EEWORLDEEWORLDEEWORLD

Part Number

Search

LTC2978A_15

Description
8-Channel PMBus Power System Manager Featuring Accurate Output Voltage Measurement
File Size906KB,82 Pages
ManufacturerLinear ( ADI )
Websitehttp://www.analog.com/cn/index.html
Download Datasheet View All

LTC2978A_15 Overview

8-Channel PMBus Power System Manager Featuring Accurate Output Voltage Measurement

FEATURES
n
n
n
n
n
n
n
LTC2978A
8-Channel PMBus Power
System Manager Featuring Accurate
Output Voltage Measurement
DESCRIPTION
The
LTC
®
2978A
is an 8-channel Power System Manager
used to sequence, trim (servo), margin, supervise, man-
age faults, provide telemetry and create fault logs. PMBus
commands support power supply sequencing, precision
point-of-load voltage adjustment and margining. DACs use
a proprietary soft-connect algorithm to minimize supply
disturbances. Supervisory functions include overvoltage
and undervoltage threshold limits for eight power supply
output channels and one power supply input channel, as
well as over and under temperature limits. Programmable
fault responses can disable the power supplies with optional
retry after a fault is detected. Faults that disable a power
supply can automatically trigger black box EEPROM storage
of fault status and associated telemetry. An internal 16-bit
ADC monitors eight output voltages, one input voltage,
and die temperature. In addition, odd numbered chan-
nels can be configured to measure the voltage across a
current sense resistor. A programmable watchdog timer
monitors microprocessor activity for a stalled condition and
resets the microprocessor if necessary. A single wire bus
synchronizes power supplies across multiple LTC power
system management devices. Configuration EEPROM sup-
ports autonomous operation without additional software.
L,
LT, LTC, LTM, PolyPhase, Linear Technology and the Linear logo are registered trademarks and
LTpowerPlay ia a trademark of Linear Technology Corporation. All other trademarks are the property
of their respective owners. Protected by U.S. Patents including 7382303, 7420359 and 7940091.
n
n
n
n
n
n
n
n
n
Sequence, Trim, Margin and Supervise Eight Power Supplies
Manage Faults, Monitor Telemetry and Create Fault Logs
PMBus Compliant Command Set
Supported by LTpowerPlay™ GUI
Margin or Trim Supplies to 0.25% Accuracy
Fast OV/UV Supervisors per Channel
Coordinate Sequencing and Fault Management
Across Multiple Chips
Automatic Fault Logging to Internal EEPROM
Operate Autonomously without Additional Software
Internal Temperature and Input Voltage Supervisors
Accurate Monitoring of Eight Output Voltages, Input
Voltage and Internal Die Temperature
I
2
C/SMBus Serial Interface
Can Be Powered from 3.3V, or 4.5V to 15V
Programmable Watchdog Timer
100% Compatible with the LTC2978
Available in 64-pin 9mm
×
9mm QFN Package
APPLICATIONS
n
n
n
n
n
Computers and Network Servers
Industrial Test and Measurement
High Reliability Systems
Medical Imaging
Video
TYPICAL APPLICATION
8-Channel PMBus Power System Manager
4.5V < V
IBUS
< 15V**
V
PWR
3.3V**
TO INTERMEDIATE
BUS CONVERTER ENABLE
PMBus
INTERFACE
V
DD33
V
IN_EN
SDA
SCL
ALERTB
CONTROL0
WRITE-PROTECT
TO/FROM OTHER
LTC2978s
WP
FAULTB00
SHARE_CLK
GND
2978a TA01a
Typical ADC Total Unadjusted
Error vs Temperature
V
IN
0.035
0.030
0.025
ERROR (%)
0.020
0.015
0.010
0.005
0
–50 –35 –20 –5 10 25 40 55 70 85 100
TEMPERATURE (°C)
2978a TA01b
ADC V
IN
= 1.8V
V
IN_SNS
V
DACP0
V
SENSEP0
LTC2978A*
V
DACM0
V
SENSEM0
V
OUT_EN0
PWRGD
WDI/RESETB
ASEL0
ASEL1
TO µP RESETB INPUT
WATCHDOG
TIMER INTERRUPT
LOAD
R10
R30
R20
V
OUT
DIGITALLY
MANAGED
POWER
SUPPLY
V
FB
SGND
RUN/SS
GND
*SOME DETAILS OMITTED FOR CLARITY
ONLY ONE OF EIGHT CHANNELS SHOWN
**LTC2978A MAY BE POWERED FROM EITHER AN
EXTERNAL 3.3V SUPPLY OR THE INTERMEDIATE BUS
2978afa
For more information
www.linear.com/LTC2978A
1
The most classic 51 tutorial
For a different teaching method, you can try reading and understanding:http://www.isjtag.com/list.asp?id=30[[i]This post was last edited by paulhyde on 2012-4-28 13:35[/i]]...
paulhyde 51mcu
MSP430F5438A serial port
[i=s]This post was last edited by Hot Ximixiu on 2020-9-12 19:56[/i]4,0,0; // 5UCA0CTL1 |= UCSWRST; // **Put state machine in reset**6 UCA0CTL1 |= UCSSEL_2; // CLK = SMCLK7 UCA0BR0 = 26; // 24MHz/5760...
火辣西米秀 Microcontroller MCU
Airlabi supports 2018 STM32 seminar
[align=center][/align] [align=center][align=left]On September 12, at the popular STMicroelectronics conference held in Beijing, engineers from Airlabi gave a wonderful presentation to engineers at the...
alan000345 MCU
USB interface chip CY7C68013 (3)
[align=left][color=rgb(51, 51, 51)][font=Arial, Helvetica, sans-serif, lip脦脤褤][size=12px]Files included in the firmware[/size][/font] [/color][/align][align=left][color=rgb(51, 51, 51)][font=Arial, He...
chenzhufly FPGA/CPLD
If the network card is set with a static IP, the remote tool sometimes cannot connect. Has anyone encountered this strange problem?
The USB synchronization connection can be connected successfully every time, but the remote tools, such as the registry tool and the Zoom-IN tool, can sometimes connect and sometimes not. It is found ...
xinling150 Embedded System
Signal Processing of Linear Frequency Modulated Stepped Synthetic Aperture Radar System
Abstract: To improve the range resolution, the bandwidth of the transmitted signal is usually increased, which leads to a high sampling rate and A/D conversion rate of the system, a sharp increase in ...
JasonYoo DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1203  681  2300  2209  608  25  14  47  45  13 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号