Operating Temperature Range .........................-40°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range .............................-65°C to +150°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow) .......................................+260°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(V
IN
= 14V, C
IN
= 0.1µF, C
OUT
= 10µF, T
A
= T
J
= -40°C to +125°C, unless otherwise noted. Typical values are at T
A
= T
J
= +25°C.)
(Note 1)
PARAMETER
Supply Voltage Range
SYMBOL
V
IN
I
LOAD
= 0A
Supply Current
(MAX6765–MAX6772) (Note 2)
I
LOAD
= 50mA
I
LOAD
= 100mA, V
IN
= 14V
I
LOAD
= 0A, V
IN
= 42V
I
LOAD
= 10mA, V
IN
= 42V
I
LOAD
= 0A
I
LOAD
= 50mA
I
LOAD
= 100mA
I
LOAD
= 0A, V
IN
= 42V
I
LOAD
= 10mA, V
IN
= 42V
I
SHDN
ENABLE , ENABLE1, ENABLE2 = GND
L/M, I
LOAD
= 1mA
L/M, 1mA
≤
I
LOAD
≤
100mA, V
IN
= 11V
T/S, I
LOAD
= 1mA
Output Voltage
V
OUT
T/S, 1mA
≤
I
LOAD
≤
100mA, V
IN
= 9.3V
Z/Y, I
LOAD
= 1mA
Z/Y, 1mA
≤
I
LOAD
≤
100mA, V
IN
= 8.5V
W/V, I
LOAD
= 1mA
W/V, 1mA
≤
I
LOAD
≤
100mA, V
IN
= 7.8V
Adjustable Output Voltage Range
SET Threshold Voltage
(MAX6767–MAX6774)
Dual Mode™ SET Threshold
V
OUT
V
SET
I
LOAD
= 1mA
SET rising
SET falling
4.925
4.850
3.251
3.201
2.463
2.425
1.773
1.746
1.8
1.20
1.233
116
58
mV
CONDITIONS
MIN
4
31
35
37
35
37
38
42
44
42
44
3.3
5
5
3.3
3.3
2.5
2.5
1.8
1.8
TYP
MAX
72
45
50
55
50
55
50
55
60
55
60
7
5.075
5.150
3.350
3.399
2.538
2.575
1.827
1.854
11.0
1.26
V
V
V
µA
µA
UNITS
V
Supply Current
(MAX6773/MAX6773B/
MAX6774/MAX6774B)
(Note 2)
Shutdown Supply Current
µA
Dual Mode is a trademark of Maxim Integrated Products, Inc.
Maxim Integrated
2
MAX6765–MAX6774
Automotive Micropower Linear Regulators
with Supervisor
ELECTRICAL CHARACTERISTICS (continued)
(V
IN
= 14V, C
IN
= 0.1µF, C
OUT
= 10µF, T
A
= T
J
= -40°C to +125°C, unless otherwise noted. Typical values are at T
A
= T
J
= +25°C.)
(Note 1)
PARAMETER
SET Input Current
(MAX6767–MAX6774)
SYMBOL
I
SET
CONDITIONS
V
SET
= 1.5V, V
IN
= 11V
L/M, 5V output option, I
LOAD
= 10mA
Dropout Voltage (Note 3)
ΔV
DO
L/M, 5V output option, I
LOAD
= 50mA
L/M, 5V output option, I
LOAD
= 100mA
T/S, 3.3V output option, I
LOAD
= 100mA
Guaranteed Output Current
(Note 4)
Output Current Limit
Thermal-Shutdown Temperature
Thermal-Shutdown Hysteresis
Line Regulation
Load Regulation
(MAX6767–MAX6774)
Power-Supply Rejection Ratio
Startup Response Time
Output Overvoltage Protection
Threshold
Output Overvoltage Protection
Maximum Sink Current
Input Low Voltage
Input High Voltage
ENABLE, ENABLE1, ENABLE2
Input Pulldown Current
V
IL
HOLD
Input Threshold Voltage
HOLD
Input Pullup Current
RESET
OUTPUT
L
M
T
RESET
Threshold
SET = GND,
RESET
falling
S
Z
Y
W
V
Maxim Integrated
MIN
-100
TYP
MAX
+100
UNITS
nA
60
300
620
866
