EEWORLDEEWORLDEEWORLD

Part Number

Search

3011A

Description
CAPACITOR, VARIABLE, CERAMIC, 250 V, 12 pF - 100 pF, VERTICAL ADJUSTER, THROUGH HOLE MOUNT
CategoryPassive components   
File Size1MB,22 Pages
ManufacturerETC2
Download Datasheet Parametric View All

3011A Overview

CAPACITOR, VARIABLE, CERAMIC, 250 V, 12 pF - 100 pF, VERTICAL ADJUSTER, THROUGH HOLE MOUNT

3011A Parametric

Parameter NameAttribute value
Rated DC voltage urdc250 V
stateCONSULT MFR
Installation featuresTHROUGH HOLE MOUNT
Manufacturer Series9300
multiple lapsYes
Capacitor typeVARIABLE
Terminal shapeFLAT
Maximum capacitance100 pF
Minimum capacitance12 pF
dielectric materialsCERAMIC
Adjustment directionVERTICAL
INDUSTRIAL AUTOMATION
&
PROCESS
CONTROL
CABLES
18.41
UL Instrumentation Cable
300V Power-Limited Tray Cables — Overview
Construction
Soft annealed bare or tinned copper with
PVC flame retardant insulation and jacket.
Other insulation and jacket options are
available (see table below). Communication
wire included on all multi-pair/multi-triad
1000 and 3000 series part numbers, 22 AWG
(7x30) bare copper, orange PVC insulation.
Nylon rip cord included in all PVC/PVC
instrumentation cables.
Other Construction Options:
UL Listed for PLTC
Insulation/Jacket
XLPE/PVC
XLPE/CPE
PVC/PVC
PVC/CPE
PE/PVC
FPE/PVC
TPE/TPE
XLPE/Haloarrest
®
Application
Cable jackets are resistant to sunlight,
moisture and vapor penetration. PVC/PVC
constructions, with 3 conductors or more
and 20 AWG or larger, are suitable for
direct burial.
Unshielded
Twisted non-shielded pairs and triads
provide a minimal OD allowing greater tray
and conduit fill. Non-shielded instrument
pairs may be utilized when recommended
by the instrument manufacturer and used
in a metallic conduit.
Overall Shield
Recommended for use in instrumentation
applications where signals are transmitted
in excess of 100 millivolts except in areas
where high voltage and current sources
create excessive noise interference.
The Beldfoil
®
shield with drain wire
provides 100% coverage for maximum
shield effectiveness.
Individually Shielded and
Overall Shielded
Specifications
UL Subject 13
UL Subject 2250
NEC Article 725 Class 2 and
Class 3 Circuits
NEC Type PLTC Listed, which is
approved for cable tray use in Class 1,
Division 2, hazardous areas and
non-hazardous areas, cable trays,
raceways, conduit and supported
by messenger wires.
Sunlight-resistant.
Oil-resistant per UL Class 43
NEC Type ITC per Article 727.
ITC cables may carry up to 5 amps
at 150V, which is significantly greater
than that allowed for PLTC only cables.
ITC cables may also be installed in
specific applications, per the NEC,
in addition to those allowed for PLTC.
UL 1685 (UL 1581) Vertical Tray Flame
Test comparable to IEEE 383-1974
(70,000 BTU/hr.) Flame Test.
PVC/PVC constructions are CMG, FT4,
IEEE 1202 and IEEE 383-2003 rated,
and meet ICEA T-29-520 Flame Test.
Design options — call 1-800-BELDEN-1
or 1-800-BELDEN-3.
Max. Temp Rating
90°C
90°C
105°C
105°C
75°C
75°C
105°C
90°C
Armoring Capabilities
Belden also has the capability to protect
electronic, instrumentation and control cables
with interlocking or continuous armor and
smooth or corrugated protective metal tapes.
To Specify Part Number
1
2
3456
Core
Trade
Number
Overall Armor
Jacket Type
Type
Individually shielded pairs or triads with
an overall shield are recommended for
use in instrumentation applications where
optimum noise rejection is required.
Individual pair/triad shields are fully isolated
from each other and contain a separate
drain wire for grounding, to provide
maximum protection from crosstalk and
common mode interference. Cables with
an overall shield provide additional
electrostatic noise protection.
PLTC-ER
As an option, Belden offers all PVC insulated,
PVC jacketed instrumentation cables, and
several other insulation and jackets, with a
PLTC-ER (Exposed Run) rating, formerly
referred to as Open Wiring.
Per NEC Article 725, a PLTC-ER rated cable
may be installed in an industrial establish-
ment between a cable tray and the utilization
equipment or device. A PLTC-ER rated cable
must meet the crush and impact require-
ments of UL Type MC cable By eliminating
the need for metal conduit and/or armor,
using a PLTC-ER rated cable results in
savings in both installation and maintenance.
Overall Jacket
Code
1
3
4
5
6
7
Armor
Code
2
3
8
Material
Aluminum Interlock
Steel Interlock
Continuously Corrugated Aluminum
Material
PVC
CPE
TPE
HDPE
Oil Res II
Haloarrest
®
I
Standard lengths may be subject to tolerance. Custom lengths may be available upon
request. Contact the Belden Electronics Division Customer Service Department for
additional information. 1-800-BELDEN-1 or 1-800-BELDEN-3.
F o r m o r e i n f o r m a t i o n , c o n t a c t
B e l d e n Te c h n i c a l S u p p o r t :
1 - 8 0 0 - B E L D E N - 1
• w w w . b e l d e n . c o m
18
Industrial Cables
The Secret of AGND and DGND - Grounding Principles for Mixed-Signal Devices
[i=s]This post was last edited by qwqwqw2088 on 2016-5-19 08:18[/i] [align=left][size=3][color=#a0522d] Grounding is an issue that cannot be ignored for all analog designs, and in PCB-based circuits, ...
qwqwqw2088 Analogue and Mixed Signal
Last day: Apply for domestic USB and Touchkey microcontroller CH554 evaluation board
[align=left][size=14px][size=2][color=#ffffff][backcolor=red][font=宋体]About the development board for evaluation application: [/font][font=宋体]CH554 evaluation board[/font][/backcolor][/color][/size][/...
nmg MCU
Looking for some C programming experts
I really hope to meet some experts who are good at C language programming for 51 MCU. My QQ is: 836587669...
bingbing123 MCU
arm9 ldr r13,=0x1000
I am using Feiling's ok2440. Alas, I am a newbie. AREA |DATA|,CODE,READONLY ENTRY ldr r13,=0x1000 IMPORT LedMain b LedMain END I have seen this assembly jump routine in bare metal programs such as led...
testttest ARM Technology
How to send messages in text mode using gsm modem
I test the AT command in my HyperTerminal as follows: at ok at+cmgf=1 //Set to Text mode, I don't want to use PDU mode ok at+cmgs="00310033003000330037003300330037003900380032" //Specify the mobile ph...
ggggihss Embedded System
Red Hurricane "Sharing 2009" - Free FPGA Technology Seminar - PPT Materials are now available
Activity content ● Do you want to know how to run ucLinux operating system on FPGA? ● Do you want to know how to use Matlab to develop FPGA system? ● Do you want to develop FPGA directly with C langua...
wanggq FPGA/CPLD

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1304  1667  1402  1216  2031  27  34  29  25  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号