High power-density, an industrial temperature range of -40°C to +85°C and extra features
like Remote-On-Off- control are just some of the characteristics of this converter, ideal for
highly sophisticated industrial designs. The RS series is available with isolation of 2kV or 3kV
by choosing option "/H2" or "/H3" in which case it is also ideal for medical applications which
additionally require EN-60601-1 certification.
Selection Guide
5V, 12V, 24V and 48V Input Types
Part Number
Input
Rated Output Output Current
Voltage Range
Voltage
at Full Load
SIP8
(VDC)
(VDC)
(mA)
RS-xx3.3S (H2/H3)
4.5-9, 9-18
3.3
500
18-36, 36-72
RS-xx05S (H2/H3)
4.5-9, 9-18
5
400
18-36, 36-72
RS-xx09S (H2/H3)
4.5-9, 9-18
9
222
18-36, 36-72
RS-xx12S (H2/H3)
4.5-9, 9-18
12
166
18-36, 36-72
RS-xx15S (H2/H3)
4.5-9, 9-18
15
134
18-36, 36-72
RS-xx3.3D (H2/H3)
4.5-9, 9-18
±3.3
±250
18-36, 36-72
RS-xx05D (H2/H3)
4.5-9, 9-18
±5
±200
18-36, 36-72
RS-xx09D (H2/H3)
4.5-9, 9-18
±9
±111
18-36, 36-72
RS-xx12D (H2/H3)
4.5-9, 9-18
±12
±83
18-36, 36-72
RS-xx15D (H2/H3)
4.5-9, 9-18
±15
±67
18-36, 36-72
RS-xx3.3SZ (H2/H3)
9-36
3.3
500
18-72
RS-xx05SZ (H2/H3)
9-36
5
400
18-72
RS-xx09SZ (H2/H3)
9-36
9
222
18-72
RS-xx12SZ (H2/H3)
9-36
12
166
18-72
RS-xx15SZ (H2/H3)
9-36
15
134
18-72
RS-xx3.3DZ (H2/H3)
9-36
±3.3
±250
18-72
RS-xx05DZ (H2/H3)
9-36
±5
±200
18-72
RS-xx09DZ (H2/H3)
9-36
±9
±111
18-72
RS-xx12DZ (H2/H3)
9-36
±12
±83
18-72
RS-xx15DZ (H2/H3)
9-36
±15
±67
18-72
Efficiency
typ.
(%)
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
75
75
80
80
80
80
83
83
84
84
73
73
77
77
80
80
81
81
83
83
Max
Capacitive
Load
4700µF
1000µF
1000µF
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
4700µF
1000µF
1000µF
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
100
2 Watt
SIP8 Isolated
Single
&
Dual
Output
2011/65/EU
6/6
RoHS
E-224736
UL-60950-1 Certified
EN-60950-1 Certified
EN-60601-1 Certified*
(*/H suffix)
RS
Derating-Graph
(Ambient Temperature)
RS-S(Z)_D(Z)
Output Power (%)
80
60
40
30
20
0
4:1
2:1
Safe Operating Area
-40
0
50 75 100
85
Operating Temperature °C
150
No suffix is standard isolation (1kVDC) e.g, RS-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS-0505S/H2, RS-0505DZ/H3
E-126
REV: 2/2017
2:1 Input
(RS-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
4:1 Input
(RS-SZ/DZ)
xx = 9-36Vin = 24
xx = 18-72Vin = 48
www.recom-power.com
ECONOLINE
DC/DC-Converter
Input Voltage Range
Output Accuracy
Line Voltage Regulation
Load Voltage Regulation
Minimum Load
Output Ripple and Noise (20MHz limited)
Switching Frequency
Efficiency at Full Load
Quiescent Current
Nominal input Voltage
(Standard, /H2 and /H3)
Isolation Voltage
Standard
/H2 Version
/H3 Version
Isolation Capacitance
Standard
/H2 and /H3
Standard
/H2 and /H3
Standard
/H2 and /H3
Full Load
RS-05xxS_D
RS-12xxS_D
RS-24xxS_D, SZ_DZ
RS-48xxS_D, SZ_DZ
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
2:1 Single
2:1 Single
2:1 Dual
2:1 Dual
4:1 Single/Dual
4:1 Single/Dual
20%-100% Load
RS-S_D(Z)
Series
2:1 and 4:1
±2% typ.
±0.5% max.
±0.5% max.
10%
(2)
50mVp-p max.
100kHz min. / 300kHz max.
See Selection Guide
40mA typ.
32mA typ.
25mA typ.
15mA typ.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
5pF min. / 30pF typ. / 60pF max.
200pF max.
30pF max
1GΩ min.
