MPM-03MM
Series
Miniature 1 x 1 Inch
3W, Single Output
AC/DC Power Supplies
Electrical Specifications
Key Features:
•
3W Output Power
•
Miniature 1 x 1 Inch Case
•
Universal 85-264 VAC Input
•
EN 60950 Approved
•
Six Standard Models
•
Meets EN 55022 B
•
Meets IEC Safety Class II
•
>1.20 MHour MTBF
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Input Current
Inrush Current, See Note 1
No Load Power Consumption
Conditions
Min.
Typ.
85
120
47
See Model Selection Guide
115 VAC
230 VAC
See Note 2
Max.
264
370
63
15.0
25.0
150
Max.
Units
VAC
VDC
Hz
A Pk
mW
Units
Output
Parameter
Output Voltage
Output Current
Output Voltage Accuracy
Line Regulation
Load Regulation
Ripple & Noise (20 MHz)
Hold-Up Time
Temperature Coefficient
Over Voltage Protection
Overshoot
Short Circuit Protection, See Note 4
Overload Protection
Conditions
Min.
Typ.
See Model Selection Guide
See Model Selection Guide
V
IN
= Min to Max
I
OUT
= 0% to 100%
115 VAC
See Note 3
8.0
125
±0.05
190
5.0
±2.0
±1.0
±1.0
70
%
%
%
m V
P-P
mS
%/°C
%V
OUT
%V
OUT
%W
Continuous (Auto-Recovery)
See Note 5 135
150
Conditions
Input to Output, 60S
500 VDC
Min.
3,000
100
Typ.
Max.
General
Parameter
Isolation Voltage
Isolation Resistance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFM
Voltage Dips
Interruptions
Units
VAC
M
kHz
65
Standard
EN 55014, EN 55024
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
EN 61000-4-11
EN 61000-4-11
Conditions
Criteria
A
A
A
A
A
A
A
B
Level
Class B
Class B
±8 kV Air
10V/m
±2 kV
±1 kV
10 Vrms
30A/m
30% 10 mS
95% 5,000 mS
Units
°C
°C
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Min.
Typ.
Max.
-25
+25
+70
-40
+85
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing
95
Ambient
Physical
Case Size
Case Material
Weight
See Mechanical Diagram (Page 2)
Non-Conductive Black Plastic (UL94-V0)
0.59 Oz (17.4g)
Conditions
Min.
Typ.
MIL HDBK 217F, 25°C, Gnd Benign 1.20
EN 60950
IEC 60536 Class II
Max.
Units
MHours
Reliability Specifications
Parameter
MTBF
Safety Standards
Safety Class
www.micropowerdirect.com
Model Selection Guide
Model
Number
MPM-03S-03MM
MPM-03S-05MM
MPM-03S-09MM
MPM-03S-12MM
MPM-03S-15MM
MPM-03S-24MM
Input
Current
(mA Typ)
www.micropowerdirect.com
Output
Current
(mA)
Max.
900
600
333
250
200
125
Min.
0.0
0.0
0.0
0.0
0.0
0.0
Peak
1,170
780
430
320
260
160
Fuse
Efficiency Capacitive
Rating
Load
(%, Typ)
(µF Max) Slow-Blow
(mA)
70
72
77
78
78
78
1,200
820
470
330
270
180
1,000
1,000
1,000
1,000
1,000
1,000
Other outputs may be available
Contact the factory for details at:
sales@micropowerdirect.com
Voltage
(VDC)
115
VAC
62
61
57
56
56
56
3.3
5.0
9.0
12.0
15.0
24.0
Notes:
1
.
Inrush current is given for a cold start at 25°C.
2. No load power consumption meets the standby power consumption limits in
the European ERP Directive 2009/125/EC.
3. Over voltage protection is provided by a zener diode clamp.
4. Output short circuit protection is provided by a “hiccup mode” circuit. The
unit recovers automatically when the fault condition is removed.
5. Output overload protection is provided by a fold back current limiting circuit
with auto-recovery. A long-term overload could damage the unit.
6. Operation at no-load will not damage these units. However, they may not meet
all specifications.
7. Peak load is specified as lasting <30s with a maximum duty cycle of 10%
The average power should not exceed the maximum power rating.
8. It is recommended that an external slow blow fuse also be used on the input
for protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Pin Connections
Pin
1
2
3
4
5
Function
AC-Neutral
AC-Line
No Connection
-V
OUT
+V
OUT
Notes:
•
All dimensions are typical in inches (mm)
•
Tolerance x.xx =
±
0.02 (
±
0.25)
MicroPower Direct
We Power Your Success - For Less!
292 Page Street Ste D Stoughton, MA 02072
•
TEL: (781) 344-8226
•
FAX: (781) 344-8481
•
E-Mail: sales@micropowerdirect.com