Cemented Wirewound Resistors

AC.. Series
www.vishay.com
Vishay Draloric
Cemented Wirewound Resistors
FEATURES
• All welded construction
• Ceramic core
• Non-flammable cement coating
• Tinned copper-clad iron leads
(for axial parts)
• High power dissipation in small volume
• Ideal for pulse application
• Material categorization: For definitions of compliance
please see
www.vishay.com/doc?99912
STANDARD ELECTRICAL SPECIFICATIONS
MODEL
AC01
AC03
AC04
AC05
AC07
AC10
(2)
POWER
RATING
P
40 °C
W
1
3
4
5
7
10
POWER
RESISTANCE RANGE
(1)
RESISTANCE RANGE
(1)
RESISTANCE RANGE
(1)
LIMITING
RATING
TOLERANCE
VOLTAGE
P
70 °C
TCR =
TCR =
±%
TCR= ± 100 ppm/K
U
max.
- 10 ppm/K to - 80 ppm/K 100 ppm/K to 180 ppm/K
W
0.9
2.5
3.5
4.7
5.8
8.4
P
P
P
P
P
P
x
x
x
x
x
x
R
R
R
R
R
R
0.10 to 33
0.10 to 390
0.10 to 620
0.10 to 910
0.10 to 1.5K
0.22 to 560
36 to 2.4K
430 to 3.3K
680 to 6.8K
1K to 10K
1.6K to 15K
620 to 27K
n/a
3.6K to 5.1K
n/a
n/a
n/a
n/a
5
5
5
5
5
5
Notes
(1)
Resistance value to be selected for ± 5 % from E24
(2)
AC03 WSZ:
P
40 °C
= 1.8 W;
P
70 °C
= 1.5 W
PART NUMBER AND PRODUCT DESCRIPTION
Part Number: AC03000001509JAC00
A
MODEL
C
0
3
VARIANT
0
0
0
0
0
1
5
0
9
J
A
C
0
0
TCR/MATERIAL
0
= Standard
VALUE
3 digit value
1 digit
multiplier
MULTIPLIER
7
= *10
-3
8
= *10
-2
9
= *10
-1
0
= *10
0
1
= *10
1
2
= *10
2
5
= 10
-4
TOLERANCE PACKAGING
CODE
CODE
J
= ± 5.0 %
(See
Packaging
table)
SPECIAL
The 5 digit BV number will be
encoded using a 36 character
code. This code contains
numbers 0...9 and letters
A...Z
(36 characters total) and
allows to encode at least 46
655 five digit BV numbers.
00
= Standard
AC01000
= AC01
AC03000
= AC03
AC04000
= AC04
AC05000
= AC05
AC07000
= AC07
AC10000
= AC10
0
= Neutral
1
= RT
2
= SWI =
Special winding
(3)
3
= DK SP 20 mm
(4)
4
= DK LP 33 mm
(4)
5
= DK LP 17.8 mm
(4)
6
= NI = Non inductive
(7)
7
= DK LP 25.4 mm
(4)
9
= WSZ 6720
8
= DK SP 25.4 mm
Z
= Value overflow
(Special)
C
= E/K 25.4 mm
(4)
Product Description: AC03 15R 5 % AC
AC03
MODEL
(5)
Notes
(3)
Special winding on request
(4)
Other dimensions and variants on request
(5)
See “Part Number and Product Description”
(6)
See “Packaging Table”
(7)
Resistance range on request
Revision: 10-Jun-13
Document Number: 28730
1
For technical questions, contact:
ww1resistors@vishay.com
THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT
ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
15R
VALUE
(5)
5%
TOLERANCE CODE
(5)
AC
PACKAGING
DESCRIPTION
(6)
Wen's Oscillation Problem
Is the current-type op amp or the voltage-type op amp used for the Wen oscillation? The relevant information only talks about the peripheral parameters, and there is not much introduction about the op...
S3S4S5S6 Analog electronics
Lithium battery balancing
[color=#000]I am currently trying to use the Chuck circuit to perform active balancing of two batteries. I built the circuit using PSPICE, but the result is not right. The voltages of the two batterie...
dianzirainy Integrated technical exchanges
Copter_accessory_DIY based on Renesas R7F0C80212] (V) Twists and turns - Summary and demonstration video
[i=s]This post was last edited by tziang on 2014-9-28 13:01[/i] [align=left]2014-9-27[/align] [align=left]Things have happened[/align] [align=left]Seeing that the event has been postponed, it is not r...
tziang Renesas Electronics MCUs
Fluke-279FC - "Basic Skills"
[i=s]This post was last edited by tianshuihu on 2016-8-30 18:52[/i] [color=rgb(0, 0, 0)][font=simsun]The Fluke-279FC is known as "the first test tool to combine a full-featured true RMS (TRMS) digital...
tianshuihu Test/Measurement
what do I do
[color=#444444][font=Tahoma,]I just changed to a new company and did several projects. The last one, what is called wireless, [/font][/color] [color=rgb(68, 68, 68)][font=Tahoma,]used a module, YYW_M2...
chenbingjy Talking
Windows embedded ce 6.0 cannot load the network card driver
I always can't load the network card driver with the new x86 kernel cut from Windows embedded ce 6.0. The network card is Intel82559. Please help!...
jsytdx Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 753  467  1192  10  2177  16  10  25  1  44 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号