Operating Temperature Range ......................... -40°C to +125°C
Junction Temperature ......................................................+150°C
Storage Temperature Range ............................ -65°C to +150°C
Lead Temperature (soldering, 10s) ................................. +300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these
or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to absolute maximum rating conditions for extended periods may affect
device reliability.
Electrical Characteristics
(V
CC
= +4.25V to +5.5V for L/M versions, V
CC
= +2.55V to +3.6V for the T/S/R versions, V
CC
= +2.1V to +2.75V for the Z/Y versions.
T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
PARAMETER
Operating Voltage Range
Supply Current
MR
Unconnected
SYMBOL
V
CC
CONDITIONS
T
A
= 0°C to +125°C
T
A
= -40°C to +125°C
V
CC
< 5.5V, no load
I
CC
V
CC
< 3.6V, no load
V
CC
< 3.6V, no load (MAX6708 only)
MAX670_L/MAX670_AL
MAX670_M/MAX670_AM
MAX670_T/MAX670_AT
V
CC
Reset Threshold
(V
CC
falling)
V
TH
MAX670_S/MAX670_AS
MAX670_R/MAX670_AR
MAX670_Z/MAX670_AZ
MAX670_Y/MAX670_AY
Reset Threshold
Temperature Coefficient
V
CC
to Reset Output Delay
Reset Timeout Period
V
CC
Falling to
WDO
Delay
PFI, RST_IN1, RST_IN2
Threshold
PFI Hysteresis
t
RP
∆V
TH
V
CC
falling at 10mV/µs
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
MAX6701(A)/MAX6702(A)/MAX6703(A)/MAX6705(A)/
MAX6706(A)/MAX6707(A)
V
CC
= 1.8V to 5.5V
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
602
593
6
140
120
5
618
634
642
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
4.50
4.47
4.25
4.22
3.00
2.97
2.85
2.83
2.55
2.53
2.25
2.24
2.12
2.11
60
12
200
280
300
2.19
2.32
2.63
2.93
3.08
4.38
MIN
1.0
1.2
12
9
6
4.63
TYP
MAX
5.5
5.5
25
20
20
4.75
4.78
4.50
4.53
3.15
3.17
3.00
3.02
2.70
2.72
2.38
2.40
2.25
2.27
ppm/°C
µs
ms
µs
mV
mV
V
µA
UNITS
V
www.maximintegrated.com
Maxim Integrated
│
2
MAX6701-08/
MAX6701A-03A/
MAX6705A-07A
Low-Voltage, SOT23 µP Supervisors with Power-Fail
In/Out, Manual Reset, and Watchdog Timer
Electrical Characteristics (continued)
PARAMETER
PFI, RST_IN1, RST_IN2
Leakage Current
PFI to
PFO
Delay
MR
Input Voltage
MR
Minimum Input Pulse
MR
Glitch Rejection
MR
to Reset Delay
V
CC
Rising to
WDO
Delay
MR
Pullup Resistance
Watchdog Timeout Period
WDI Pulse Width
WDI Input Voltage
WDI Input Current
t
WD
t
WDI
V
IL
V
IH
I
WDI
t
MD
t
PF
V
IL
V
IH
SYMBOL
(Note 2)
(V
CC
= +4.25V to +5.5V for L/M versions, V
CC
= +2.55V to +3.6V for the T/S/R versions, V
CC
= +2.1V to +2.75V for the Z/Y versions.
T
A
= -40°C to +125°C, unless otherwise specified. Typical values are at T
A
= +25°C.) (Note 1)
CONDITIONS
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
MIN
-50
-200
1
0.3 x V
CC
0.7 x V
CC
1
100
200
MAX6701(A)/MAX6702(A)/MAX6703(A)/
MAX6705(A)/MAX6706(A)/MAX6707(A)
25
T
A
= -40°C to +85°C
T
A
= -40°C to +125°C
(Note 2)
1.12
0.96
50
0.3 x V
CC
0.7 x V
CC
V
WDI
= 0V or V
CC
V
CC
≥ 1.0V, I
SINK
= 50µA, output asserted
(T
A
= 0°C to +125°C)
V
OL
V
CC
≥ 1.2V, I
SINK
= 100µA, output asserted
V
CC
≥ 2.55V, I
SINK
= 1.2mA, output asserted
V
CC
≥ 4.25V, I
SINK
= 3.2mA, output asserted
PFO Output Low
(Push-Pull or Open Drain)
RESET, WDO, PFO
Output
High (Push-Pull Only)
RESET, WDO, PFO
Output Open-Drain
Leakage Current
V
OL
V
OH
I
LKG
V
CC
≥ 2.55V, I
SINK
= 1.2mA, output asserted
V
CC
≥ 4.25V, I
SINK
= 3.2mA, output asserted
V
CC
≥ 1.80V, I
SINK
= 200µA, output asserted
-1
+1
0.3
0.3
0.3
0.4
0.3
0.3
0.4
0.8 x V
CC
0.8 x V
CC
1.0
0.8 x V
CC
0.8 x V
CC
0.8 x V
CC
0.8 x V
CC
0.3
0.4
V
V
V
µA
V
V
100
50
1.6
75
2.4
2.52
TYP
MAX
+50
+200
UNITS
nA
µs
V
µs
ns
ns
ns
kΩ
s
ns
V
µA
RESET, WDO Output Low
(Push-Pull or Open Drain)
V
CC
≥ 2.7V, I
SOURCE
= 500µA, output not asserted
V
CC
≥ 4.75V, I
SOURCE
= 800µA, output not asserted
V
CC
> VTH, output not asserted
V
CC
≥ 1.0V, I
SOURCE
= 1µA, reset asserted
(T
A
= 0°C to +125°C)
RESET Output High
(Push-Pull Only)
V
OH
V
CC
≥ 1.2V, I
SOURCE
= 50µA, reset asserted
V
CC
≥ 2.55V, I
SOURCE
= 500µA, reset asserted
V
CC
≥ 4.25V, I
SOURCE
= 800µA, reset asserted
V
CC
≥ 2.7V, I
SINK
= 1.2mA, reset not asserted
RESET Output Low
(Push-Pull Only)
V
OL
V
CC
≥ 4.75V, I
SINK
= 3.2mA, reset not asserted
Note 1:
Over-temperature limits are guaranteed by design and not production tested. Devices are tested at T