FCPT-124211455

Description
Fiber Optic Device, 1530nm Min, 1570nm Max, SC/APC Connector
CategoryWireless rf/communication    Optical fiber   
File Size539KB,2 Pages
ManufacturerLaser Components USA Inc.
Environmental Compliance  
Download Datasheet Parametric View All

FCPT-124211455 Overview

Fiber Optic Device, 1530nm Min, 1570nm Max, SC/APC Connector

FCPT-124211455 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Objectid1335672111
Reach Compliance Codeunknown
Communication standardsTELCORDIA-GR-1209
Connection TypeSC/APC CONNECTOR
Fiber optic equipment typesMEDIA CONVERTER
Fiber typePMF
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
Maximum operating wavelength1570 nm
Minimum operating wavelength1530 nm
Nominal operating wavelength1550 nm
minimum return loss50 dB
1×2(2×2) Fused
Polarization
Maintaining
Compact Fiber Tap
(patent pending)
Product Description
The compact-sized fused polarization maintaining fiber tap comes
with low excess loss, high extinction ratio, high optical power handling
and Telcordia GR-1209 compliant test. It has wide range of
applications such as optical amplifier, power monitoring, telecomm
system and testing equipment.
Features
Low Excess loss
High Extinction Ratio
High Power Handling
Telcordia GR-1209
Compliant
Performance Specifications
Hybrid PM Fiber Tap
Operation Wavelength
Port Configuration
Excess Loss (Typical)
Excess Loss (Maximum)
PER for Through Port (Minimum)
Return Loss* (Minimum)
Directivity* (Minimum)
≤0.3
≤0.5
≥20
≥50
≥55
≤2
-40 ~ +85
-50 ~ +85
∅3.0
x L54
Specification
Premium
A grade
Unit
nm
1550/1480/1310
±
20
1×2
≤0.5
≤0.7
≥17
dB
dB
dB
dB
dB
W
o
C
o
C
Applications
Optical Amplifier
Power Monitoring
Telecomm System
Testing Equipment
Operating Power (Maximum)
Operating Temperature
Storage Temperature
Package Type
mm
* Test at central wavelength only
All specification are based on slow-axis alignment and without connector
LASER COMPONENTS GmbH
Werner-von-Siemens-Str. 15, 82140 Olching, Germany, Phone: +49 8142 2864 0, Fax: +49 8142 2864 11, info@lasercomponents.com
Synplify Tool User Guide.pdf
Synplify Tool User Guide.pdf...
zxopenljx FPGA/CPLD
Is it necessary to set the layer thickness in the stack management when designing a 4-layer PCB in AltiumDesigner?
I have never drawn a 4-layer PCB before. I saw that the thickness of each layer can be set in the stack management. When sending it to the manufacturer for production, I can't just tell them whether i...
littleshrimp PCB Design
at+cipstart="tcp","210.153.49.2","80" ERROR What's going on?
AT+CGATT=1 OK AT+CGDCONT=1,"IP","CMWAP" OK AT+CGACT=1,1 OK AT+CGPADDR=1 +CGPADDR: 1,"10.177.14.204"OK AT+CGDATA=1 CONNECT 115200 ~ }#?}!}!} }6}!}$}%軁"}&} } } } }'}"}(}"}#}$?&磣~ }#?}!}!} }6}!}$}%軁"}&} ...
citylove Embedded System
Why is the output not 7.5V?
[i=s] This post was last edited by paulhyde on 2014-9-15 09:33 [/i] As shown in the picture: 7805 outputs 5V, TL431 should output 2.5v, and the final output should be 5+2.5=7.5v. However, the multimet...
江汉大学南瓜 Electronics Design Contest
Please ignore the points. Please ignore the points.
Just for points, please ignore...
bds489550896 Embedded System
EPM7128SLC84-15
[i=s]This post was last edited by paulhyde on 2014-9-15 09:14[/i] EPM7128SLC84-15...
wangwei20060608 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2496  2618  1588  2868  1351  51  53  32  58  28 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号