MD100DER
Series
Dual Output, 1W SIP
Tightly Regulated
DC/DC Converters
Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features:
•
1W Output Power
•
Tight Regulation
•
Miniature SIP Case
•
1,000 VDC Isolation
•
12 Dual Output Models
•
>3.5 MHour MTBF
•
-40°C to +85°C Operation
•
LOW COST
Input
Parameter
Input Voltage Range
Input Filter
Conditions
5 VDC Input
12 VDC Input
24 VDC Input
Min.
4.75
11.40
22.80
Typ.
5.0
12.0
24.0
Max.
5.25
12.60
25.20
VDC
Units
Internal Capacitor
Conditions
For V
IN
Min to Max
For I
OUT
= 10% to 100%
See Note 2
10
50
±5 VDC Output Models
All Other Models
Conditions
60 Seconds
500 VDC
100 kHz, 1V
See Note 3
Conditions
Ambient
Min.
-40
-55
Free Air Convection
RH, Non-condensing
95
%
Min.
1,000
1,000
60
100
Typ.
+25
Max.
+85
+125
Min.
Typ.
Max.
±3.0
±0.25
±1.0
20
100
±0.03
Units
%
%
%
mV P - P
mV P - P
%/°C
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple (20 MHz)
Noise (20 MHz)
Temperature Coefficient
Output Short Circuit
Continuous (Autorecovery)
Momentary (1.0 Sec)
Typ.
Max.
Units
VDC
M
pF
kHz
Units
°C
°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
1.083 x 0.374 x 0.472 Inches (27.5 x 9.5 x 12.0 mm)
Non-Conductive Black Plastic (UL-94V0)
0.173 Oz (5.2g)
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Conditions
5 VDC Input
Input Voltage Surge (1 Sec)
Lead Temperature
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
Min.
3.5
Min.
-0.7
-0.7
-0.7
Typ.
Max.
9.0
18.0
30.0
300
°C
VDC
Typ.
Max.
Units
MHours
Units
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Weight
Reliability Specifications
Parameter
MTBF
Absolute Maximum Ratings
Parameter
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
Model Selection Guide
Input
Model
Number
MD105D-05ER
MD105D-09ER
MD105D-12ER
MD105D-15ER
MD112D-05ER
MD112D-09ER
MD112D-12ER
MD112D-15ER
MD124D-05ER
MD124D-09ER
MD124D-12ER
MD124D-15ER
5
5
5
5
12
12
12
12
24
24
24
24
Voltage
(VDC)
Nominal
Range
4.75 - 5.25
4.75 - 5.25
4.75 - 5.25
4.75 - 5.25
11.4 - 12.6
11.4 - 12.6
11.4 - 12.6
11.4 - 12.6
22.8 - 25.2
22.8 - 25.2
22.8 - 25.2
22.8 - 25.2
Current
(mA)
Full-Load No-Load
289
317
317
307
116
116
128
126
58
67
65
63
30
30
30
30
15
15
15
15
12
12
12
12
Voltage
(VDC)
www.micropowerdirect.com
Output
Efficiency
Current
(mA, Max)
Current
(mA, Min)
(%, Typ)
Fuse Rating
Slow-Blow
(mA)
±5.0
±9.0
±12.0
±15.0
±5.0
±9.0
±12.0
±15.0
±5.0
±9.0
±12.0
±15.0
±100
±56
±42
±33
±100
±56
±42
±33
±100
±56
±42
±33
±10.0
±6.0
±5.0
±4.0
±10.0
±6.0
±5.0
±4.0
±10.0
±6.0
±5.0
±4.0
69
63
63
65
72
62
65
66
72
62
64
66
600
600
600
600
250
250
250
250
150
150
150
150
Notes:
1. Operation at no load will not damage these units. However, they may not
meet all specifications.
2. These converters will operate without external components. However,
when measuring output ripple, it is recommended that an external
ceramic capacitor be placed from the +Vout pin to the -Vout pin for
single output units and from each output to common for dual output
units. An input capacitor will enhance stability over temperature and
input line variations. For applications requiring very low output noise
levels, a simple LC filter, as shown in the connection diagram below,
should be effective. Recommended component values are given in
the table below the diagram.
Derating Curve
V
IN
5 VDC
12 VDC
24 VDC
C
1
4.7
µF/50V
4.7
µF/50V
1.0
µF/50V
L
1
4.7 - 10
µH
4.7 - 10
µH
4.7 - 10
µH
V
OUT
±5 VDC
±9 VDC
±12 VDC
±15 VDC
L
2
, L
3
4.7 - 10
µH
4.7 - 10
µH
4.7 - 10
µH
4.7 - 10
µH
C
2
, C
3
10
µF
4.7
µF
2.2
µF
1.0
µF
Mechanical Dimensions
3. The typical switching frequency for the
MD105D-15ER
is 250 kHz. For the
MD124D-15ER
the typical switching frequency is 300 kHz.
4. It is recommended that a fuse be used on the input of a power supply for
protection. See the Model Selection table above for the correct rating.
Pin Connections
Pin
1
2
7
9
10
Function
+V
IN
-V
IN
+V
OUT
-V
OUT
Common
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.02 (
±
0.50)
•
Pin 1 is marked by a “dot” or indentation on the unit
FAX: (781) 344-8481
•
TEL: (781) 344-8226
•
E-Mail: sales@micropowerdirect.com