2:1
4:1
Continuous
–40°C to +85°C
–40°C to +75°C
–55°C to +125°C
95% RH
4.7g
22 pcs per Tube
using MIL-HDBK 217F
using MIL-HDBK 217F
Report: SPCLVD1605077-10
Report: MDD1205098-3 + RM1205098-3
Report: E224736-A35
1398 x 10
3
hours
210 x 10
3
hours
EN60950-1, AM2:2013
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
Specifications
(measured at T
A
= 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified)
Isolation Resistance
Short Circuit Protection
Operating Temperature Range
(No Derating)
Storage Temperature Range
Relative Humidity
Package Weight
Packing Quantity
MTBF (+25°C)
(+85°C)
Certifications
EN General Safety
EN Medical Safety
UL General Safety
RS
}
Detailed Information see
Application Notes chapter "MTBF"
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1:
Note 2:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
www.recom-power.com
REV: 2/2017
E-127
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency / Load
100
80
60
40
RS-S_D(Z)
Series
RS-05xx types
2
1.70
1.5
RS-24xx
2412
Output Power (W)
2405
2415
2409
Efficiency %
1
0.5
0
20
0
0%
20%
40%
60%
80%
100%
4.5 5
6
7
8
9
Total Output current (%)
Input Voltage (V)
Package Style and Pinning (mm)
8 PIN SIP Package
9.20
Single Output
Dual Output
11.10
4.1
RECOM
RS-xxxxS_D
****
0.50±0.05
RECOM
RS-xxxxS
****
1 2 3
5 6 7 8
RECOM
RS-xxxxD
****
1 2 3
5 6 7 8
0.50±0.05
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin Connections
Recommended Footprint Details
2.54
1.0ø+0.15/0
Pin #
1
2
3
5
6
7
8
Single
–Vin
+Vin
CTRL
NC
+Vout
–Vout
NC*
Dual
–Vin
+Vin
CTRL
NC
+Vout
Com
–Vout
21.80
0.25
Bottom View
3.20
2.0
2.54
Top View
RS
NC = No Connection
NC* = NC, but no external Connection allowed.
Pin 8 (NC*)
This pin is used internally and must have no external connection.
Pin 5 (NC)
Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is ON.
There is no allowed low state for this pin.
Application Examples
ON/OFF CONTROL
V+
+Vin
V
IN
+
ON
OFF
V
IN
-
LEAVE OPEN
CTRL
+Vout
3
5~12
-Vin
1N4148
68
Ω
CTRL
-Vout
10K
FET.
V-
I
= 3V
O = 0.5V or GND
Remote ON/OFF
ON: open or high impendance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
Urgent recruitment: 1. Technical experts: LTE modem, RF, GNSS direction is all OK 2. Multimedia and Graphic Manager. 3. Linux AE, audio and video direction 4. Test Engineer, Multimedia, Connectivity, ...
This is the category of DC-DC. This circuit is also very useful in normal times. Some battery-powered products often boost the voltage. First open the power design interface, and then enter the parame...
[p=28, 2, left][color=rgb(51, 51, 51)][font=宋体]In circuit design, if we want to control the current, we can't do without the help of [b]transistors[/b]. The full name of the transistor we commonly cal...
Vector network analyzer is a magical measuring instrument, its function is very powerful and worth exploring. Today, Boyu Xunming engineers will briefly introduce the Smith chart in the vector network...
I talked with SOSO this morning, and with the advice of some friends, we can apply for our main chip from TI, so that the cost of our board can be further reduced. It is best to use the school email o...
The problem of dynamic sealing of equipment always exists with the operation of the equipment. Today, we have specially sorted out the various commonly used sealing forms, usage scope and character...[Details]
On August 22, Lantu Motors officially launched its Lanhai Intelligent Hybrid technology via an online livestream. This intelligent hybrid technology, which integrates a full-range 800V high-voltage...[Details]
Based on a survey of more than ten intelligent robot companies, this article sorts out and analyzes the current development status of the intelligent industry and the challenges and differences it ...[Details]
Common Mode Semiconductor has officially released its latest generation of power management ICs—the GM6506 series. This fully integrated high-frequency synchronous rectification step-down p...[Details]
With the rapid development of electric vehicles in my country, people are beginning to pay attention to the issue of radiation from electric vehicles. We all know that mobile phones emit radiation,...[Details]
On August 22, the Wall Street Journal reported on the 21st local time that the new US government does not plan to acquire equity in semiconductor wafer foundry giant TSMC and Micron, one of the thr...[Details]
Tools/Materials
Yitong Chuanglian MODBUS to PROFIBUS Gateway YT-PB-03
Siemens s7-300
This article describes how to configure the YT-PB-03 MODBUS to PROFIBUS gat...[Details]
The range of an electric vehicle is crucial to the driving experience, and range anxiety is a common headache when driving an electric vehicle. Although the latest electric vehicles can achieve a r...[Details]
Summer is the peak season for buying and using air conditioners. Do you pay attention to the energy efficiency of your air conditioner? Did you buy a DC inverter air conditioner? Do you know the re...[Details]
introduction
In today's busy society, people experience chronic high stress, which in turn poses a significant threat to our health. Therefore, effectively relieving stress has become a pr...[Details]
As a core component of electric vehicles, power batteries, like batteries for other electronic products, inevitably experience degradation after a certain period of use due to their characteristics...[Details]
In industrial production, many different controllers are often used, such as those for pressure, flow, electrical parameters, temperature, and sound. However, due to the limitations of the on-site ...[Details]
Recently, UBTECH announced its patent for "robot self-battery replacement structure, device and method".
The Qichacha patent abstract shows that the robot's self-battery replacement stru...[Details]
Vision is the most sensitive and direct way for humans to perceive things. It allows us to acquire a wealth of information about our surroundings without physical contact. However, due to the compl...[Details]
PLC is the foundation of modern industry. Although it is a product of the Second Industrial Revolution, it has experienced nearly a century of ups and downs. Not only has it not disappeared, but it...[Details]