EEWORLDEEWORLDEEWORLD

Part Number

Search

KLKR.250T

Description
industrial & electrical fuses .25a 600vac 300vdc fast acting
CategoryCircuit protection    Circuit protection   
File Size97KB,4 Pages
ManufacturerLittelfuse
Websitehttp://www.littelfuse.com
Download Datasheet Parametric View All

KLKR.250T Overview

industrial & electrical fuses .25a 600vac 300vdc fast acting

KLKR.250T Parametric

Parameter NameAttribute value
MakerLittelfuse
Reach Compliance Codeunknow
Is SamacsysN
Fusing characteristicsFAST
body height38.1 mm
Body length or diameter10.3 mm
Circuit protection typeElectric Fuse
Fuse typeCC
physical size10.3mm x 38.1mm
Rated breaking capacity200000 A
Rated current0.25 A
Rated voltage600 V
GuidelineCE, CSA, UL
Base Number Matches1
Cartridge and Axial Lead Fuses
Class CC* Fuses > CCMR, KLDR and KLKR Series
Class CC fuses
CCMR, KLDR and KLKR Series
Description
Fast-Acting KLKR fuses provide fast-acting protection to
equipment containing surge sensitive components. Use
KLKR Fuses for non-inductive loads not requiring time-
delay.
®
CCMR fuses (formerly KLMR) are specifically designed
to withstand sustained starting currents of small motors.
The CCMR Fuses provide short-circuit protection for motor
branch-circuits.
KLDR fuses are specifically designed to withstand
the momentary high magnetizing currents of control
transformers, solenoids, and similar inductive loads.
Ampere Range
Agency Approvals
Agency
Agency File Number
Electrical Characteristics for Series
% of Ampere
Rating
110%
135%
200%
Ampere Rating
0-30A
0-30A
0-30A
Opening Time
15 minutes, Minimum
1 hour, Maximum
4 minutes, Maximum
12 seconds, Minimum
E81895
0.1 - 30A (KLDR/KLKR)
0.2 - 60A (CCMR)
0.1 - 30A
®
LR 29862
Notes:
KLKR Series:
UL listed Fast-Acting Class CC per UL 248 and CSA Certified
KLDR Series:
UL listed Time-Delay Class CC per UL 248 and CSA Certified.
CCMR Series:
UL listed Time-Delay Class CC per UL 248 and CSA Certified,
and 35-60A UL Listed Time-Delay Class CD.
200% Time-delay
Dimensions
Product Characteristics
AC:
DC:
Voltage Rating
600 Volts
250 Volts (CCMR 0.2 – 2A)
(CCMR 4.5 – 10A)
(CCMR 35 – 60A)
300 Volts (CCMR 2.25 – 4A)
300 Volts (KLDR)
300 Volts (KLKR)
500 Volts (CCMR 2 - 30A)
38.1 mm
(1.50")
0-30A
6.4 mm
(.25")
10.3 mm
(.41")
12.7 mm
(.50")
3.2 mm
(.125")
KLKR - 0.1A - 30A
RoHS compliant items
CCMR - 25A and 30A
KLDR - 0.1A - 7
.5A, 25A and 30A
35-60A
21.6 mm
(.850")
47.8 mm
(1.880")
©2009 Littelfuse, Inc.
Specifications are subject to change without notice.
21
Revised: August 12, 2009
CCMR Series

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 938  2679  370  1252  1930  19  54  8  26  39 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号