High power-density, an industrial temperature range of -40°C to +85°C and extra features
like Remote-On-Off- control are just some of the characteristics of this converter, ideal for
highly sophisticated industrial designs. The RS series is available with isolation of 2kV or 3kV
by choosing option "/H2" or "/H3" in which case it is also ideal for medical applications which
additionally require EN-60601-1 certification.
Selection Guide
5V, 12V, 24V and 48V Input Types
Part Number
Input
Rated Output Output Current
Voltage Range
Voltage
at Full Load
SIP8
(VDC)
(VDC)
(mA)
RS-xx3.3S (H2/H3)
4.5-9, 9-18
3.3
500
18-36, 36-72
RS-xx05S (H2/H3)
4.5-9, 9-18
5
400
18-36, 36-72
RS-xx09S (H2/H3)
4.5-9, 9-18
9
222
18-36, 36-72
RS-xx12S (H2/H3)
4.5-9, 9-18
12
166
18-36, 36-72
RS-xx15S (H2/H3)
4.5-9, 9-18
15
134
18-36, 36-72
RS-xx3.3D (H2/H3)
4.5-9, 9-18
±3.3
±250
18-36, 36-72
RS-xx05D (H2/H3)
4.5-9, 9-18
±5
±200
18-36, 36-72
RS-xx09D (H2/H3)
4.5-9, 9-18
±9
±111
18-36, 36-72
RS-xx12D (H2/H3)
4.5-9, 9-18
±12
±83
18-36, 36-72
RS-xx15D (H2/H3)
4.5-9, 9-18
±15
±67
18-36, 36-72
RS-xx3.3SZ (H2/H3)
9-36
3.3
500
18-72
RS-xx05SZ (H2/H3)
9-36
5
400
18-72
RS-xx09SZ (H2/H3)
9-36
9
222
18-72
RS-xx12SZ (H2/H3)
9-36
12
166
18-72
RS-xx15SZ (H2/H3)
9-36
15
134
18-72
RS-xx3.3DZ (H2/H3)
9-36
±3.3
±250
18-72
RS-xx05DZ (H2/H3)
9-36
±5
±200
18-72
RS-xx09DZ (H2/H3)
9-36
±9
±111
18-72
RS-xx12DZ (H2/H3)
9-36
±12
±83
18-72
RS-xx15DZ (H2/H3)
9-36
±15
±67
18-72
Efficiency
typ.
(%)
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
68-69
70-73
73-75
78
74-78
81
75-80
83
75-80
83
75
75
80
80
80
80
83
83
84
84
73
73
77
77
80
80
81
81
83
83
Max
Capacitive
Load
4700µF
1000µF
1000µF
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
4700µF
1000µF
1000µF
1000µF
1000µF
±2200µF
±680µF
±680µF
±680µF
±680µF
100
2 Watt
SIP8 Isolated
Single
&
Dual
Output
2011/65/EU
6/6
RoHS
E-224736
UL-60950-1 Certified
EN-60950-1 Certified
EN-60601-1 Certified*
(*/H suffix)
RS
Derating-Graph
(Ambient Temperature)
RS-S(Z)_D(Z)
Output Power (%)
80
60
40
30
20
0
4:1
2:1
Safe Operating Area
-40
0
50 75 100
85
Operating Temperature °C
150
No suffix is standard isolation (1kVDC) e.g, RS-0505S
*add suffix /H2 or /H3 for 2kVDC or 3kVDC isolation, e.g, RS-0505S/H2, RS-0505DZ/H3
E-126
REV: 2/2017
2:1 Input
(RS-S/D)
xx = 4.5-9Vin = 05
xx = 9-18Vin = 12
xx = 18-36Vin = 24
xx = 36-72Vin = 48
4:1 Input
(RS-SZ/DZ)
xx = 9-36Vin = 24
xx = 18-72Vin = 48
www.recom-power.com
ECONOLINE
DC/DC-Converter
Input Voltage Range
Output Accuracy
Line Voltage Regulation
Load Voltage Regulation
Minimum Load
Output Ripple and Noise (20MHz limited)
Switching Frequency
Efficiency at Full Load
Quiescent Current
Nominal input Voltage
(Standard, /H2 and /H3)
Isolation Voltage
Standard
/H2 Version
/H3 Version
Isolation Capacitance
Standard
/H2 and /H3
Standard
/H2 and /H3
Standard
/H2 and /H3
Full Load
RS-05xxS_D
RS-12xxS_D
RS-24xxS_D, SZ_DZ
RS-48xxS_D, SZ_DZ
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
2:1 Single
2:1 Single
2:1 Dual
2:1 Dual
4:1 Single/Dual
4:1 Single/Dual
20%-100% Load
RS-S_D(Z)
Series
2:1 and 4:1
±2% typ.
±0.5% max.
±0.5% max.
10%
(2)
50mVp-p max.
100kHz min. / 300kHz max.
See Selection Guide
40mA typ.
32mA typ.
25mA typ.
15mA typ.
1000VDC
500VAC / 60Hz
2000VDC
1000VAC / 60Hz
3000VDC
1500VAC / 60Hz
10pF min. / 40pF typ. / 60pF max.
5pF min. / 30pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
5pF min. / 30pF typ. / 60pF max.
200pF max.
30pF max
1GΩ min.
