LFV330-DAGBVXMC0500
LFV300
LEVEL SENSORS
Online data sheet
LFV330-DAGBVXMC0500 | LFV300
LEVEL SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Ordering information
Type
LFV330-DAGBVXMC0500
Other models and accessories
www.sick.de/LFV300
Part no.
6039736
Illustration may differ
Detailed technical data
Features
Medium
Measurement
Probe length
Process pressure
Process temperature
Fill material density
ATEX approval
Type examination
GOST approval
WHG approval
Fluids
Switch
500 mm
–1 bar ... 64 bar
–50 °C ... +150 °C
0.5 g/cm³ ... 2.5 g/cm³
ATEX II 1/2G, 2G Ex d IIC T6
TÜV 09 ATEX 372527 X
✔
✔
Performance
Accuracy of sensor element
Repeatability
Viscosity
Response time
± 2 mm
≤ 1 mm
0.1 mPas ... 10,000 mPas
500 ms
Electronics
Power consumption
Initialization time
VDE protection class 1
Electrical connection
Supply voltage
Hysteresis
Output current
Inductive load
Capacitive load
< 4.2 mA
< 3 s
✔
M20 x 1.5
Non-contact switch: 20 V AC/DC ... 253 V AC/DC
2 mm
< 400 mA
1 H
100 nF
2
FLUID SENSORS | SICK
Online data sheet | 2015-12-07 11:19:05
Subject to change without notice
LFV330-DAGBVXMC0500 | LFV300
LEVEL SENSORS
Enclosure rating
Temperature drift
IP 66 / IP 67
0,03 mm/K
Mechanics
Wetted parts
Process connection
Housing material
Sensor material
Stainless steel 316L (optional Ra ≤ 0.8 μm)
G ¾ A PN 64 / 1.4404
Aluminum
Stainless steel 1.4404
Ambient data
Ambient operating temperature
Ambient storage temperature
–40 °C ... +70 °C
–40 °C ... +80 °C
Dimensional drawing
(Dimensions in mm (inch))
LFV330
18.5
(0.73)
36
(1.42)
32 (G 3/4 A, 3/4" NPT)
41 (G 1 A, 1" NPT)
L
G 3/4 A,
3/4" NPT
G 1 A,
1" NPT
L
1
2
L
57
(2.24)
3
50
(1.97)
ø 33.7
(1.33)
19
(0.75)
L
L
4
5
6
7
① Thread
② Tri-Clamp
③ DN
25 cone
④ Bolting
D 40
⑤ Flange
⑥ Gas-tight
leadthrough
⑦ Temperature
adapter
2015-12-07 11:19:05 | Online data sheet
Subject to change without notice
34
(1.34)
178
(7.01)
FLUID SENSORS | SICK
3
LFV330-DAGBVXMC0500 | LFV300
LEVEL SENSORS
A
B
C
D
E
F
H
I
J
K
L
M
N
O
P
Q
R
S
T
Marking on the welded flange
1
① Marking
Connection diagram
Contactless electronic switch connection diagram
1 2
AC L1 N
DC
+ -
- +
Connection type
LFV300 Contactless electronic switch - electronic module
1
2
3
4
FLUID SENSORS | SICK
1
2
Online data sheet | 2015-12-07 11:19:05
Subject to change without notice
LFV330-DAGBVXMC0500 | LFV300
LEVEL SENSORS
Instruction for installation
Inflowing medium
Characteristic curve
Influence of the process temperature on the switching point
1
4
10 ( 25/64")
8 ( 5/16")
6 ( 15/64")
4 ( 5/32")
3
2 ( 5/64")
0
-2 (-5/64")
-4 (-5/32")
-6 (-15/64")
-8 (-5/16")
-10 (-25/64")
0 °C
50 °C
100 °C
150 °C
200 °C
250 °C
2
① Shifting
of the switching point in mm (in)
② Process
temperature in °C (°F)
③ Switching
point at reference conditions (notch)
④ Tuning
fork
Recommended accessories
Other models and accessories
www.sick.de/LFV300
Brief description
Type
Part no.
Flanges
Welded flange/welded connector, DIN11851-1, DN25 / PN40, Stainless steel 1.4404
BEF-FL-851D25-LFV2
5321527
Welded flange/welded connector, process connection G 1, Stainless steel 1.4404
BEF-FL-
GEWG10-LFV2
4054605
2015-12-07 11:19:05 | Online data sheet
Subject to change without notice
FLUID SENSORS | SICK
5