High-power-density, an industrial temperature range of -40°C to +85°C and extra features like
On-Off-control are just some of the characteristics of this converter, ideal for highly sophisticated
industrial-designs. The RSO series is available with isolation of 2kV or 3kV by choosing option "/H2"
or "/H3" in which case it is also ideal for medical applications which additionally require EN-60601-
1 certification. The standard version offers 2:1 input voltage range, while the “Z” version features 4:1
input voltage range, which includes an input voltage range covering both 5V and 12V supplies.
Selection Guide
Input
Rated Output Output Current Efficiency
Max
Voltage Range
Voltage
typ.
Capacitive
SIP8
(VDC)
(VDC)
(mA)
(%)
Load
(1)
RSO-xx3.3S*
4.5-9**, 9-18
3.3
300
68-72
3300µF
18-36, 36-72
70
RSO-xx05S*
4.5-9**, 9-18
5
200
73-75
1200µF
18-36, 36-72
75-78
RSO-xx09S*
4.5-9**, 9-18
9
111
74-78
680µF
18-36, 36-72
78-81
RSO-xx12S*
4.5-9**, 9-18
12
83
75-80
680µF
18-36, 36-72
80-83
RSO-xx15S*
4.5-9**, 9-18
15
67
75-80
680µF
18-36, 36-72
80-83
RSO-xx3.3D*
4.5-9**, 9-18
±3.3
±150
68-72
±1500µF
18-36, 36-72
70
RSO-xx05D*
4.5-9**, 9-18
±5
±100
73-75
±470µF
18-36, 36-72
75-76
RSO-xx09D*
4.5-9**, 9-18
±9
±56
74-78
±470µF
18-36, 36-72
78
RSO-xx12D*
4.5-9**, 9-18
±12
±42
75-79
±330µF
18-36, 36-72
79-80
RSO-xx15D*
4.5-9**, 9-18
±15
±34
75-79
±330µF
18-36, 36-72
79-80
RSO-xx3.3SZ*
9-36
3.3
300
68-70
3300µF
18-72
70
RSO-xx05SZ*
4.5-18**, 9-36
5
200
73-78
1200µF
18-72
75
RSO-xx09SZ*
4.5-18**, 9-36
9
111
75-81
680µF
18-72
78
RSO-xx12SZ*
4.5-18**, 9-36
12
83
77-83
680µF
18-72
80
RSO-xx15SZ*
4.5-18**, 9-36
15
67
78-83
680µF
18-72
80
RSO-xx3.3DZ*
9-36
±3.3
±150
70-74
±1500µF
18-72
70
RSO-xx05DZ*
4.5-18**, 9-36
±5
±100
73-77
±470µF
18-72
75
RSO-xx09DZ*
4.5-18**, 9-36
±9
±56
74-78
±470µF
18-72
78
RSO-xx12DZ*
4.5-18**, 9-36
±12
±42
75-80
±330µF
18-72
80
RSO-xx15DZ*
4.5-18**, 9-36
±15
±34
75-80
±330µF
18-72
80
No suffix is standard isolation (1kVDC) e.g, RSO-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RSO-0505S/H2, RSO-0505DZ/H3
