Glass tube, nickel-plated brass endcap construction
UL Listed product meets standard 248-14
UL Listed Card: AGC
1
⁄
20
-10
UL Recognition Card: AGC 11-40
CSA Component Acceptance Card (Class No. 1422 30)
CSA Certification Card (Class No. 1422 01)
Agency Information
Environmental Data
• Shock:
1
⁄
20
-
3
⁄
4
A – MIL-STD-202, Method 213, Test Condition I; 1 - 30A –
MIL-STD-202, Method 207, (HI Shock)
• Vibration:
1
⁄
20
- 30A – MIL-STD-202,Method 204, Test Condition A
(Except 5g, 500Hz)
Ordering
• Specify packaging code prefix, part number and option code suffix
(if applicable)
Specifications
• See page 2
1113
BU-SB131067
Page 1 of 3
Data Sheet 2543
Non-RoHS
Part Number
AGC-
1
⁄
20
AGC-
1
⁄
10
AGC-
1
⁄
8
AGC-
3
⁄
16
AGC-
2
⁄
10
AGC-
1
⁄
4
AGC-
3
⁄
10
AGC-
3
⁄
8
AGC-
1
⁄
2
AGC-
3
⁄
4
AGC-1
AGC-1-
1
⁄
4
AGC-1-
1
⁄
2
AGC-2
AGC-2-
1
⁄
4
AGC-2-
1
⁄
2
AGC-3
AGC-4
AGC-5
AGC-6
AGC-7
AGC-7-
1
⁄
2
AGC-8
AGC-9
AGC-10
AGC-12
AGC-14
AGC-15
AGC-20
AGC-25
AGC-30
AGC-35
AGC-40
RoHS
Part Number
AGC-
1
⁄
20
-R
AGC-
1
⁄
10
-R
AGC-
1
⁄
8
-R
AGC-
3
⁄
16
-R
AGC-
2
⁄
10
-R
AGC-
1
⁄
4
-R
AGC-
3
⁄
10
-R
AGC-
3
⁄
8
-R
AGC-
1
⁄
2
-R
AGC-
3
⁄
4
-R
AGC-1-R
AGC-1-
1
⁄
4
-R
AGC-1-
1
⁄
2
-R
AGC-2-R
AGC-2-
1
⁄
4
-R
AGC-2-
1
⁄
2
-R
AGC-3-R
AGC-4-R
AGC-5-R
AGC-6-R
AGC-7-R
AGC-7-
1
⁄
2
-R
AGC-8-R
AGC-9-R
AGC-10-R
AGC-12-R
AGC-14-R
AGC-15-R
AGC-20-R
AGC-25-R
AGC-30-R
AGC-35-R
AGC-40-R
AC Voltage
Rating
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
32
32
32
32
32
32
32
32
SPECIFICATIONS
AC Interrupting Rating (amps)
250
125
32
35
10,000
—
35
10,000
—
35
10,000
—
35
10,000
—
35
10,000
—
35
10,000
—
35
10,000
—
35
10,000
—
35
10,000
—
35
10,000
—
35
10,000
—
100
10,000
—
100
10,000
—
100
10,000
—
100
10,000
—
100
10,000
—
100
10,000
—
200
10,000
—
200
10,000
—
200
10,000
—
200
10,000
—
200
10,000
—
200
10,000
—
200
10,000
—
200
10,000
—
—
—
1000
—
—
1000
—
—
1000
—
—
1000
—
—
1000
—
—
1000
—
—
70
—
—
80
Typical DC Cold
Resistance* (Ω)
4.500
12.565
6.800
4.900
3.360
2.300
1.670
1.203
0.615
0.312
0.190
0.145
0.115
0.078
0.067
0.057
0.045
0.030
0.024
0.020
0.017
0.0146
0.014
0.012
0.008
0.0070
0.0062
0.006
0.004
0.003
0.002
0.0014
0.0019
Typical Melting
I
2
t
†
AC
0.00773
0.000787
0.00131
0.00637
0.00435
0.0148
0.0208
0.0321
0.269
0.815
1.615
0.018
0.0149
0.00509
0.00588
0.00879
0.0167
0.0305
0.045
0.071
0.105
—
0.152
0.21
0.492
—
—
0.566
1.438
2.109
3.807
—
—
Typical Voltage
Drop
‡
0.67
6.00
4.67
4.12
4.51
0.89
2.88
4.59
0.59
0.37
0.31
0.35
0.27
0.28
0.26
0.31
0.25
0.22
0.23
0.23
0.23
—
0.19
0.18
0.20
—
—
0.14
0.12
0.11
0.12
—
—
* DC Cold Resistance (Measured at ≤10% of rated current)
† Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage.)
