EEWORLDEEWORLDEEWORLD

Part Number

Search

804-009-07C12-202EF

Description
Circular Connector, 22 Contact(s), Aluminum Alloy, Male, Solder Terminal, Plug,
CategoryThe connector    The connector   
File Size592KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

804-009-07C12-202EF Overview

Circular Connector, 22 Contact(s), Aluminum Alloy, Male, Solder Terminal, Plug,

804-009-07C12-202EF Parametric

Parameter NameAttribute value
Objectid7191189211
Reach Compliance Codecompliant
ECCN codeEAR99
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typePLUG
Connector typeCIRCULAR CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell surfaceANODIZED BLACK
Shell materialALUMINUM ALLOY
Housing size12
Termination typeSOLDER
Total number of contacts22
Series 804 Push-Pull Mighty Mouse
PC Tail or Solder Cup Panel Mount Plug
804-009, 804-021 Ordering Information
Panel Mount Plugs
save space inside the box compared to Series 804 removable
contact receptacles. Factory-installed non-removable contacts. Solder cup or
printed circuit board terminals. Available in front or rear panel and flange mount
versions.
Ingress Protection, Unmated
Specify
804-009
connectors for applications where
open face water immersion is not a requirement. For IP67 ingress protection and
MIL-STD-810 Method 512 immersion requirements, specify
804-021
watertight
connectors certified to meet one atmosphere pressure differential in open face
condition from -40° to +70°C.
"Push-Pull" Quick-Disconnect
Canted spring securely retains the mating plug.
How To Order
Sample Part Number
Series
G
-00
Jam Nut, Front Panel
Mount
Series 804
Shell Style (See Table I)
Shell Material and Finish
Shell Key Positions
(See Table II)
Table I: Shell Style
-07
Jam Nut, Rear Panel
Mount
© 2014 Glenair, Inc.
804-009
804-009
= Panel Mount Plug, Standard Potting
804-021
= Panel Mount Plug
,Resilient Silicone Potting for
Watertight Seal from -40° to +70°C (1 ATM Pressure Differential)
-00
= Front Panel Mount Jam Nut (See Table IV)
-02
= Flange Mount
-07
= Rear Panel Mount Jam Nut (See Table III)
C
= Aluminum / Black Anodize (Non-Conductive); RoHS Compliant
M
= Aluminum / Electroless Nickel; RoHS Compliant
MT
= Aluminum / Nickel-PTFE RoHS Compliant
NF
= Aluminum / Cadmium with Olive Drab Chromate
ZNU
= Aluminum / Zinc-Nickel with Black Chromate
Z1
= Stainless Steel / Passivated; RoHS Compliant
-07
NF
10-26
E
A
Shell Size - Insert Arrangement
See Contact Arrangements Page G-2
P
= Pin, PC Tail
E
= Pin, Solder Cup
Contact Type
S
= Socket, PC Tail
F
= Socket, Solder Cup
Omit
= Single Master Key
A
= Normal
B
= Pos. B
C
= Pos. C
D
= Pos. D
E
= Pos. E
F
= Pos. F
Table II: Alternate Keyway Positions
Pos.
150°
75°
95°
140°
75°
95°
210°
210°
230°
275°
275°
210°
A
B
-02
Flange Mount
C
D
E
F
Dimensions in Inches (millimeters) are subject to change without notice.
Series 80 Mighty Mouse
U.S. CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC.
1211 AIR WAY
GLENDALE, CA 91201-2497
818-247-6000
FAX 818-500-9912
www.glenair.com
G-12
E-Mail: sales@glenair.com
I have been debugging NIOS-II+Ucos-ii+lcd12864 for several days, but I still don't understand it, so I ask everyone to help me, thank you
My system clock is 100M. Sometimes it can be displayed, but sometimes it cannot be displayed, and the display is garbled. The software code is as follows: //Check busy void Check_Busy(void) {CLR_RS;SE...
tpengti FPGA/CPLD
mp430F5529LP Getting Started (2) ---- Long-lost LED
Finally, I started my programming journey. I searched a lot of information on the Internet and took it step by step. I followed the tutorial step by step and used the powerful resource library of 430w...
星星点点sss Microcontroller MCU
Hardware Engineer
Good news, our company recruits hardware engineers, software engineers, FPGA engineers and sales engineers all year round. Tel: 52297030, hr@queentest.com, hr@queentest.com, http://www.queentest.cn/, ...
kckj Recruitment
How to write data in the code area as if it were code in 430?
In the 51 assembly language, you can define a table through DB, and the compiler will store the table in the code area. In the program, you can access the table content through DPTR. In C51, you can u...
kccch Microcontroller MCU
MSP432P401R LaunchPad user guide, design documentation, examples, etc.
MSP-EXP432P401R LaunchPad User GuideMSP-EXP432P401R Hardware Design FilesMSP-EXP432P401R Software Examples...
maylove Microcontroller MCU
A little trick to prevent copycats!
These days I have seen posts by forum members discussing how to prevent customers from being dishonest, and I would like to share some tips with everyone for their comments! 1. Intimidation. Specifica...
bigbat Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 389  1344  573  1989  409  8  28  12  41  9 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号