Stable and highly reliable transmission parameters
Waterblocking technology
Allows efficient and craft-friendly cable preparation in
outdoor or indoor/outdoor applications
Extra tough double jackets
Ideal for harsh environments
Listed OFN-LS and CSA FT4-ST1, IEC 60332-3, IEC
61034 and IEC 60754-2
Meets burn test criteria
Listed MSHA 30 CFR Pt. 7-K
Mining Safety and Health Administration approved
Corning Cable Systems Dielectric, Low-Temperature,
Tray-Rated, Mining and Petrochemical Fiber Optic
Cables are designed for indoor and outdoor use in mining
and petrochemical backbones (aerial and duct) and hori-
zontal intrabuilding and tunnel backbones where limited-
smoke and zero-halogen requirements exist.
Available in 12 different jacket colors that enables easy
visual identification and segregation of cables while still
providing all the required environmental protection of an
indoor/outdoor cable jacket.
The SZ-stranded, loose tube design isolates fibers from
installation and environmental rigors and allows for easy
midspan access. The design also provides high-fiber
density within a given cable diameter, allowing flexibility
to suit many system designs.
The specially formulated black, UV-resistant, flame-
retardant LSZH inner and outer jacket complies with
IEEE-383 flame test. These extra-tough double jackets
resist hazards found in mines and petrochemical com-
plexes, making this cable ideal for any harsh environment
requiring a more robust cable and suitable for direct buri-
al applications. All-dielectric construction provides tensile
strength and eliminates grounding concerns.
Standards
Approval and Listings
National Electrical Code
®
(NEC
®
) OFN-LS, CSA OFN
FT4-ST1, IEEE 383 Flame
Test, IEC 60332-3, IEC
60754-2, IEC 61034
Outdoor aerial and duct;
indoor general purpose
horizontal according to CSA
C22.2
ANSI/ICEA S-104-696
Common Installations
Design and Test Criteria
Dielectric Strength
Members
Water-Swellable
Tape
Water-Swellable
Tape
Dielectric Central
Element
Flame-Retardant
Tape
Fiber
Ripcord
Buffer
Tube
Filling Element
Water-Swellable
Tape
FRNC / LSZH
Inner Jacket
Mining and Petrochemical Cables, 12-Fibers
Mining and Petrochemical Cables, 12-Fibers
FRNC / LSZH
Outer Jacket
Family Spec Sheet 0020_NAFTA_AEN
Page 1 | Revision date 2012-10-19
Mining and Petrochemical Fiber Optic
Cables
Dielectric Strength
Members
Water-Swellable
Tape
Water-Swellable
Tape
Dielectric Central
Element
Flame-Retardant
Tape
Fiber
Ripcord
Buffer
Tube
Filling Element
Water-Swellable
Tape
FRNC / LSZH
Inner Jacket
FRNC / LSZH
Outer Jacket
Mining and Petrochemical Cables, 60-Fibers
False
Mining and Petrochemical Cables, 60-Fibers
Specifications
Temperature Range
Storage
Installation
Operation
-50 °C to 75 °C (-58 °F to 167 °F)
-30 °C to 60 °C (-22 °F to 140 °F)
-50 °C to 75 °C (-58 °F to 167 °F)
* Corning Cable Systems recommends storing indoor/outdoor cable in a proper temperature environment prior to installation to allow the cable temperature to
meet installation temperature range specifications for best installation results.
Mechanical Characteristics Cable
Max. Tensile Strengths, Short-Term
Max. Tensile Strengths, Long-Term
Fiber
Count
12 - 72
96
144
Product Type
Fibers per Number
Tube
of Tube
Positions
12
12
12
6
8
12
4500 N (1000 lbf)
1500 N (333 lbf)
Nominal Outer Min. Bend
Diameter
Radius
Installation
17.6 mm
(0.69 in)
20.4 mm
(0.8 in)
24 mm
(0.94 in)
264 mm
(10.4 in)
306 mm
(12 in)
360 mm
(14.2 in)
Min. Bend
Radius
Operation
176 mm
(6.9 in)
204 mm
(8 in)
240 mm
(9.4 in)
Weight
Dielectric
Dielectric
Dielectric
299 kg/km
(201 lb/1000 ft)
400 kg/km
(269 lb/1000 ft)
529 kg/km
(356 lb/1000 ft)
Family Spec Sheet 0020_NAFTA_AEN
Page 2 | Revision date 2012-10-19
Mining and Petrochemical Fiber Optic
Cables
Fiber
Count
192 - 216
288
Product Type
Fibers per Number
Tube
of Tube
Positions
12
12
18
24
Nominal Outer Min. Bend
Diameter
Radius
Installation
23.3 mm
(0.92 in)
26.3 mm
(1.04 in)
350 mm
(13.8 in)
395 mm
(15.5 in)
Min. Bend
Radius
Operation
233 mm
(9.2 in)
263 mm
(10.4 in)
Weight
Dielectric
Dielectric
472 kg/km
(317 lb/1000 ft)
602 kg/km
(405 lb/1000 ft)
Chemical Resistance
Chemical
ASTM #2 Oil
De-Icing Fluid
Diesel Fuel, MIL-F 16884
Hydraulic Fuel, MIL-H 5606
Hydraulic Fuel, MIL-H 16762
Lubricating Oil, MIL-L23699
Vegetation Killer
Exposure Time
4h
24 h
24 h
24 h
24 h
24 h
168 h
Exposure Temperature
158 °F
122 °F
95 °F
120 °F
120 °F
120 °F
122 °F
Chemical Characteristics
RoHS
Free of hazardous substances according to RoHS 2002/95/
EG
Family Spec Sheet 0020_NAFTA_AEN
Page 3 | Revision date 2012-10-19
Mining and Petrochemical Fiber Optic
Cables
Transmission Performance
Fiber Type
Fiber Core Diameter (µm)
Fiber Category
Fiber Code
Performance Option Code
Wavelengths (nm)
Maximum Attenuation (dB/km)
Serial 1 Gigabit Ethernet (m)
Serial 10 Gigabit Ethernet (m)
Min. Overfilled Launch (OFL)
Bandwidth (MHz*km)
Minimum Effective Modal
Bandwidth (EMB) (MHz*km)
Notes:
Multimode
62.5
OM1
K
30
850 / 1300
3.4 / 1.0
300 / 550
33 / -
200 / 500
220 / -
Multimode
50
OM2
T
