EEWORLDEEWORLDEEWORLD

Part Number

Search

27-002.5-183DHT

Description
Interconnection Device, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size227KB,3 Pages
ManufacturerAries Electronics
Environmental Compliance
Download Datasheet Parametric View All

27-002.5-183DHT Overview

Interconnection Device, ROHS COMPLIANT

27-002.5-183DHT Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
package instructionROHS COMPLIANT
Reach Compliance Codecompli
ECCN codeEAR99
Other features94V-0
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
• For RoHS applications for Lead-Free Soldering use HT Cable
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
Optional Suffix:
“HT”=High temperature cable insulation
Optional Suffix:
“TL” = Tin/Lead Plating
Optional Suffix:
“P”=Polarization stripe included
Cable Length: “L” in inches
Min. Cable Length = 2.00” (-002)
2” = -002-
2.5” = -002.5-
2.25” = -002.25-
2.125” = -002.125-
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
Bend Options:
“A” = Both ends bent 90°, same direction
“B” = One male end bent 90°
“C” = Both ends bent 90°, opposite direction
“D” = One female end bent 90°
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-183APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
http://www.arieselec.com • info@arieselec.com
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
Bristol, PA
USA
TEL:
(215) 781-9956
FAX:
(215) 781-9845
abc
11019
REV.K
Page
1 of 3

Recommended Resources

[TI's first low-power design competition] [Intelligent Internet Era] - Serial port debugging, I will do it step by step
[i=s]This post was last edited by zidantou on 2014-12-23 13:56[/i] [align=left] A very user-friendly feature of 430FR5969 is that it has its own virtual serial port just like the G2553 LunchPad[/font]...
zidantou Microcontroller MCU
How to connect the pressure sensor? I saw it connected like this on a sample board, but I always feel like something is wrong.
How to connect the pressure sensor? I saw it connected like this on a sample board, but I always feel like something is wrong....
helloxieyu Microcontroller MCU
Ask about code optimization in Keil C
What are some good ways to optimize the code size in Keil C? What is the best order for defining local variables in a function? Why does a different order of some codes in a function cause a large cha...
septem Embedded System
Need advice from experts on single chip microcomputer
I have a question. The 8-bit P2 port of the 51 single-chip microcomputer is connected to the 8-segment pins of the digital tube. The bias of the digital tube is controlled by the other two pins, a tot...
xiaobao Analog electronics
My experience in monitoring management interview
Some time ago, I participated in an interview for monitoring management. I was a little nervous at first, but later I felt that the process was quite simple (but experience is required). [b]There are ...
小瑞 Industrial Control Electronics
Introduction to Electrical Engineering with Illustrations
Illustrated Introduction to Electrical Engineering 1.2...
wangwei20060608 RF/Wirelessly

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 319  1325  1745  968  2258  7  27  36  20  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号