Pb in high temperature solder (exempt per RoHS 2002/95/EC Annex (7))
Obsolete/End of Life Date: 12/31/2014 – Last Time Buy Date: March 31,2015
ABSM2
RoHS/RoHS II Compliant
12.5 x 4.6 x 3.7mm
| | | | | | | | | | | | |
| |
Please consider ABSM3A as an alternative
FEATURES:
• Suitable for RoHS compliant reflow
• Available tight tolerance and
temperature stability
STANDARD SPECIFICATIONS:
Parameters
Available Frequencies
Operation Mode
Operating Temperature
Storage Temperature
Frequency Tolerance @+25°C
Frequency Stability over the Operating
Temperature ( ref. to +25°C)
Equivalent series resistance (R1)
Shunt capacitance (C0)
Load capacitance (CL)
Drive Level
Aging
Insulation Resistance
Table 1. Standard ESR
Frequency (MHz)
3.50 - 3.999
4.000 - 5.999
6.000 - 11.999
12.000 - 32.000 (fund)
30.000 - 35.999 (3rd overtone)
33.000 - 70.000 (3rd overtone)
ESR (Ω)
max.
200
150
100
50
100
80
APPLICATIONS:
• Computers, Modems, Microprocessors
• Communication, Test equipment
• PCMCIA
Units
MHz
-----
-----
-----
ºC
ºC
ppm
ppm
Ω
pF
pF
µW
ppm
MΩ
Notes
3.50 MHz - 30.000 MHz
30.001 MHz - 70.000 MHz
30.001 MHz - 32.000 MHz
Minimum
Typical
Maximum
See Table 2 below
Fundamental:
Standard
3rd Overtone:
Standard
Fundamental:
Option.
See options below
-10
-----
+60
-55
-----
+125
-50
-----
+50
-50
-----
-----
-----
-5
500
Table 2
See options
See options
See options
-----
See table 1 below
-----
18.0
-----
-----
-----
+50
7.0
-----
100
+5
-----
Standard
(See options if
other than STD)
@25°C±3°C
First year
@ 100Vdc ± 15V
Available Frequency List [MHz]
3.579545
3.686400
3.932160
4.000000
4.032000
4.096000
4.194304
4.433619
4.800000
4.915200
5.000000
5.068800
5.120000
5.333333
5.529600
6.000000
6.144000
6.176000
6.400000
7.159090
7.372800
7.680000
8.000000
8.000156
8.192000
9.216000
9.600000
9.830400
10.000000
10.240000
10.240000
11.000000
11.059200
11.289600
12.000000
12.288000
12.352000
12.500000
13.000000
13.500000
14.318180
15.000000
15.360000
16.000000
16.000312
16.257000
16.384000
16.666000
16.667000
16.934400
16.934400
17.734475
18.000000
18.432000
18.869600
19.440000
19.660800
20.000000
20.480000
22.118400
24.000000
24.000140
24.576000
24.704000
25.000000
25.175000
27.000000
28.000000
28.322000
28.636360
29.491200
29.500000
30.000000
32.000000
32.768000
33.000000
33.333000
33.333300
33.868800
34.000000
35.468950
36.000000
40.000000
40.960000
44.000000
45.000000
47.940000
48.000000
48.000000
49.152000
50.000000
53.125000
55.000000
60.000000
64.000000
66.000000
66.666600
9.830000
14.745600 19.200000
(Left blank if standard)
OPTIONS & PART IDENTIFICATION:
ABSM2 -
Frequency in MHz*
Please specify the
frequency in MHz.
e.g. 16.000MHz
Load Capacitance (pF)*
Please specify CL (min
10pF) in pF or S for series
Custom ESR if other
than standard
R□
□:
Specify a value in
Ω
(e.g.: R40)
Operating Temp. *
E: 0°C to +70°C
B: -20°C to +70°C
C: -30°C to +70°C
N: -30°C to +85°C
D: -40°C to +85°C
Freq. Tolerance*
4: ± 30 ppm
MHz -
-
-
-
-
Packaging
Blank: Bulk
T: 1000pcs/reel
Oscillation Mode
F: Fundamental AT for
30MHz<F<32MHz
Freq. Stability*
Y: ± 30 ppm
H: ± 35 ppm
Z: ± 100 ppm
R: ± 150 ppm
*Frequency, Load Capacitance, Frequency
tolerance and stability is subject to availability.
Please contact Abracon for each option for
availability.