‡ Typical Voltage Drop (Voltage drop was measured at 25°C ambient temperature at rated current)
1113
BU-SB131067
Page 2 of 3
Data Sheet 2543
Time-Current Curves
TIME IN SECONDS
CURRENT IN AMPERES
Packaging Code Prefix
Code
BK
BK1
BK8
Code
B
V
-R
Description
100 pieces of fuses packed into a cardboard carton with flaps folded
1000 pieces of fuses packed into a cardboard carton with flaps folded
8000 pieces of fuses packed into a cardboard carton with flaps folded
Option Code Suffix
Description
Board Washable - Hermetically sealed to withstand aqueous cleaning
Axial leads - copper tinned wire with nickel-plated brass overcaps
RoHS Compliant version
The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended
to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or
construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin.
Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life support systems
are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result in significant
[i=s] This post was last edited by 5525 on 2016-5-29 16:24 [/i] [size=5]Automatic control specifications for automotive air conditioners [/size][size=4]I. Refrigeration function [/size]1. Refrigeratio...
As the title says, I am practicing the basic design of menus. I would like to ask experts how to load two menus in one window, that is, the lower left and lower right corners of the mobile phone scree...
When the serial port receives data, it loads the data from the buffer into the array. However, the length of the data we receive is not certain. If a length is set, but the actual length of the data s...
I want the Chinese version of the book "NT File System Insider" for extra points or cash. Both electronic and printed versions are available at tao_ao@126.com...
1. Several nouns
ABI:
The specifications that an executable file must follow in order to run in a specific execution environment;
Separately generated relocatabl...[Details]
According to foreign media reports, Ford Motor has applied to the U.S. Patent and Social Security Administration (USPTO) for a patent for a remote vehicle control system that may be used in future ...[Details]
Whether it is an electric car or an ordinary fuel car, for the vast majority of car buyers, the final cost of use is what they care about most. For fuel cars, how to save fuel is what drivers care ...[Details]
Definition of interactive projection system:
Interactive projection systems, also known as multimedia interactive projection, are available in floor, wall, and tabletop interactive projection....[Details]
On August 18th, Galaxis, a specialist in integrated intelligent intralogistics robotics, officially unveiled its next-generation, ultra-narrow aisle forklift mobile robot, the "VFR Ultra-Narrow Ser...[Details]
Have you ever heard stories about "crazy appliances"? Think of microwaves that turn on automatically or ovens that preheat without any human input? With radios and electromagnetic interfaces ubiqui...[Details]
A half-bridge is an inverter topology for converting DC to AC. A typical half-bridge circuit consists of two controller switches, a three-wire DC power supply, two feedback diodes, and two capacito...[Details]
In the electronics manufacturing industry, surface mount technology (SMT) placement machines are core equipment for production lines. However, with many different models available on the market, ch...[Details]
Recently, Joyson Electronics has made positive progress in the core technology research and development of the robot's "brain and brain" and key components, and launched the industry's first integr...[Details]
To improve the lateral active safety of intelligent connected vehicles, the identification and definition of unexpected functional safety scenarios for the EPS (Electronic Steering System) ...[Details]
Tools/Materials
Yitong Chuanglian MODBUS to PROFIBUS Gateway YT-PB-03
Siemens s7-300
This article describes how to configure the YT-PB-03 MODBUS to PROFIBUS gat...[Details]
When American cartoonist Chester Gould sketched the watch on Dick Tracy's wrist, he had no idea that science fiction would become reality 70 years later. As a comic strip artist, Gould imagined fut...[Details]
introduction
The widespread use of air conditioner communication circuits began with the rise of household inverter air conditioners. With China's energy conservation and emission reduction in...[Details]
The power transmission system between a car's engine and drive wheels is called its drivetrain. It ensures the necessary traction and speed under various driving conditions, and coordinates these t...[Details]
Today, the voltage of electronic products continues to rise to 400V, 600V and even 1000V, so there are few electronic load models that can handle such high voltages. Many people consider connecting...[Details]