EEWORLDEEWORLDEEWORLD

Part Number

Search

2636LP/3A22601L6V/6

Description
Rocker Switch, SPDT, Latched, 15A, 12VDC, Quick Connect Terminal, V-shaped Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size230KB,8 Pages
ManufacturerAPEM
Environmental Compliance
Download Datasheet Parametric View All

2636LP/3A22601L6V/6 Overview

Rocker Switch, SPDT, Latched, 15A, 12VDC, Quick Connect Terminal, V-shaped Rocker Actuator, Panel Mount

2636LP/3A22601L6V/6 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Actuator typeV-SHAPED ROCKER
body width18.5 mm
body height28.1 mm
Body length or diameter32 mm
Contact (AC) maximum rated R load16A@250VAC
Maximum contact current (AC)16 A
Maximum contact current (DC)15 A
Contact (DC) maximum rated R load15A@12VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)12 V
Electrical life10000 Cycle(s)
illuminationRED LAMP
Manufacturer's serial number2600
Installation featuresPANEL MOUNT
Maximum operating temperature125 °C
Minimum operating temperature-20 °C
method of packingBULK
surface mountNO
Switch actionLATCHED
switch functionSPDT
Switch typeROCKER SWITCH
Termination typeQUICK CONNECT
Base Number Matches1
2600 series
Illuminated and non-illuminated rocker switches
Distinctive features and specifications
Three rocker shapes : plain, V-shaped or concave
Various rocker colours
Frame with protection guard on 2600LP models
UL, CSA, VDE and NF (EN 61058-1) approved
ELECTRICAL SPECIFICATIONS
• Max. current/voltage rating with resistive load and approved ratings : see table below.
• Initial contact resistance : 10mΩ max. at 1A 2VDC
Models for peak currents
• Insulation resistance : 1.000 MΩ min. at 500VDC
Models 2600SLH with silver cadmium oxide contacts
• Dielectric strength : 2.500 Vrms 50 Hz min. between terminals
are discontinued. They will be replaced by switches
3.000 Vrms 50 Hz min. between terminals and metal panel
with silver tin oxide contacts.
• Electrical life : 10.000 cycles at full load
APPROVED RATINGS
FUNCTIONS
CSA
CSA 22-2
DIRECT CURRENT
NF
EN 61058-1
UL
UL 1054
VDE
EN 61058-1
24 VDC
12 VDC
D
ON - OFF
ON - ON
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
10A 125VAC
10A 250VAC
1/6 HP 250VAC
1/6 HP 125VAC
16A 125VAC
16A 250VAC
1/3 HP 250VAC
10A 125VAC
10A 250VAC
1/6 HP 125/250VAC
-
-
10(4)A 250VAC
T 85/55
-
10A
15A
ON - OFF - ON
ON - ON - ON
OTHERS
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
L I option
10(4)A 250VAC
-
L I option
10(4)A 250VAC
8A
5A
8A
10A
8A
10A
MATERIALS
GENERAL SPECIFICATIONS
• Case : melamine/polyester
• Frame : polyamide
• Actuator : polyamide
• Contacts :
A
: silver
C
: copper, silver plated
• Panel thickness : 0,8 mm to 4 mm (.031 to .157)
• Operating temperature :
- silver contacts (A) : -20°C to +125°C
- silver plated contacts (C) : -10°C to +55°C
AGENCY APPROVALS
EN 61058-1
EN 61058-1
Availability
: consult factory for details of approved models.
Marking
: approved models are standard marked.
APEM
www.apem.com
D-49
Intertek Electronics released the TX-2440A video tutorial - the complete version without deletions
Guo Tianxiang released the full set of 2440 videos. 8G 115 network disk has been downloaded. Please download it as soon as possible to avoid renewal.Intertek Electronics released the TX-2440A video tu...
zhanglu231123 ARM Technology
How does a trace moisture meter perform for factory equipment testing?
After choosing a trace moisture meter, you must want to test the performance of your factory equipment in time to understand whether it is within the correct and normal range. If not, you need to take...
ZXCQWEASD Test/Measurement
Reasons for leaving the company
[size=4]The new year has begun, and people are busy changing jobs and houses! [/size][align=left][size=4]There are many reasons for job hopping, which can be roughly divided into the following categor...
zhoouauruheng Talking about work
Question about application communicating with USB!
I want to write an application that communicates with the driver, mainly to read and write USB devices, so what does the application need to write?...
nov30th Embedded System
28335 1.8v power supply frequency problem
My 28335 is powered by 1.8V and configured to 150MHz. It feels very hot. The data sheet says that 1.8V power supply should be a 100MHz device. The TI forum said that my configuration will cause unknow...
malicious Microcontroller MCU
How to develop GPS module, just getting started,
I am new to GPS, so I want to buy a U-port GPS module, and then read the data through the GPS data interface protocol NMEA-0183. I wonder if there are any instructions to initialize it? Is it enough t...
malebanshee Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1686  993  1237  789  776  34  20  25  16  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号