EEWORLDEEWORLDEEWORLD

Part Number

Search

2158-S5-27-10

Description
Card Edge Connector, 116 Contact(s), 2 Row(s), Female, Right Angle, Solder Terminal
CategoryThe connector    The connector   
File Size151KB,2 Pages
ManufacturerECS
Websitehttp://www.ecsxtal.com/
Download Datasheet Parametric View All

2158-S5-27-10 Overview

Card Edge Connector, 116 Contact(s), 2 Row(s), Female, Right Angle, Solder Terminal

2158-S5-27-10 Parametric

Parameter NameAttribute value
Objectid1970359411
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOLARIZED
Connector typeCARD EDGE CONNECTOR
Contact point genderFEMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Mixed contactsNO
Installation methodRIGHT ANGLE
Installation typeBOARD
Number of rows loaded2
OptionsGENERAL PURPOSE
Terminal pitch3.18 mm
Termination typeSOLDER
Total number of contacts116
UL Flammability Code94V-0
CC
S
2100 Series Card Edge Connector
.125” X .250” Contact Spacing
Features
Extra large chamfered entry
Conforms to Bell-core spec TR-TSY-00078
Extended card scoops available
Replaceable contacts
Molded in polarization available between
contact, or on contact position.
• De-population of contacts per
customer specification.
• Available in selective gold plate at contact point
• Many other custom options available, including,
but not limited to:
• Single or Both Ends Open
• Shorting Contacts
Specifications
Insulator Material: Glass filled polyester, type PBT,
94 V-O, UL Rated.
Contact Material: Phosphor Bronze Alloy
Contact Plating: Gold and/or Tin over .000050” Nickel,
(See Contact Plating Options).
Current Rating:
3 amp at 30°C
Contact Resistance:
Contact to Daughter Card:
10 m
W
max.
Insulation Resistance:
5000 M
W
min.
Dielectric Withstand Voltage:
1500 V AC
Daughter Board Insertion Force:
16 oz max. per contact pair
when tested with a .071” thick
gage.
Daughter Board Withdrawal Force:
1 oz min. per contact pair
when tested with a .054” thick
gage.
Operating Temperature:
-54
B
C to +125
B
C
R
C
NO. OF CONTACTS
R
A
Recognized under the recognized component
Program of Underwriters Laboratories, Inc.
File Numbers: E146967 and E176234
POS. / CONTACTS
06/12
10/20
12/24
16/32
18/36
20/40
22/44
25/50
28/56
30/60
36/72
38/76
40/80
43/86
50/100
51/102
56/112
60/120
A
1.011 [25.68]
1.511 [38.38]
1.761 [44.73]
2.261 [57.43]
2.511 [63.78]
2.761 [70.13]
3.011 [76.48]
3.386 [86.00]
3.761 [95.53]
4.011 [101.88]
4.761 [120.93]
5.011 [127.28]
5.261 [133.63]
5.626 [143.15]
6.511 [165.38]
6.636 [168.55]
7.261 [184.43]
7.761 [197.13]
B
0.875 [22.23]
1.375 [34.93]
1.625 [41.28]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
2.875 [73.03]
3.250 [82.55]
3.625 [92.08]
3.875 [98.43]
4.625 [117.48]
4.875 [123.83]
5.125 [130.18]
5.500 [139.70]
6.375 [161.93]
6.500 [165.10]
7.125 [180.98]
7.625 [193.68]
C
0.625 [15.88]
1.125 [28.58]
1.375 [34.93]
1.875 [47.63]
2.125 [53.98]
2.375 [60.33]
2.625 [66.68]
3.000 [76.20]
3.375 [85.73]
3.625 [92.08]
4.375 [111.13]
4.625 [117.48]
4.875 [123.83]
5.250 [133.35]
6.125 [155.58]
6.250 [158.75]
6.875 [174.63]
7.375 [187.33]
Dimensions are in inch [mm]
For reference only, can go 1 through 60 positions.
MOUNTING STYLE
.250
[6.35]
.180
[4.57]
.610
[15.49]
.250
[6.35]
1
= Clearance Hole
2
= #4-40 Threaded Insert
3
= Flush Mount
4
= #4-40 Threaded Insert
5
= No Mounting Ear
6
= Side Mounting
WWW.ECSCONN.COM
Design of virtual test system for DC/DC power supply module
In recent years, with the increasing requirements for the diversity and complexity of power supply products, how to scientifically and quickly detect their performance and indicators has become a majo...
mtbf Power technology
How can I programmatically operate an ActiveSync USB connection on a PC? Enumerate the USB device and operate it as a normal USB device? Or RAPI?
How can I programmatically operate an ActiveSync USB connection on a PC? Enumerate the USB device and operate it as a normal USB device? Or RAPI?...
jlj402343660 Embedded System
Help you quickly develop emwin
First, let's look at the renderings of the emwin simulator.It is very easy to use. Delete the code in GUIDEMO_Start.c, and then copy the code generated by guibuilder to GUIDEMO_Start.c. Click run and ...
weizhongc stm32/stm8
TI DC/DC power supply dual-channel driver UCC27201 power-on problem solution
The dual-channel driver UCC27201 with floating ground function is often used in isolated DC/DC power supplies. In actual applications, it is found that in some scenarios, its HO pin will generate fals...
qwqwqw2088 Analogue and Mixed Signal
Which brand of PLC has the best pulse command and good effect?
As for single-channel pulse, which brand of PLC has the best pulse command and the best effect? (Delta, LG, Mitsubishi, Siemens, Schneider, Omron...) EMERSON has ABS (current value reading instruction...
eeleader Industrial Control Electronics
How to solve the "_FORTIFY_SOURCE" problem when compiling Android code in Ubuntu 12.04 (gcc downgrade)
[align=left][color=rgb(51, 51, 51)][font=Verdana, Arial, Helvetica, sans-serif][size=13.6px]一、编译报错[/size][/font][/color][/align][align=left][color=rgb(51, 51, 51)][font=Verdana, Arial, Helvetica, sans...
gooogleman Linux and Android

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1546  418  1395  786  2078  32  9  29  16  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号