INTEGRATED CIRCUITS
DATA SHEET
SAA3049A
Infrared remote control decoder
Product specification
Supersedes data of 1996 Apr 15
File under Integrated Circuits, IC02
1996 Sep 13
Philips Semiconductors
Product specification
Infrared remote control decoder
FEATURES
•
Decodes 64 remote control commands with a maximum
of 32 subaddresses
•
Accepts RECS80 codes with pulse position modulation
(SAA3004, SAA3007, SAA3008) or RC5 codes with
bi-phase transmission (SAA3006, SAA3010)
•
Suitable for low voltage and low SAA3049A supply
current applications
•
Adding circuitry for binary decoding allows a maximum
of 2048 commands to be used, for example 1-of-16
decoder (HEF4515).
ORDERING INFORMATION
TYPE
NUMBER
SAA3049AP
SAA3049AT
PACKAGE
NAME
DIP20
SO20
DESCRIPTION
plastic dual in-line package; 20 leads (300 mil)
plastic small outline package; 20 leads; body width 7.5 mm
GENERAL DESCRIPTION
SAA3049A
The main function of the SAA3049A is to check and
convert the received coded data (RECS80/RC5) into
latched binary outputs. The device address can be
hard-wired for a particular address, allowing several
devices in one location. Alternatively, received data with
any address can be accepted; the received data and
address are then outputs.
VERSION
SOT146-1
SOT163-1
1996 Sep 13
2
Philips Semiconductors
Product specification
Infrared remote control decoder
SYSTEM DIAGRAM
SAA3049A
handbook, full pagewidth
command acknowledge
+5
V
VCC
CA
bits
A
VBatt
REMOTE
CONTROL
TRANSMITTER
SAA3004
SAA3007
SAA3008
or
SAA3006
SAA3010
B
REMOTE
CONTROL
DECODER
C
D
E
F
CQW89A
CQY89A
IR
BPW50
IR
PREAMPLIFIER
IN
T0
SAA3049A
A0 (S0)
A1 (S1)
A2 (S2)
A3 (S3)
A4
address
toggle
data
4 MHz
MGE374
Remote control transmitters (see individual data sheet for full specification):
SAA3004: V
Batt
= 4 to 11 V (max.); 7
×
64 = 448 commands (RECS80 code).
SAA3007: V
Batt
= 2 to 6.5 V (max.); 20
×
64 = 1280 commands (RECS80 code).
SAA3008: V
Batt
= 2 to 6.5 V (max.); 20
×
64 = 1280 commands (RECS80 code).
SAA3006: V
Batt
= 2 to 7 V (max.); 32
×
64 = 2048 commands (RC5 code).
SAA3010: V
Batt
= 2 to 7 V (max.); 32
×
64 = 2048 commands (RC5 code).
Fig.1 System diagram.
1996 Sep 13
3
Philips Semiconductors
Product specification
Infrared remote control decoder
PINNING
SYMBOL
A
B
C
D
E
F
A0 (S0)
A1 (S1)
IN
GND
MODE
XTAL1
XTAL2
RESET
A4
A3 (S3)
A2 (S2)
T0
CRI
V
CC
PIN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
DESCRIPTION
data output
data output
data output
data output
data output
data output
data/address output/input
data/address output/input
digital input
ground
RC5/RECS80 mode selection
crystal oscillator
crystal oscillator
reset input
address output/input
address output/input
address output/input
T0 bit
command received indicator
supply voltage
A0 (S0) 7
A1 (S1) 8
IN 9
GND 10
MGD347
SAA3049A
handbook, halfpage
A 1
B 2
C 3
D 4
E 5
20 VCC
19 CRI
18 T0
17 A2 (S2)
16 A3 (S3)
SAA3049A
F 6
15 A4
14 RESET
13 XTAL2
12 XTAL1
11 MODE
Fig.2 Pin configuration.
1996 Sep 13
4
Philips Semiconductors
Product specification
Infrared remote control decoder
LIMITING VALUES
In accordance with the Absolute Maximum Rating System (IEC 134).
SYMBOL
V
CC
V
I
I
I
I
O
P
tot
P
o
I
DD
I
SS
T
amb
T
stg
HANDLING
supply voltage
input voltage
DC input current
DC output current
total power dissipation
power dissipation per output
positive supply current
negative supply current
operating ambient temperature
storage temperature
any pin
any pin
any pin
PARAMETER
CONDITIONS
MIN.
−0.5
−0.5
−
−
−
−
−50
−100
−40
−65
SAA3049A
MAX.
+7
V
CC
+ 0.5
−10
10
125
30
+50
+50
+85
+150
V
V
UNIT
mA
mA
mW
mW
mA
mA
°C
°C
Inputs and outputs are protected against electrostatic charge in normal handling. However, to be totally safe, it is
desirable to take normal precautions appropriate to handling MOS devices (see
“Handling MOS Devices”).
1996 Sep 13
5