Part Number

Search

W260A4N004P1

Description
Power/Signal Relay, DPDT, Momentary, 0.038A (Coil), 26.5VDC (Coil), 1007mW (Coil), 2A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Socket Mount,
CategoryMechanical and electronic products    relay   
File Size1MB,11 Pages
ManufacturerEsterline Technologies Corporation
Download Datasheet Parametric View All

W260A4N004P1 Overview

Power/Signal Relay, DPDT, Momentary, 0.038A (Coil), 26.5VDC (Coil), 1007mW (Coil), 2A (Contact), 28VDC (Contact), DC Input, AC/DC Output, Socket Mount,

W260A4N004P1 Parametric

Parameter NameAttribute value
Objectid4002423247
Reach Compliance Codeunknown
ECCN codeEAR99
body width10.4 mm
body height12.5 mm
Body length or diameter20.6 mm
Maximum coil current (DC)0.038 A
Coil operating voltage (DC)18 V
Coil power1007 mW
Coil release voltage (DC)1 V
Coil resistance700 Ω
Maximum coil voltage (DC)26.5 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load.3A@115VAC
Maximum contact current (AC)0.3 A
Maximum contact current (DC)2 A
Contact (DC) maximum rated R load2A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
JESD-609 codee4
Installation featuresSOCKET MOUNT
operating hours6 ms
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
physical size20.6mm x 10.4mm x 12.5mm
GuidelineMIL-PRF-39016/6
Relay actionMOMENTARY
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
release time6 ms
sealCORROSION PROOF; HERMETICALLY SEALED
surface mountNO
Terminal surfaceGOLD
Termination typeSNAP-ON
W260
ENGINEERING DATA SHEET
RELAY - NONLATCH
2 PDT, 2 AMP
Non polarized, non latching hermetically sealed relay
2 PDT
Contact arrangement
Coil supply
Qualified to
Direct current
MIL-R-39016/6
PRINCIPLE TECHNICAL CHARACTERISTICS
Contacts rated at
Weight
Dimensions of case
without mounting
brackets
APPLICATION NOTES:
001
007
APPLICABLE SOCKETS:
HRCW
SO9005
SF250-R4
2 Amp / 28Vdc
10 grams max
20.6mm x 10.4mm x 10.4mm max
Hermetically sealed corrosion protected metal can.
CONTACT ELECTRICAL CHARACTERISTICS
Minimum
operating cycles
100,000 cycles
100,000 cycles
100,000 cycles
1,000,000
cycles
100 cycles
Contact rating per
pole and load type
resistive load
inductive load (0.2H)
---Type 1
---Type 2
lamp load
low level (10mA/50mV max)
resistive overload
Load Current in Amps
@28Vdc
2
0.75
0.5
0.16
-
4
@115Vac/60-400Hz
0.3
-
-
-
-
-
Featuring
LEACH
©
power and control solutions
www.esterline.com
AMERICAS
6900 Orangethorpe Ave.
P.O. Box 5032
Buena Park, CA 90622
.
.
Tel: (01) 714-736-7599
Fax: (01) 714-670-1145
EUROPE
2 Rue Goethe
57430 Sarralbe
France
.
.
Tel: (33) 3 87 97 31 01
Fax: (33) 3 87 97 96 86
ASIA
Units 602-603 6/F Lakeside 1
No.8 Science Park West Avenue
Phase Two, Hong Kong Science Park
Pak Shek Kok, Tai Po, N.T.
Hong Kong
Tel: (852) 2 191 3830
Fax: (852) 2 389 5803
Data sheets are for initial product selection and comparison. Contact Esterline Power Systems prior to choosing a component.
Date of issue:
9/10
- 37 -
Page 1 of 4
Would you consider domestic DDR4 memory?
I happened to see a domestic DDR4 memory on JD.com. After reading the introduction, I thought it was pretty good. What attracted me most was the lifetime warranty and replacement instead of repair. To...
eric_wang Talking
How to use PFGA simulation to solve these two problems
If anyone has done this, please take a look...
821081701 FPGA/CPLD
Analysis of the advantages and disadvantages of UWB high-precision positioning technology
UWB Positioning AlgorithmAt present, wireless positioning technology refers to positioning algorithms. The most commonly used measurement methods and calculation methods used to determine the location...
兰博 RF/Wirelessly
GD32E231 DIY Contest (4) - How to get long and short keys?
There is only one user button "Wakeup" on the development board, but my project requires at least two states of user input. The simplest method is to identify the user's long press or short press. Thi...
hujj GD32 MCU
An article on anti-static design of electronic systems, share it!
Share an article, a design checklist for ESD protection and EMC-related topics in electronic system design, which is helpful for us to refer to when designing electronic systems. It’s great!...
wu_zhjun Integrated technical exchanges
Can I get that parallel benchmark running?
[align=left][color=#000]Sometimes, choosing between the various voltage reference topologies is a bit like choosing between coffee and water in the morning. Sure, water is refreshing and has the effec...
maylove Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1452  1418  1212  1477  1919  30  29  25  39  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号