EEWORLDEEWORLDEEWORLD

Part Number

Search

56.44.9.024.2051

Description
Electromechanical Relay, 4PDT, 26.4VDC (Coil), 1300mW (Coil), Random, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

56.44.9.024.2051 Overview

Electromechanical Relay, 4PDT, 26.4VDC (Coil), 1300mW (Coil), Random, AC/DC Output

56.44.9.024.2051 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
body width27.7 mm
body height37.1 mm
Body length or diameter40.8 mm
Coil operating voltage (DC)20.4 V
Coil power1300 mW
Coil resistance490 Ω
Maximum coil voltage (DC)26.4 V
Nominal coil voltage24 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts5000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life100000 Cycle(s)
End contact materialSilver Cadmium Oxide
Input switching control typeRandom
Number of terminals14
operating hours10 ms
PCB hole count14
physical size40.8mm x 27.7mm x 37.1mm
GuidelineCSA; IMQ; PCT; UL; VDE
Relay function4PDT
release time4 ms
Terminal length0.0043 inch
Termination typeSOLDER
Base Number Matches1
56
56 Series - Miniature power relays 12 A
Features
Plug-in - 12 A Power relay, 2 & 4 pole
Flange mount option -
(Faston 187, 4.8x0.5 mm termination)
AC coils & DC coils
Lockable test button and mechanical flag indicator
Cadmium Free contacts (standard version)
Contact material options
96 series sockets
Coil EMC suppression
Accessories
European Patent
SERIES
56.32/56.34
56.32-0300
Plug-in / PCB Relays
1
2 or 4 pole changeover contact
Plug-in/Faston 187
2 pole normally open contact
(≥1.5 mm gap)
Plug-in/Faston 187
56.32
56.32-0300
56.34
* For 4 CO (4PDT) only.
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
XI-2013, www.findernet.com
56.32
56.34
56.32-0300
2 CO (DPDT)
A
VA
VA
kW
A
12/20
250/400
3,000
700
0.55
4 CO (4PDT)
2NO (DPST-NO) -
≥1.5mm
gap
12/20
250/400
3,000
700
0.55
12/1/0.5
500 (10/5)
AgNi
Rated voltage/Maximum switching voltage V AC
12/0.5/0.25
500 (10/5)
AgNi
mW (V/mA)
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
V AC
°C
8/3
4
1.5/1
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400*
6 - 12 - 24 - 48 - 60 - 110 - 125 - 220
2/1.3
(0.8…1.1)U
N
(0.8…1.1)U
N
(0.85…1.1)U
N
0.8 U
N
/0.6 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
100 · 10
3
10/4
5
1,000
–40…+70
RT I
1.5/—
(0.85…1.1)U
N
0.85 U
N
/—
0.2 U
N
/—
20 · 10
6
/—
100 · 10
3
8/4
4
2,000
–40…+70
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals
(according to type)
DS-5 delayed interruption problem
[size=5] Verilog code written under Quartus13.1. [/size] module test( input wire sclk, //clock signal input wire rst_n, //reset signal input wire cs, //chip select signal input wire w_en, //write enab...
三个太阳在路上 FPGA/CPLD
How to use CreateFile to get the serial port handle under wince
00 00 05 00 00 00 10 01 00 00 00 4B 00 00 00 00 08 00 00 0. [HKEY_LOCALMACHINE/drivers/BuildIn/Serial_cmd] (Default): (value not set) Dll: com165550.Dll Tsp: Unimodem.dll IoBase: 2926575616 Irq: 19 Io...
luoxinmjun520 Embedded System
.Infrared decoding code based on TC9012
#includereg52.h#define uint unsigned int #define uchar unsigned char uchar irtime;sbit beep=P3^6;sbit ir_pin=P3^2;uchar irreciveok;uchar irdata[33];uchar bitnum;uchar ircode[4];uchar irprook;uchar dis...
wateras1 MCU
20 analog circuits that electronic engineers should master, very classic, worth downloading! !
20 analog circuits that electronic engineers should master Very classic, worth downloading!!...
pjx001 Analog electronics
Is there Windows XP Embedded?
[color=#FF0000]Is there Windows XP Embedded? Are there any related learning materials and development boards for sale? How much do they cost? [/color] [color=#FF00FF][size=24px]I strongly[/size] reque...
lhzisname Embedded System
Application of PLC and WINCC configuration software in automatic control
The ring cooling ash unloading system of the sintering workshop of a certain factory unloads the small particles of ore and dust blown out by the blower in the ring cooling process onto the ring cooli...
frozenviolet Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2248  2720  1124  463  975  46  55  23  10  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号