100
130
630
1200
1600
mA
mV
Output shorted to GND, V
IN
= 14V
150
250
160
20
mA
°C
°C
1
1.5
%
%
dB
µs
1.13 x
V
OUT
V
mA
6.5V
≤
V
IN
≤
72V, I
LOAD
= 1mA
I
OUT
= 1mA to 100mA,
V
IN
= V
OUT(NOM)
+ 6V
PSRR
t
START
OV
TH
I
LOAD
= 10mA, f
IN
= 100Hz, 500mV
P-P
From ENABLE high to OUT,
I
LOAD
= 100mA
I
SINK
= 1mA (from OUT)
OUT = OUT
(NOM)
x 1.15
1.07 x
V
OUT
5
70
180
1.1 x
V
OUT
10
LOGIC INPUT (ENABLE, ENABLE1, ENABLE2,
HOLD)
V
IL
V
IH
ENABLE, ENABLE1, ENABLE2
ENABLE, ENABLE1, ENABLE2
ENABLE, ENABLE1, ENABLE2 are
internally pulled down to GND
1.8V
≤
V
OUT
≤
11V
1.8V
≤
V
OUT
≤
11V
HOLD
is internally pulled up to OUT
4.500
4.250
2.970
2.805
2.250
2.125
1.620
1.530
OUT -
0.4
1.8
4.625
4.375
3.053
2.888
2.313
2.188
1.665
1.575
4.750
4.500
3.135
2.970
2.375
2.250
1.710
1.620
3
0.4
1.4
0.6
0.4
V
V
µA
V
IH
V
µA
V
MAX6765–MAX6774
Automotive Micropower Linear Regulators
with Supervisor
ELECTRICAL CHARACTERISTICS (continued)
(V
IN
= 14V, C
IN
= 0.1µF, C
OUT
= 10µF, T
A
= T
J
= -40°C to +125°C, unless otherwise noted. Typical values are at T
A
= T
J
= +25°C.)
(Note 1)
PARAMETER
RESET
Threshold (Adjustable
Output Voltage)
RESETIN Input Current
SYMBOL
CONDITIONS
L/T/Z/W, SET = resistive divider,
RESET
falling
M/S/Y/V, SET = resistive divider,
RESET
falling
V
RESETIN
= V
GND
or 12V
V
TH
= 87.5% of V
SET
(M/S/Y/V),
RESET
falling
V
TH
= 92.5% of V
SET
(L/T/Z/W),
RESET
falling
V
OUT
falling
RESETIN falling
D0
RESET
Timeout Period (TIMEOUT
Connected to OUT)
D1
V
OUT
rising
D2
D3
D4
TIMEOUT Ramp Current
TIMEOUT Ramp Threshold
L/M/T/S options
V/W/Y/Z options
V
OUT
≥
1.8V, I
SINK
= 50µA,
RESET
asserted
V
OUT
≥
1.8V, I
SINK
= 3.2mA,
RESET
asserted
V
OUT
≥
1.8V, I
SOURCE
= 250µA,
RESET
not asserted
RESET
not asserted,
RESET
= 12V
t
WDI
V
IL
V
IH
V
IL
I
WDI
t
WD
1.8V
≤
V
OUT
≤
11V
1.8V
≤
V
OUT
≤
11V
1.8V
≤
V
OUT
≤
11V
1.8V
≤
V
OUT
≤
11V
V
WDI
= 0V or V
WDI
= 12V
MAX6773/MAX6774
MAX6773B/MAX6774B
-1
1.12
40
1.6
50
V
OUT
- 0.4V
0.4
+1
2.08
60
1
0.4
0.8 x
V
OUT
100
2.187
8.75
35
140
800
1.160
1.060
MIN
V
OUT
x
0.9
V
OUT
x
0.85
-100
1.057
1.118
1.085
1.147
0.3
35
75
3.125
12.5
50
200
1000
1.220
1.170
4.063
16.25
65
260
1200
1.259
1.242
0.3
V
0.4
V
nA
µs
V
V
V
µA
s
ms
nA
V
ms
TYP
V
OUT
x
0.925
V
OUT
x
0.875
MAX
V
OUT
x
0.950
V
OUT
x
0.900
+100
1.112
V
1.176
µs
µs
µs
UNITS
V
nA
RESETIN Threshold
OUT to
RESET
Delay
RESETIN To
RESET
Delay
RESET
Output-Voltage Low
(Open Drain or Push-Pull)
RESET
Output-Voltage High
(Push-Pull)
RESET
Open-Drain Leakage
Current
Watchdog Minimum Input Pulse
Watchdog Input Low Voltage
Watchdog Input High Voltage
Watchdog Input Low Voltage
Watchdog Input Current
Watchdog Timeout Period
V
OL
V
OH
Note 1:
Production tested at T
A
= +25°C. Overtemperature limits are guaranteed by design.
