EEWORLDEEWORLDEEWORLD

Part Number

Search

HRM-100-3S(09)

Description
RF Connector, 1 Contact(s), Female, Panel Mount, Cable Mount, Solder Terminal, Jack
CategoryThe connector    The connector   
File Size537KB,8 Pages
ManufacturerHirose
Websitehttp://www.hirose-connectors.com/
Environmental Compliance  
Download Datasheet Parametric Compare View All

HRM-100-3S(09) Overview

RF Connector, 1 Contact(s), Female, Panel Mount, Cable Mount, Solder Terminal, Jack

HRM-100-3S(09) Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid2022583870
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSTANDARD: MIL-C-39012
body width0.5 inch
subject depth0.376 inch
body length0.5 inch
Body/casing typeJACK
Cable typeSEMI-RIGID
Characteristic impedance50 Ω
Connector typeRF SMA CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedGold (Au)
Contact point genderFEMALE
Contact materialNOT SPECIFIED
Contact resistance4 mΩ
Contact styleCOAX
Coupling typeTHREADED
DIN complianceNO
Dielectric withstand voltage1414VAC V
Filter functionNO
IEC complianceNO
Insulation resistance500000000 Ω
insulator materialTETRAFLUORIDE
JESD-609 codee4
MIL complianceYES
Plug informationMULTIPLE MATING PARTS AVAILABLE
Installation methodSTRAIGHT
Installation typeCABLE AND PANEL
Number of ports1
Maximum operating frequency12.4 GHz
OptionsGENERAL PURPOSE
Panel mountingYES
GuidelineMIL
reliabilityCOMMERCIAL
Shell materialSTAINLESS STEEL
Termination typeSOLDER
Total number of contacts1
voltage standing wave ratio1.24
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.

HRM-100-3S(09) Related Products

HRM-100-3S(09) HRM-100-6S(09) HRM-111(40)
Description RF Connector, 1 Contact(s), Female, Panel Mount, Cable Mount, Solder Terminal, Jack RF Connector, 1 Contact(s), Female, Panel Mount, Cable Mount, Jack RF SMA Connector, 1 Contact(s), Female, Panel Mount, Cable Mount, Solder Terminal, Locking, Jack
Is it Rohs certified? conform to conform to conform to
Objectid 2022583870 2022583873 8156921824
Reach Compliance Code unknown unknown unknown
ECCN code EAR99 EAR99 EAR99
Other features STANDARD: MIL-C-39012 STANDARD: MIL-C-39012 STANDARD: MIL-C-39012
subject depth 0.376 inch 0.309 inch 0.327 inch
Body/casing type JACK JACK JACK
Cable type SEMI-RIGID SEMI-RIGID SEMI-RIGID
Characteristic impedance 50 Ω 50 Ω 50 Ω
Connector type RF SMA CONNECTOR RF CONNECTOR RF SMA CONNECTOR
Contact to complete cooperation NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Contact point gender FEMALE FEMALE FEMALE
Contact material NOT SPECIFIED NOT SPECIFIED NOT SPECIFIED
Contact resistance 4 mΩ 4 mΩ 4 mΩ
Contact style COAX COAX COAX
Coupling type THREADED THREADED THREADED
DIN compliance NO NO NO
Dielectric withstand voltage 1414VAC V 1400VAC V 1400VAC V
Filter function NO NO NO
IEC compliance NO NO NO
Insulation resistance 500000000 Ω 500000000 Ω 500000000 Ω
insulator material TETRAFLUORIDE TETRAFLUORIDE TETRAFLUORIDE
MIL compliance YES YES YES
Installation method STRAIGHT STRAIGHT STRAIGHT
Installation type CABLE AND PANEL CABLE AND PANEL CABLE AND PANEL
Number of ports 1 1 1
Maximum operating frequency 12.4 GHz 12.4 GHz 12.4 GHz
Options GENERAL PURPOSE GENERAL PURPOSE GENERAL PURPOSE
Panel mounting YES YES YES
reliability COMMERCIAL COMMERCIAL COMMERCIAL
Shell material STAINLESS STEEL STAINLESS STEEL STAINLESS STEEL
Total number of contacts 1 1 1
voltage standing wave ratio 1.24 1.17 1.17
Termination type SOLDER - SOLDER
Durability - 1000 Cycles 1000 Cycles
Installation option 1 - LOCKING LOCKING
Shell surface - GOLD GOLD
How to use PLL as master clock
I want to use PLL as the main clock. How should I set the parameters in the SysCtlClockSet function?...
dlyltm Microcontroller MCU
The tiger is coming!
...
onele Talking
SMBUS SLAVE address
Recently I need to write a program to read and write registers of SMBUS devices. It seems that all kinds of devices connected to SMBUS have their own fixed SLAVE ADDRESS. So I want to ask if there is ...
神童 Embedded System
About file system migration
I need help from all the experts: I am currently porting the file system of STM32, and I am using the petit FatFS file system. However, the system does not have the function of creating files, only op...
laiyangliuliu MCU
Low power relay control circuit
In battery-powered circuits or constant-current powered circuits, the sudden current surge that operates the relay can cause the power supply voltage to drop. This is the result of internal resistance...
pere Power technology
Does anyone know the common source of DC switches and AC switches below 60V?
I used an AC switch of 250V, 3A, with a nominal on-resistance of 50 milliohms, but the actual use environment is 5V/1A DC. Because the on-resistance of some switches increased to the ohm level during ...
seven561 Analog electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1669  810  1459  2892  2705  34  17  30  59  55 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190