DC-AC INVERTER UNIT
PS-DA0412-210(S)
(25 W QUAD OUTPUTS)
DESCRIPTION :
This low profile DC to AC Inverter is developed for quad lamps.
Optimized for Sharp Display: LQ190E1 LW02
(PRELIMINARY INFORMATION)
APPLICABLE LCD:
15 to 21 inches quad lamp type
Lamp Voltage 750 Vrms
Lamp Current 4 x 7.0 mArms
Lamp Start Up Voltage 1.800 Vrms (Vin : 12 Vdc)
FEATURES :
Remote ON/OFF
Open Lamp Detection
Internal PWM Controller with wide dimming function
High Efficiency
RoHS compliant (S)
TEMPERATURE & HUMIDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
DIMENSIONS :
LxWxH
-10°C ~ +60°C
-20°C ~ +85°C
95 %RH max
200 x 44 x 12 mm
Unit : mm
Weight :38,4 (g) typ.
Note: Please use plastic screw in case of a non-insulating mounting base!
Components
No.
1
2
3
Part Description
PCB
Connector CN1
Connector CN2 ~ CN5
Qty.
1
1
4
Material
UL94V-0 (FR-4 or CEM-3)
B8B-PH-K
SM02(8.0)B-BHS-1-TB
Note
t=1m m
JST or equal
JST or equal
Input side CN1:
Pin No. Symbols
Vin
CN 1-1;2;3
GND
CN 1-4;5;6
Vbr
CN 1-7
Vrmt
CN 1-8
Ratings
10.8 ~ 13.2 Vdc
0 ~ 3.0 Vdc
0 ~ 0.5 = OFF / 3.3 ~ Vin = ON
Output side CN2 ~ CN5:
Pin No.
Symbols
Ratings
Vhigh
750 Vrm s (7.0 m Arm s )
CN 2-1
N.C.
-
CN 2-2
Vlow
(GND)
CN 2-3
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Page (1)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Version 1.0, 11th January 2008
All specifications are subject to change without notice.
DC-AC INVERTER UNIT
PS-DA0412-210(S)
(25 W QUAD OUTPUTS)
ELECTRICAL CHARACTERISTICS :
(PRELIMINARY INFORMATION)
Conditions
Parameters
Symbols
Vrmt
Vin (V)
Tu (°C)
(V)
Iout
12±1.2 5±0.25 0 ~ +50
Output Current
Iout
12±0.6 5±0.25 0 ~ +50
Output Current
Iin
12±1.2 5±0.25 0 ~ +50
Input Current
F
12±1.2 5±0.25 0 ~ +50
Frequency
11.4
5±0.25 0 ~ +50
Open Circuit Voltage
Vopen
Note 1 :
Specification
Min.
6.0
-
50
1.650
Typ.
7.0
18.0
1.67
55
1.800
Max.
8.0
-
2.17
60
3.000
Unit
m Arm s
%
Adc
kHz
Vrm s
Note
V br = 0 V dc
V br = 3.0 V dc
Please keep minimum of 2mm clearance (all directions) between inverter high voltage area as marked
on mechanical drawing and any conductors.
TEST CIRCUIT :
SW 1
a
b
Operation of unit
Operation
Non operation
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
Info@Power-Systems.de
Page (2)
Address: Hauptstr. 48 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 800
Version 1.0, 11th January 2008
All specifications are subject to change without notice.