Note 2:
Device tested at internally set voltage.
Note 3:
Dropout voltage for L/M versions is defined as (V
IN
- V
OUT
) when V
OUT
equals 98% of the nominal value of V
OUT
when
V
IN
= 11V. For T/S versions, dropout voltage is defined as (V
IN
- V
OUT
) when V
OUT
equals 98% of the nominal value of V
OUT
when V
IN
= 9.3V.
Note 4:
Observe the absolute maximum power dissipation limits.
Targeted Design Platform White Paper.pdf For more than twenty-five years, Xilinx has been at the forefront of the programmable logic revolution, inventing and evolving FPGA platform technology. During...
I have an official version of the FPGA development board, which has 35,000 LUTs (LEs), 2 Gigabit Ethernet, 128MB of DDR3 SDRAM, a digital tube, N LEDs, an integrated USB burner, and supports PCI-expre...
[font=宋体]Watching time is an extremely important performance indicator in any mobile multimedia device because it represents not only how much energy the battery stores, but also how efficiently the e...
I just started learning coding and my coding skills are not good. Now I have a problem that I don't understand. I need to use the GSM module to send data to the server. The data is provided by stm32. ...
Emergency hand-held lamps powered by 6V maintenance-free batteries are widely used in rural areas. The charger used is a transformer step-down and single diode half-wave rectifier, and the charging...[Details]
introduction
Since the beginning of the 21st century, the world of information has changed rapidly. Maybe a high-tech product will be released today and a better similar product will be releas...[Details]
In recent years, the market for mobile/portable devices such as smartphones and laptops has continued to grow rapidly. While these products continue to integrate more new features to enhance the ...[Details]
1. Introduction
Light control circuit plays a vital role in urban street lamps or corridor lighting. With light control circuit, the lights can be automatically turned on and off according to ...[Details]
introduction
For the voltage regulator modules (VRMs) that power the latest computer central processing units (CPUs), power supply designers have historically used multiphase interleaved b...[Details]
Battery life is critical for portable applications. For applications such as smoke detectors, security devices, and thermostats, factory-installed batteries need to last for more than 10 years. The...[Details]
1. Introduction to CIF Board
Fieldbus integration based on PC system
Whether it is a master or a slave, fieldbus has won unanimous praise in the field of PC-based automation. For more...[Details]
General LED lighting has a current limiting resistor in the driving circuit, and the power consumed by the resistor has nothing to do with the LED light emission. In order to improve efficiency, a...[Details]
Among the many members of the single-chip microcomputer family, the MCS-51 series of single-chip microcomputers has occupied the main market of industrial measurement and control and automation eng...[Details]
From the previous section, we have learned that the timer/counter in the microcontroller can have multiple uses, so how can I make them work for the purpose I need? This requires setting the timer/...[Details]
Problems such as the depletion of natural resources, air pollution, traffic congestion, and rising fossil fuel prices have forced societies and individuals to seek alternative means of transportati...[Details]
Motors, especially those with brushes, generate a lot of noise. This noise must be dealt with if the appliance is to meet the requirements of EMC standards. The means to solve EMC are nothing more ...[Details]
Introduction
As the country increases its efforts to control the atmospheric environment, motorcycle emission regulations will become stricter year by year, and motorcycles that do not meet the...[Details]
Currently, each country is developing its own USB interface
charging specifications
, which leads to a major problem that a USB interface
charging
device manufactured in one country...[Details]
1. Proposal of
reconfigurable
measurement and control system
The measurement and control system generally refers to a system based on
computers
to realize data acquisition a...[Details]