EEWORLDEEWORLDEEWORLD

Part Number

Search

2200JGF6008F3HB

Description
Strain Guage Sensor, Gage, 0Psi Min, 60Psi Max, 0.15%, 0.50-5.50V, Cylindrical
CategoryThe sensor    Sensor/transducer   
File Size507KB,4 Pages
ManufacturerGems Sensors & Controls
Download Datasheet Parametric View All

2200JGF6008F3HB Overview

Strain Guage Sensor, Gage, 0Psi Min, 60Psi Max, 0.15%, 0.50-5.50V, Cylindrical

2200JGF6008F3HB Parametric

Parameter NameAttribute value
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Maximum accuracy(%)0.15%
shellSTAINLESS STEEL
Nominal offset0.50V
Maximum operating temperature50 °C
Minimum operating temperature-20 °C
Output range0.50-5.50V
Output typeANALOG VOLTAGE
Package Shape/FormCYLINDRICAL
port type1/8 NPT
Maximum pressure range60 Psi
Minimum pressure range
Pressure sensing modeGAGE
Sensor/Transducer TypePRESSURE SENSOR,STRAIN GUAGE
Maximum supply voltage35 V
Minimum supply voltage1.5 V
Termination typeMETAL CABLE GLAND
Base Number Matches1
wince database application development issues
I am new to Wince and want to develop applications under Wince. I plan to put all database service programs on the Wince device without synchronizing with the PC. The database is SQL Server ce 2.0 and...
richard.kong Embedded System
Application of common pressure control devices
As the name implies, pressure control devices are the general term for valves that control pressure, sometimes referred to as pressure valves. The following introduces the applications of three common...
unsbizj@sina.cn Industrial Control Electronics
Can anyone recommend some books about uCLinux?
RT...
laker28 Linux and Android
Multi-channel data acquisition program problems
Please help me look at this program, the purpose is to realize multi-channel data acquisition, collect temperature, the sensor is a platinum resistance, the collected temperature is processed and then...
xheshui Embedded System
【AT-START-F425 Review】 4. External interrupts and code analysis
AT-START-F425 provides official routines, which are quite complete. In the external interrupt routine, we can see two routines, namely external interrupt and software triggered interrupt. The specific...
kit7828 Domestic Chip Exchange
Urgent! Battery problem!
I use a 2450 platform. The question I asked before was that when the battery power reaches 100%, the battery icon in the system tray disappears. Now I find that when the power is above the value of BA...
lejiao Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 294  947  2873  1857  241  6  20  58  38  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号