Description
Power/Signal Relay, DPDT, Latched, 0.013A (Coil), 24VDC (Coil), 300mW (Coil), 1A (Contact), 110VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount
CategoryMechanical and electronic products    relay   
File Size101KB,5 Pages
ManufacturerRectron Semiconductor
Websitehttp://www.rectron.com/
Environmental Compliance
Download Datasheet Parametric View All

TN2-L2-H-24V-3 Overview

Power/Signal Relay, DPDT, Latched, 0.013A (Coil), 24VDC (Coil), 300mW (Coil), 1A (Contact), 110VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount

TN2-L2-H-24V-3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerRectron Semiconductor
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
body width5.6 mm
body height9.8 mm
Body length or diameter14 mm
Maximum coil current (DC)0.013 A
Coil operating voltage (DC)18 V
Coil power300 mW
Coil release voltage (DC)18 V
Coil resistance1920 Ω
Maximum coil voltage (DC)24 V
Coil/Input Power TypeDC
Contact (AC) maximum rated R load1A@125VAC
Maximum contact current (AC)1 A
Maximum contact current (DC)1 A
Contact (DC) maximum rated R load1A@110VDC
Maximum contact voltage (AC)125 V
Maximum contact voltage (DC)110 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Manufacturer's serial numberTN
Installation featuresTHROUGH HOLE-STRAIGHT MOUNT
operating hours3 ms
Maximum operating temperature70 °C
Minimum operating temperature-40 °C
method of packingBOX; TUBE
physical size14mm x 5.6mm x 9.8mm
GuidelineCSA; UL
Relay actionLATCHED
Relay functionDPDT
Relay typePOWER/SIGNAL RELAY
release time3 ms
surface mountNO
Termination typeSOLDER
Base Number Matches1
TN
SLIM POLARIZED RELAY
TN RELAYS
• Surge voltage withstand: 1500 V FCC
Part 68
• Self-clinching terminal also available
14
.551
5.6
.220
9.8
.386
FEATURES
• Small header area makes higher
density mounting possible
• High sensitivity: 140 mW nominal
operating power (single side stable
3-12 V type)
mm
inch
RoHS Directive compatibility information
http://www.nais-e.com/
SPECIFICATIONS
Contact
Arrangement
Initial contact resistance, max.
(By voltage drop 6 V DC 1A)
Contact material
Nominal switching capacity
(resistive load)
Max. switching power
(resistive load)
Max. switching voltage
Max. switching current
Min. switching capacity
(Reference value)
#1
Single side stable
Nominal
operating
power
1 coil latching
2 coil latching
Mechanical (at 180 cpm)
1 A 30 V DC
resistive load
Electrical
(at 20 cpm) 0.5 A 125 V AC
resistive load
2 Form C
60 mΩ
Gold-clad silver
1 A 30 V DC,
0.5 A 125 V AC
30 W, 62.5 VA
110 V DC,125 V AC
1A
10
µA
10 mV DC
140 mW (3 to 12 V DC)
200 mW (24 V DC)
300 mW (48 V DC)
100 mW (3 to 12 V DC)
150 mW (24 V DC)
200 mW (3 to 12 V DC)
300 mW (24 V DC)
10
8
2
×
10
5
10
5
Characteristics
Initial insulation resistance*
1
Between open
contacts
Initial
Between contact and
breakdown
coil
voltage
Between contact sets
FCC surge voltage between open
contacts
Temperature rise*
2
(at 20°C)
Operate time [Set time]*
3
(at 20°C)
Release time [Reset time]*
4
(at 20°C)
Functional*
5
Shock resistance
Destructive*
6
Functional*
7
Vibration resistance
Destructive
Conditions for
operation, transport
and storage*
8
(Not freezing and
condensing at low
temperature)
Unit weight
Ambient
temperature
Humidity
Min. 1,000 MΩ (at 500 V DC)
750 Vrms for 1 min.
(Detection current: 10 mA)
1,000 Vrms for 1 min.
(Detection current: 10 mA)
1,000 Vrms for 1 min.
(Detection current: 10 mA)
1,500 V
Max. 50°C
Max. 3 ms [Max. 3 ms]
Max. 3 ms [Max. 3 ms]
Min. 490 m/s
2
{50G}
Min. 980 m/s
2
{100G}
176.4 m/s
2
{18G}, 10 to 55 Hz
at double amplitude of 3 mm
294 m/s
2
{30G}, 10 to 55 Hz
at double amplitude of 5 mm
–40°C to +70°C
–40°F to +158°F
5 to 85% R.H.
Approx. 1.5 g .053
oz
Rating
Expected
life (min.
operations)
Note:
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load. (SX relays are available for low level load switching [10V DC, 10mA
max. level])
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage" section.
*
2
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
Nominal voltage applied to the coil, excluding contact bounce time without diode.
*
5
Half-wave pulse of sine wave: 11 ms; detection time: 10
µs.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10
µs.
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT .
All Rights Reserved © COPYRIGHT Matsushita Electric Works, Ltd.

Recommended Resources

[EEWORLD takes you DIY] Oscilloscope component list
Since we are not organizing a large-scale group purchase this time, I have not listed detailed price information. I have only listed the prices of some of the components I bought at that time for refe...
soso DIY/Open Source Hardware
What does the e73793836e41b1d26f52be19e89199e5 code mean?
What does the code e73793836e41b1d26f52be19e89199e5 mean?...
y0001 Talking
The scene of learning before the electronic design competition
Let's take a look at the photos of the lab when I participated in the electronic design competition: [size=12px][url=https://bbs.eeworld.com.cn/space.php?username=Sea_eeworld]Sea_eeworld[/url]Working ...
daicheng Embedded System
When CAN is initialized, while(CAN0CTL0_SYNCH == 0) loops infinitely
When CAN is initialized, while(CAN0CTL0_SYNCH == 0) loops infinitely. What is the reason? Please help me. I know it is because MSCAN is not synchronized with the CAN bus, but I don't know why. Can som...
socsic NXP MCU
I can't figure it out, need help, about the trigger clock source of ADC12 of MSP430F5438A
[size=4]When using MSP430F5438A ADC12, I want to use timer trigger to perform multi-channel multiple conversions, but the manual says that the clock source selection should refer to note B. I don't kn...
心相夕林 Microcontroller MCU
【Help】Questions about serial port
Now I use 4301471 to do dual machine communication, but I can monitor the data being sent, but the slave cannot receive it. I don't know what the problem is. The program is done according to the routi...
linglidu Microcontroller MCU

Popular Articles

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1142  1582  149  1636  1295  23  32  3  33  27 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号