** derate to 75% if Vin<5V, 12V 4:1 input also requires an external 10µF input capacitor.
www.recom-power.com
REV: 2/2017
Part Number
1 Watt
SIP8 Isolated
Single
&
Dual
Output
RSO
Derating-Graph
(Ambient Temperature)
100
4:1
2:1
Output Power (%)
80
60
40
30
20
0
Safe Operating Area
-40
0
50 75 100
85
Operating Temperature °C
150
2:1 Input
(RS0-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
4:1 Input
(RSO-SZ/DZ)
xx = 4.5-18Vin = 12
xx = 9-36Vin = 24
xx = 18-72Vin = 48
E-123
ECONOLINE
DC/DC-Converter
Input Voltage Range
Output Voltage Accuracy
Line Voltage Regulation
Load Voltage Regulation
(10% to 100% full load)
Minimum Load
Output Ripple and Noise (20MHz limited)
Operating Frequency
Efficiency at Full Load
Quiescent Current
Nominal input Voltage
(Standard, /H2 and /H3)
CTRL Pin drive current /see Notes)
Quiescent Input Current when Converter is OFF
Isolation Voltage
Standard
/H2 Version
/H3 Version
Isolation Capacitance
Isolation Capacitance
Standard
/H2 and /H3
Standard
/H2 and /H3
Standard
/H2 and /H3
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
2:1 Single
2:1 Single
2:1 Dual
2:1 Dual
4:1 Single/Dual
4:1 Single/Dual
RSO-05xxS_D, SZ_DZ
RSO-12xxS_D, SZ_DZ
RSO-24xxS_D, SZ_DZ
RSO-48xxS_D, SZ_DZ
2:1
4:1
2:1
4:1
2:1
4:1
2:1 and 4:1
±2% typ.
±0.2% max.
±0.5% max.
±0.4% max.
±0.5% typ.
10%
(2)
50mVp-p max.
200kHz min. / 500kHz max.
100kHz min. / 800kHz max.
See Selection Guide
40mA typ.
32mA typ.
25mA typ.
15mA typ.
3mA typ, 6mA max.
10mA max.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
5pF min. / 30pF typ. / 60pF max.
200pF max.
30pF max.
>1GΩ min.
Continuous
-40°C to +85°C (see Graph)
-55°C to +125°C
95% RH
4.7g
22 pcs per Tube
Detailed Information see
Application Notes chapter "MTBF"
RSO-S_D(Z)
Series
Specifications
(Core Operating Area)
measured at TA = 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified
RSO-24xxS
Efficiency / Load
100
80
60
40
2412
2409
2405
2415
Efficiency %
20
0
0%
20%
40%
60%
80%
100%
Total Output current (%)
RSO-1205SZ
Efficiency / Load
100
80
60
40
RS0
Isolation Capacitance
Isolation Capacitance
Isolation Capacitance
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
1205SZ
Efficiency %
20
0
Operating Temperature Range (free air convection)
Storage Temperature Range
Relative Humidity
Package Weight
Packing Quantity
MTBF (+25°C)
(+85°C)
Certifications
EN General Safety
EN Medical Safety
UL General Safety
Notes
Note 1:
Note 2:
Report: SPCLVD1605077-10
Report: MDD1205098-3 + RM1205098-3
Report: E224736-A34
0%
20%
40%
60%
80%
100%
Total Output current (%)
}
using MIL-HDBK 217F
using MIL-HDBK 217F
1685 x 10
3
hours
254 x 10 hours
EN60950-1, AM2:2013
3
**Any data referred to in this datasheet are of indicative nature and
based on our practical experience only. For further details, please
refer to our Application Notes.
IEC/EN 60601-1 3rd Edition
UL60950-1, 2nd Edition 2014
Medical Report + ISO14971 Risk Assessment
CSA C22.2 60950-1-07, 2nd Edition 2014
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
The RSO series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
E-124
REV: 2/2017
www.recom-power.com
ECONOLINE
DC/DC-Converter
Typical Application
+Vin
10µF input MLCC
capacitor
required for
RSO-12xxSZ_DZ
only.
-Vin
Vin-
Fuse
Vin+
Vout+
RSO-S_D(Z)
Series
+Vout
RSO
Vout-
-Vout
Package Style and Pinning (mm)
8 PIN SIP Package
9.20
11.10
4.1
Single Output
Dual Output
RECOM
R S O - x x x x S _ D
0.50±0.05
****
0.50±0.05
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
RECOM
RSO-xxxxS
****
1 2 3
5 6 7 8
RECOM
RSO-xxxxD
****
1 2 3
5 6 7 8
Recommended Footprint Details
1.0ø+0.15/0
Pin Connections
Pin #
1
2
3
5
6
Single
–Vin
+Vin
CTRL
NC
+Vout
–Vout
NC*
Dual
–Vin
+Vin
CTRL
NC
+Vout
Com
–Vout
21.80
0.25
Bottom View
2.54
3.20
2.0
2.54
Top View
7
8
CTRL Examples:
Pin 8 (NC*)
This pin is used internally and must have no external connection.
