9506 Paired - Computer Cable for EIA RS-232 Applications
For more information please
call
1-800-Belden1
See Put-ups and Colors
Related Documents : No. 3 for
Paired Cables (Belden
Standard).pdf
Description:
24 AWG stranded (7x32) TC conductors, semi-rigid PVC insulation, twisted pairs, overall Beldfoil shield (100% coverage), 24 AWG
stranded TC drain wire (continued), PVC jacket.
PHYSICAL CHARACTERISTICS:
CONDUCTOR:
Number of Pairs
Total Number of Conductors
AWG
Stranding
Conductor Material
INSULATION:
Insulation Material
Pair Color Code Chart :
Number
1
2
3
OUTER SHIELD:
Outer Shield Material Trade Name
Outer Shield Type
Outer Shield Material
Outer Shield %Coverage
OUTER SHIELD DRAIN WIRE :
Outer Shield Drain Wire AWG
Outer Shield Drain Wire Stranding
Outer Shield Drain Wire Conductor Material
OUTER JACKET:
Page 1 of 3
6
12
24
7x32
TC - Tinned Copper
S-R PVC - Semi-Rigid Polyvinyl Chloride
Color
Black & Red
Black & White
Black & Green
Number
4
5
6
Color
Black & Blue
Black & Yellow
Black & Brown
Beldfoil®
Tape
Aluminum Foil-Polyester Tape w/Shorting Fold
100 %
24
7x32
TC - Tinned Copper
9506 Paired - Computer Cable for EIA RS-232 Applications
Outer Jacket Material
OVERALL NOMINAL DIAMETER:
Overall Nominal Diameter
MECHANICAL CHARACTERISTICS:
Operating Temperature Range
Non-UL Temperature Rating
Bulk Cable Weight
Max. Recommended Pulling Tension
Min. Bend Radius (Install)
PVC - Polyvinyl Chloride
.289 in.
-30°C To +80°C
80°C (UL AWM Style 2464)
44.6 lbs/1000 ft.
66 lbs.
3 in.
APPLICABLE SPECIFICATIONS AND AGENCY COMPLIANCE:
APPLICABLE STANDARDS:
NEC/(UL) Specification
CEC/C(UL) Specification
AWM Specification
CSA Specification
EU CE Mark (Y/N)
EU RoHS Compliant (Y/N)
EU RoHS Compliance Date (mm/dd/yyyy):
FLAME TEST:
UL Flame Test
C(UL) Flame Test
PLENUM/NON-PLENUM:
Plenum (Y/N)
Plenum Number
ELECTRICAL CHARACTERISTICS:
Nom. Characteristic Impedance
Nom. Capacitance Conductor to Conductor @ 1 KHz
Nom. Cap. Cond. to Other Cond. & Shield @ 1 KHz
Nominal Velocity of Propagation
Nom. Conductor DC Resistance @ 20 Deg. C
Nominal Outer Shield DC Resistance @ 20 Deg. C
Max. Operating Voltage - UL
Max. Recommended Current
75 Ohms
30 pF/ft
50 pF/ft
60 %
24 Ohms/1000 ft
16 Ohms/1000 ft
300 V RMS (UL AWM Style 2464)
1.5 Amps per conductor @ 25°C
N
82506
UL1685 FT4 Loading
FT4
CMG
CMG
UL Style 2464 (300 V 80°C)
AWM I A
Yes
Yes
04/01/2005
PUT-UPS AND COLORS:
Item
Description
Put-Up (ft.)
Ship Weight (lbs.)
Page 2 of 3
Jacket Color
Notes
9506 Paired - Computer Cable for EIA RS-232 Applications
9506 060100
9506 0601000
9506 060500
9506 060U1000
9506 060U500
6 PR #24 PVC FS
PVC
6 PR #24 PVC FS
PVC
6 PR #24 PVC FS
PVC
6 PR #24 PVC FS
PVC
6 PR #24 PVC FS
PVC
100
1000
500
U1000
U500
5
47
25
45
23
CHROME
CHROME
CHROME
CHROME
CHROME
C
C
C = CRATE REEL PUT-UP.
Revision Number: 1
Revision Date: 07-19-2005
© 2006 Belden Wire & Cable Company
All Rights Reserved.
Although Belden Electronics Division ("Belden") makes every reasonable effort to ensure their accuracy at the time of this publication,
information and specifications described herein are subject to error or omission and to change without notice, and the listing of such
information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "AS IS" basis, with no representations or warranties, whether express,
statutory or implied. In no event will Belden be liable for any damages (including consequential, indirect, incidental, special, punitive, or
exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described
herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden CDT Electronics Division believes this product to be in compliance with the following environmental regulations: California
Proposition 65 Consent Judgment For Wire & Cable Mfgs.(San Francisco Superior Court Nos. 312962 And 320342); EU RoHS
(Directive 2002/95/EC, 27-Jan-2003);Material manufactured prior to the compliance date may still be in stock at Belden facilities and in our
Distributor's inventory. EU ELV (Directive 2000/53/EC, 18-Sept-2000); EU WEEE (Directive 2002/96/EC, 27-Jan-2003); And EU BFR
(Directive 2003/11/EC, 6-Feb-2003). The information provided in this Product Disclosure, and the identification of materials listed as
reportable or restricted within the Product Disclosure, is correct to the best of Belden's knowledge, information and belief at the date of its
publication. The information provided in the Product Disclosure is designed only as a general guide for the safe handling, storage, and any
other operation of the product itself or the one that it becomes a part of. This Product Disclosure is not to be considered a warranty or quality
specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of
legislation and regulations based on their individual usage of the product.
Belden CDT Electronics Division declares this product to be in compliance with EU LVD (Low Voltage Directive 73/23/EEC), as amended
by directive 93/68/EEC.
Page 3 of 3