ABRACON IS
ISO9001:2008
CERTIFIED
CE RTIFIED
LLC
2 Faraday, Suite# B
|
Irvine
|
CA 92618
Revised:10.12.15
Ph. 949.546.8000
|
Fax. 949.546.8001
Visit
www.abracon.com
for Terms and Conditions of Sale
MOLDED PLASTIC SMD MICROPROCESSOR CRYSTAL
ABSM2
OUTLINE DRAWING:
Pb in high temperature solder (exempt per RoHS 2002/95/EC Annex (7))
RoHS/RoHS II Compliant
12.5 x 4.6 x 3.7mm
| | | | | | | | | | | | |
| |
Dimensions: Inches (mm)
TAPE & REEL:
T=Tape and reel (1000pcs/reel)
REFLOW PROFILE:
Dimensions: mm
ATTENTION:
Abracon Corporation’s products are COTS – Commercial-Off-The-Shelf products; suitable for Commercial, Industrial and, where designated,
Automotive Applications. Abracon’s products are not specifically designed for Military, Aviation, Aerospace, Life-dependant Medical applications or any application
requiring high reliability where component failure could result in loss of life and/or property. For applications requiring high reliability and/or presenting an extreme
operating environment, written consent and authorization from Abracon Corporation is required. Please contact Abracon Corporation for more information.
When I used the JTAG module of msp430F149 to download, I could download and run at first. After trying for two or three days, I suddenly couldn't download one day, and then I couldn't download anymore...
I couldn't stand the days without a screen, and the original plan was to make a GUI menu. The original board didn't have a screen, so I prepared a SPI-driven monochrome screen. When the board came out...
The video frame buffer with param IP provides a reference design. The default model in Gowin_VFB_PSRAM_RefDesign is GW2A. When I changed the model to GW1NR-9, the compiler prompted the error "ERROR (P...
Abstract: For the first time, a new idea of duty cycle extended high frequency pulse DC link inverter is proposed, and the working principle of the soft switching inverter and the three-state discrete...
Technology lies in accumulation! The first time I came into contact with LED drivers was from a DEMO board: DC input, the output is a low current of about 200MA; Due to customer needs, the company lat...
1 Introduction
A wide variety of communication cables and control cables are widely used in various instruments and control equipment. Whether the cable is well-conducted and
whether
th...[Details]
1. Introduction
Since the 1980s, with the continuous development of automotive electronic technology, there are more and more electronic control units in automobiles, such as electronic fuel i...[Details]
Abstract: In order to generate a stable excitation signal, the design of a digital frequency synthesizer is implemented on FPGA using Verilog hardware language. The design includes accumulator, wav...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
Aromatic gases are widely present in food, medicine, cosmetics and various daily chemical products, such as snacks, liquor, spices, Chinese herbal medicines, plasters, perfumes, soaps, shampoos, et...[Details]
A standard cell
is an electrochemical
cell
used as a voltage reference standard in many electrical standards laboratories
. If properly maintained, standard cells are very stable. The ...[Details]
MediaTek (2454) announced the acquisition of F-MStar (3697) and attracted the attention of IC design industry. This morning, Gartner Semiconductor Industry Research Director Hong Cenwei analyzed ...[Details]
This controller uses PIC16C54 single-chip microcomputer as the controller, and it is very easy to use: just connect a telephone line to the loudspeaker through the controller, and you can rem...[Details]
Abstract: Aiming at the needs of coal-rock acoustic emission signal monitoring system, a data acquisition circuit with 24-bit resolution and 16-channel synchronous data acquisition function is desi...[Details]
Introduction
Nowadays, people pay more and more attention to the security alarm system, and people have higher and higher requirements for the functions and performance of the alarm. This paper prop...[Details]
Introduction
X1226 has the functions of clock and calendar. The clock relies on hour, minute and second registers to track, and the calendar relies on date, week, month and year registers to tr...[Details]
0 Introduction
Ultrasonic waves
are mechanical waves with a frequency of more than 20KHz, and the propagation speed in the air is about 340 m/s (at 20°C). Ultrasonic waves can be gene...[Details]
Temperature compensated quartz crystal oscillator (TCXO) is widely used as a high-precision frequency source in communication systems, radar navigation systems, precision measurement and control sy...[Details]
0 Introduction
There are many types of sensors, and the working principles, measurement targets and measurement environments of different types of sensors vary greatly. The corresponding detection s...[Details]
The demand for improved healthcare environments is endless, so medical imaging equipment with higher resolution is needed to better observe the human body. High resolution brings problems with sign...[Details]