31
850 / 1300
3.0 / 1.0
750 / 600
150 / -
700 / 500
950 / -
Multimode
50
OM3
T
80
850 / 1300
3.0 / 1.0
1000 / 600
300 / -
1500 / 500
2000 / -
Multimode
50
OM4
T
90
850 / 1300
3.0 / 1.0
1100 / 600
550 / -
3500 / 500
4700 / -
Multimode
50
OM4
Extended
Distance
T
91
850 / 1300
3.0 / 1.0
1100 / 600
600 / -
3500 / 500
5350 / -
Single-mode
8.2
OS2
E
01
1310 / 1383
/ 1550
0.4 / 0.4 /
0.3
5000 / - / -
10000 / - /
40000
1)
Improved attenuation and bandwidth options available.
2)
Bend-insensitive single-mode fibers available on request.
3)
Contact a Corning Cable Systems Customer Care Representative for additional information.
4)
50 μm multimode fiber macrobend loss ≤ 0.2 dB at 850 nm for two turns around 7.5 mm radius mandrel.
Family Spec Sheet 0020_NAFTA_AEN
Page 4 | Revision date 2012-10-19
Mining and Petrochemical Fiber Optic
Cables
Ordering Information |
Contact Customer Care at 1-800-743-2671 for other options.
This cable is available in 12 different jacket colors: blue, orange, green, brown, slate, white, red, black, yellow, violet, rose and aqua. Black is the standard jacket
color using the part number configurator above. Contact Customer Care at 1-800-743-2675 to order other color options.
Corning Cable Systems LLC • PO Box 489 • Hickory, NC 28603-0489 USA
Discussion: Should djyos be open source? Open source has two meanings. One is that the source code is open and the author owns the copyright. The other is that the source code is open and the copyrigh...
What chips are Texas Instruments' 71J01 and 66J01? Is it a code name or a full name? The Texas Instruments service lady said there is no such product. Where is the technical documentation?...
The diesel engine is shut down or running unstably: The diesel engine is difficult to start or runs unstably. The fuel is contaminated or unsuitable. Drain the fuel and add appropriate fuel. There is ...
Currently, colleagues are asked to use the IDE without connecting to the internet, but this is very troublesome because it is very painful not being able to search for information online while writing...
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guang...[Details]
The data collector of the automatic weather station is generally designed based on a single-chip microcomputer or a PC/104 bus controller. It has the characteristics of good compatibility with PC, low...[Details]
introduction
The emergence of high-performance, low-power embedded CPUs and high-reliability network operating systems has made it possible to implement applications with large amounts of comp...[Details]
1 Introduction
PROFIBUS is an international, open, and manufacturer-independent fieldbus standard. It is widely used in manufacturing automation, process industry automation, and automatio...[Details]
1 Introduction
Water resources are the basic conditions for human survival and the lifeline of economic development. The reality shows that due to the global shortage of water resources and th...[Details]
The TPS92210 is a single-stage LED lighting pulse width modulation (PWM) controller. The TRIAC dimmable solution not only regulates the LED current, but also achieves a power factor close to 1. The...[Details]
0 Introduction
Under normal circumstances, the three-phase power in the power system is symmetrical, and they meet certain amplitude and phase conditions; but when the load changes, the syst...[Details]
The above is to use MB1404 as a stereo composite signal transmitter. You can use the internal high-frequency amplifier and oscillator or not! According to my experience, I still recommend beginners...[Details]
Cars equipped with xenon headlights are already common on the road. Whether they are standard equipment on high-end cars or embellishments on modified cars, xenon lamps are gradually becoming a sym...[Details]
Car lights, whether headlights, fog lights or tail lights, play an important role in driving safety. However, the material of the car lights determines that the probability of damage in a collision...[Details]
In the TV monitoring system, in order to complete the collection of information from various information points (video, audio, alarm signal) and the control of various front-end devices (PTZ, lens,...[Details]
Stepper motors, also called steppers, use the principles of electromagnetism to convert electrical energy into mechanical energy and have been used since the 1920s. With the increasing popularity o...[Details]
With the explosive growth of electronic functions in cars, will more and more luxurious cars endanger the safety of passengers? This is the origin of the problem of over-electrification of cars. What ...[Details]
1 Causes of problems with electric vehicle batteries
1.1 Caused by the battery itself
Why do we say that? In the previous issue, we learned about the working princi...[Details]
Lithium iron phosphate batteries are used as lithium-ion secondary batteries. Their main application is now in power batteries, which have great advantages over NI-H and Ni-Cd batteries.
Lithi...[Details]