance0.1%
Operating Voltage200 V
CCC
Vishay Electro-Films
Thin Film, 1010 Center-Tapped Resistors on Alumina
CHIP
RESISTORS
FEATURES
Wire bondable
Product may not
be to scale
Larger single size for extended value range
Resistance range total: 100
Ω
to 1 MΩ
Custom values:
R
A
or
R
B
- 50
Ω
to 500 kΩ
Power: 400 mW
Alumina substrate
Low stray capacitance: < 0.2 pF
Resistor material: Nichrome
The CCC series resistor chips offer good 400 mW power, low
shunt capacitance and a center tap feature.
The CCCs nichrome resistor material offers excellent stability.
The CCCs are manufactured using Vishay Electro-Films
(EFI) sophisticated thin film equipment and manufacturing
technology.
The CCCs are 100 % electrically tested and visually
inspected to MIL-STD-883.
APPLICATIONS
Vishay EFI CCC chip resistors provide excellent high-frequency response and are ideally suited for prototyping.
Typical application areas are:
Amplifiers
Couplers
Oscillators
Filters
Attenuators
Recommended for hermetic environment where die is not exposed to moisture.
TEMPERATURE COEFFICIENT OF RESISTANCE, VALUES AND TOLERANCES
Tightest Standard Tolerance Available
0.1 %
± 10 ppm/°C
± 25 ppm/°C
± 50 ppm/°C
± 100 ppm/°C
PROCESS CODE
CLASS H*
203
200
201
202
*MIL-PRF-38534 inspection criteria
CLASS K*
207
204
205
206
100
Ω
200
Ω
500 kΩ
1 MΩ
STANDARD ELECTRICAL SPECIFICATIONS
PARAMETER
Noise, MIL-STD-202, Method 308
Center Tap Ratio,
R
A
/R
B
: Tolerance
Stability, 1000 h, + 125 °C, 400 mW
Operating Temperature Range
Thermal Shock, MIL-STD-202, Method 107, Test Condition F
High Temperature Exposure, + 150 °C, 100 h
Dielectric Voltage Breakdown
Insulation Resistance
Operating Voltage
DC Power Rating at + 125 °C
5 x Rated Power Short-Time Overload, + 25 °C, 5 s
- 20 dB typ.
1±1%
± 0.1 % max.
ΔR/R
- 55 °C to + 125 °C
± 0.25 % max.
ΔR/R
± 0.25 % max.
ΔR/R
400 V
10
12
min.
200 V max.
400 mW max.
± 0.25 % max.
ΔR/R
www.vishay.com
70
For technical questions, contact: efi@vishay.com
Document Number: 61010
Revision: 11-Mar-08
C language - transfer statement (continue/break/goto)
goto: The goto statement is used to jump to a statement you specify, and then execute from that statement onwards. The goto statement is very simple to use. First, add a label and a colon in front of ...
yanbodiaotu Programming Basics
Two experts online: For questions related to power supply, you can ask them here
If you have any questions about power supply, please ask them here. [b][color=blue]quanzx[/color][/b] and [color=blue][b]rockyltp[/b][/color] are looking forward to your discussion here. [color=#0000f...
EEW Power technology
About suspend wakeup
How to wake up s3c2440 after suspend? After suspend, the trace shows that CPUPowerOff() is executed. It is also used before suspend. s2440IOP->rGPFDAT = 0x1 |(0xfrGPFCON = 0x5502; s2440IOP->rGPFUP = 0...
dengjiescut2006 Embedded System
Are the hive files generated locally the same as the hive files imported into the board?
I initially thought that they should be the same, just changing the name of default.hv to system.hv. Later I found that the sizes were different. Has anyone studied similar problems?...
zldzjzldh Embedded System
How do company employees understand their superiors and get along with them?
A boss in the workplace is a boss. If an ordinary employee can understand the boss's employees and know the etiquette of getting along with the boss, this employee will not be ordinary. Soon he will b...
ESD技术咨询 Talking about work
Design of a non-contact torque test system
In the rotating power transmission system, torque is an important parameter in many mechanical measurements. Due to the high-speed rotation of the rotating parts in this type of system, the sensor pow...
一世轮回 Energy Infrastructure?

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2851  1208  2606  2440  1349  58  25  53  50  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号