EEWORLDEEWORLDEEWORLD

Part Number

Search

LDC-120-1050x

Description
150W Output Power
File Size1MB,4 Pages
ManufacturerMicroPower Direct ( MPD )
Websitehttp://www.micropowerdirect.com
Download Datasheet View All

LDC-120-1050x Overview

150W Output Power

LDC-120
Series
Compact, LED, 150W
Constant Current
AC/DC Power Supply
Key Features:
150W Output Power
UL 8750 Approved
Constant Current Output
Active PFC
90 - 305 VAC Input
IP65 / IP67 Rated
Meets EN 55015, EN 61547
Dimming Function
>50 kHour Life Expectancy
Lightning Surge Protection
Over Volt/Temp Protection
Power Factor Correction
Total Harmonic Distortion (THD)
Turn On Delay, See Note 3
Leakage Current
Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Input
Parameter
Input Voltage Range
Input Frequency
Inrush Current, See Note 1
Input Current
Conditions
Min.
90
127
47
230 VAC
115 VAC
230 VAC
264 VAC
0.98 @ 115 VAC
0.95 @ 230 VAC
0.93 @ 264 VAC
See Note 2
115 VAC
230 VAC
277 VAC
Conditions
V
IN
= Min to Max
See Note 4
Min.
Typ.
Max.
305
431
63
Units
VAC
VDC
Hz
A Pk
A
75
1.60
0.80
0.70
10
1.5
0.5
0.75
Typ.
±5.0
±1.0
2.0
±5.0
Max.
%
S
mA
Units
%
%
V
P-P
%
mS
°C
%
IOUT
Units
VAC
Output
Parameter
Output Current Accuracy
Line Regulation
Ripple & Noise (20 MHz)
Output Ripple Current
Hold-Up Time
Over Temperature Protection
Short Circuit Protection
Overload Protection
115 VAC 12.0
±10%, Autorecovery
85
Continuous (Autorecovery)
Autorecovery
95
Conditions
Min.
Input to Output 3,750
Input to FG 2,000
Output to FG
500
Input to Output
Input to FG 100 M
Output to FG
Typ.
107
Max.
General
Parameter
Isolation Voltage, 60S
Insulation Resistance
EMI Characteristics
Parameter
EMI
EMS
Surge
/ 500 VDC / 25°C / 70% RH
Standard
EN 55015; EN 6100-3-2, -3; FCC Part 18; CNS 14115; GB 17743
EN 61547; EN 61000-4-2,-3, -4, -5, -6, -8, -11; GB 17625.1
10 kV (L/N - FG), 5 kV (L-N)/1.2 x 50
µS
Min.
Typ.
Max.
-40
+25
+70
-40
+85
Free Air Convection (See Derating Curve on Page 2)
RH, Non-condensing
95
Ambient
Conditions
Units
°C
°C
%
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T:
(781) 344-8226
F:
(781) 344-8481
E:
sales@micropowerdirect.com
W:
www.micropowerdirect.com
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Weight
See Mechanical Diagrams (Page 4)
32.1 Oz (950g)
Conditions
Min.
Typ.
Max.
Units
MIL HDBK 217F, 25°C, Gnd Benign
220
kHours
See Note 5
50
kHours
UL 8750 Approved, Meets EN 61347, GB 19510.1, GB 19510.14
5 - 500 Hz, 1G , 1 Oct/Min, 2 Cycles, Period for 75 Min. Each Along X, Y, & Z Axis
Reliability Specifications
Parameter
MTBF
Life Expectancy
Safety Standards
Vibration
www.micropowerdirect.com
How do companies control the departure of technical developers who hold core secrets (such as SLE4442 card passwords)?
When technical developers who have access to core secrets (e.g., those working in smart meter factories who have access to the SLE4442 card passwords used by the company's smart meters for electricity...
一沙一世 stm32/stm8
MSP430F42x0 ,MSP430F241x, MSP430F261x code examples
Here are some code examples for MSP430F42x0, MSP430F241x, and MSP430F261x found on TI's official website....
恭梧溪 Microcontroller MCU
You are invited to attend the Embedded System Elite Forum on January 30 (free)!
At the end of 2009, embedded technology was reviewed. Experts and scholars in the embedded industry gathered together. The three-month search for embedded programming masters by the "Top-E Cup" finall...
topeca FPGA/CPLD
Switching lithium battery charging management chip HB6293
l Suitable for single or dual-cell Li-ion/Li-polymer high efficiency current mode PWM charger l 0.5% charging voltage control accuracy l Programmable charging current control l Constant voltage chargi...
htdzxiaoyao Power technology
High salary recruitment of MCU engineers
Harbin Hongtai Weiye Technology Co., Ltd. Salary: 12,000-20,000 yuan (80% of the probationary salary, regular employment within one month) Education requirements: Bachelor degree Recruitment position:...
hongtai Recruitment
What is the definition of electrical clearance?
Electrical clearance refers to the shortest straight-line distance between two conductive parts or between a conductive part and the ground, and is mainly used for center point protection of transform...
eeleader Industrial Control Electronics

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2387  2918  1556  2051  1168  49  59  32  42  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号