2:1
4:1
Continuous
–40°C to +85°C
–40°C to +75°C
–55°C to +125°C
95% RH
4.7g
22 pcs per Tube
using MIL-HDBK 217F
using MIL-HDBK 217F
Report: SPCLVD1605077-10
Report: MDD1205098-3 + RM1205098-3
Report: E224736-A35
1398 x 10
3
hours
210 x 10
3
hours
EN60950-1, AM2:2013
IEC/EN 60601-1 3rd Edition
Medical Report + ISO14971 Risk Assessment
UL60950-1, 2nd Edition 2014
CSA C22.2 60950-1-07, 2nd Edition 2014
Specifications
(measured at T
A
= 25°C, nominal input voltage, full load and after warm-up time unless otherwise specified)
Isolation Resistance
Short Circuit Protection
Operating Temperature Range
(No Derating)
Storage Temperature Range
Relative Humidity
Package Weight
Packing Quantity
MTBF (+25°C)
(+85°C)
Certifications
EN General Safety
EN Medical Safety
UL General Safety
RS
}
Detailed Information see
Application Notes chapter "MTBF"
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
Notes
Note 1:
Note 2:
Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second without damage to the converter
The RS series requires a minimum of 10% load on the output to maintain specified regulation. Operating under no-load conditions
will not damage these devices; however, they may not meet all listed specifications.
www.recom-power.com
REV: 2/2017
E-127
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency / Load
100
80
60
40
RS-S_D(Z)
Series
RS-05xx types
2
1.70
1.5
RS-24xx
2412
Output Power (W)
2405
2415
2409
Efficiency %
1
0.5
0
20
0
0%
20%
40%
60%
80%
100%
4.5 5
6
7
8
9
Total Output current (%)
Input Voltage (V)
Package Style and Pinning (mm)
8 PIN SIP Package
9.20
Single Output
Dual Output
11.10
4.1
RECOM
RS-xxxxS_D
****
0.50±0.05
RECOM
RS-xxxxS
****
1 2 3
5 6 7 8
RECOM
RS-xxxxD
****
1 2 3
5 6 7 8
0.50±0.05
XX.X ± 0.5 mm
XX.XX ± 0.25 mm
Pin Connections
Recommended Footprint Details
2.54
1.0ø+0.15/0
Pin #
1
2
3
5
6
7
8
Single
–Vin
+Vin
CTRL
NC
+Vout
–Vout
NC*
Dual
–Vin
+Vin
CTRL
NC
+Vout
Com
–Vout
21.80
0.25
Bottom View
3.20
2.0
2.54
Top View
RS
NC = No Connection
NC* = NC, but no external Connection allowed.
Pin 8 (NC*)
This pin is used internally and must have no external connection.
Pin 5 (NC)
Not connected internally.
Pin 3 (CTRL)
This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is ON.
There is no allowed low state for this pin.
Application Examples
ON/OFF CONTROL
V+
+Vin
V
IN
+
ON
OFF
V
IN
-
LEAVE OPEN
CTRL
+Vout
3
5~12
-Vin
1N4148
68
Ω
CTRL
-Vout
10K
FET.
V-
I
= 3V
O = 0.5V or GND
Remote ON/OFF
ON: open or high impendance
OFF: external 5~12 Vdc and 1N4148+ 68Ω resistor
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
DPM for embedded Linux is an evolving technology. The core technology is improving thanks to contributions from developers in the global open source community, but practical applications still have to...
1) Don't rush. As the saying goes: more haste, less speed. After all, hardware programming is very different from software programming. Otherwise, once you make a mistake, you won't know where to star...
I changed the registry to change the explorer of Launch50 to myapp. To be safe, I also added two buttons, regedit and suspend saving, thinking that even if it doesn’t work, I can still modify the regi...
[i=s]This post was last edited by Jacktang on 2018-11-04 15:39[/i] Everything you need to develop and run applications for the TMS570LS1227 microcontroller is included: Board: – TMS570LS12 cardCables ...
Sailing is gaining more and more attention. How to use modern technology to assist training and improve competition results is particularly important. Considering the real-time data collection in t...[Details]
No matter which processor you are learning, the first thing you need to understand is the registers and working mode of the processor.
ARM has 37 registers, including 31 general registers and ...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
As a simple and practical input device, buttons have been used in various microcontroller application systems and are ubiquitous. However, the buttons used in different practical occasions are also...[Details]
12v Lead Acid batteries used in trucks, cars, RVs and uninterruptible power supplies are usually rated at 12V. This circuit monitors the battery, the charge and discharge curves, gives the cu...[Details]
The serial interface real-time clock chip DS1302 launched by Dallas Company in the United States can trickle charge the backup battery of the clock chip. Due to the main features of the chip such a...[Details]
0 Introduction
Ultrasonic waves
are mechanical waves with a frequency of more than 20KHz, and the propagation speed in the air is about 340 m/s (at 20°C). Ultrasonic waves can be gene...[Details]
introduction
Steam turbines are driven by high-temperature and high-pressure steam generated by boilers to run at high speed. They are key power equipment in thermal power plants. The emergenc...[Details]
As the global LED market demand continues to increase, my country's LED industry will face huge opportunities in the future. However, the core LED technology and patents are basically monopolized b...[Details]
introduction
At present, the research on micron and nanotechnology is very active, which has led to the rapid development of microtechnology and micro-mechanical electronic system (MEMS) t...[Details]
At present, with the diversification of portable products and the almost harsh requirements for audio and video parts, the power consumption requirements of the whole machine have been raised to a ...[Details]
The most important components of new energy electric vehicles are power batteries, electric motors and energy conversion control systems. The power battery must achieve high performance such as fas...[Details]
1. Tips for charging UPS for the first time
After purchasing a new UPS, plug the UPS into the 220V mains power grid and charge it for at least 12 hours to ensure that the battery is fully char...[Details]
It should be understood as follows: DC-DC means direct current to direct current (conversion of different DC power values). Anything that meets this definition can be called a DC-DC converter, incl...[Details]
In some motion control systems with simple control or low cost requirements, stepper motors are often used as actuators. The biggest advantage of stepper motors in such applications is that they ca...[Details]