Pin 5 (NC)
Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode.
When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is
ON. There is no allowed low state for this pin.
NC = No Connection
NC* = NC, but no external Connection allowed.
RSO
ON/OFF CONTROL
V+
V
IN
+
ON
OFF
V
IN
-
10K
-Vin
+Vin
+Vout
LEAVE OPEN
CTRL
3
5~12
1N4148
68
CTRL
-Vout
Ω
FET.
V-
Remote ON/OFF
ON: open or high impedance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor
I
= 3V
O = 0.5V or GND
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
Recently, I have used 51 single-chip microcomputer to control Q2406B to send and receive text messages and implemented several functions: Function: Set the transmission rate Setting method: AT+ipr=960...
[url]http://www.ti.com/tool/sensortag-sw[/url] The source code of CC2650 app for IOS and Android platforms is on Gitorious@TI. I need to clone it, but I don’t know how to clone it after a long time. P...
Embedding web pages can realize basic functions such as submission. Using ssi and cgi methods
The problem is as follows:
1. How to read the data on the board to the web page, and display the board's I...
Why does 8086 require boundary alignment, that is, word addresses must be even addresses? What problems will occur if the boundaries are not aligned?...
As a wireless broadband metropolitan area network standard, WiMAX technology has greater advantages than previous 3.5GHz MMDS products in terms of non-line-of-sight transmission and spectrum utiliz...[Details]
Remote keyless entry (RKE) systems have become popular with users, with more than 80% of new cars in North America and more than 70% in Europe equipped with RKE systems. In addition to the obvious ...[Details]
We know that microcontroller development tools generally include real-time online emulators and programmers. Among them, online emulators are very good tools, but they are also more expensive...[Details]
5. Identifiers and keywords of C language
A complete PIC microcontroller C language program usually consists of six parts: include files (i.e. header files 1, variable definitions, variable de...[Details]
1. Background:
The instrument system parameter detection and control of the chemical production workshop of Tangshan Coal Gas Coking Plant are all analog instruments, some of which are eve...[Details]
1. System Structure
This system is a simulation system of indoor air-conditioning temperature/humidity control system. The data acquisition and control center collects temperature/humidity...[Details]
As a simple and practical input device, buttons have been used in various microcontroller application systems and are ubiquitous. However, the buttons used in different practical occasions are also...[Details]
Abstract: In recent years, with the establishment and grid-connected power generation of a large number of solar photovoltaic power stations at home and abroad, photovoltaic grid-connected inverter...[Details]
Against the backdrop of global warming, energy conservation and emission reduction have become a global hotspot and focus, which has also sounded the clarion call for the take-off of the LED lighti...[Details]
1 Development of LED Film and Television Lighting
1.1 The significance of developing film and television lighting
Lighting power consumption accounts for a large proportion of the total p...[Details]
The emergence and development of street lamps are inseparable from the prosperity and progress of cities, which makes street lamps useful. Conversely, street lamps also make the night of the city n...[Details]
1 Load Regulation
Changes in power supply load will cause changes in power supply output. When the load increases, the output decreases, and vice versa, when the load decreases, the output inc...[Details]
Mobile phones, MP3s, tablet computers, laptops, digital cameras, handheld game consoles, navigation devices, etc., all these mobile devices are powered by mobile batteries, and the battery life is ...[Details]
Features
POE technology can ensure the safety of existing structured cabling while ensuring the normal operation of the existing network and minimizing costs. The IEEE 802.3af standard is ...[Details]