EEWORLDEEWORLDEEWORLD

Part Number

Search

170M5243

Description
Electric Fuse, 450A, 1300VAC, 1300VDC, 100000A (IR), Inline/holder,
CategoryCircuit protection    Circuit protection   
File Size270KB,4 Pages
ManufacturerCooper Industries
Environmental Compliance
Download Datasheet Parametric View All

170M5243 Online Shopping

Suppliers Part Number Price MOQ In stock  
170M5243 - - View Buy Now

170M5243 Overview

Electric Fuse, 450A, 1300VAC, 1300VDC, 100000A (IR), Inline/holder,

170M5243 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCooper Industries
Reach Compliance Codecompliant
Is SamacsysN
Other featuresRATED BREAKING CAPACITY AT 1300 VDC: 100000 A
body width61 mm
body height61 mm
Body length or diameter80 mm
Built-in featuresINDICATOR
Circuit protection typeELECTRIC FUSE
Joule integral nominal34000 J
Manufacturer's serial number170M
Installation featuresINLINE/HOLDER
method of packingBOX
physical size80mm x 61mm x 61mm
Rated breaking capacity100000 A
Rated current450 A
Rated voltage (AC)1300 V
Rated voltage (DC)1300 V
GuidelineCE; DIN 43653; IEC; UL
surface mountNO
Terminal shapeTAB/BLADE
Base Number Matches1
High Speed Fuses
Square body DIN 43 653 — 1250V/1300V (IEC/UL):
50-1400A
1250V/1300V (IEC/UL) 50-1400A
Specifications
Description: Square body DIN 43
653 stud-mount high speed fuses.
Dimensions:
See dimensions
illustration.
Ratings:
Volts: —
Amps: —
IR: —
1250Vac (IEC)
1300Vac (UL)
50-1400A
100kA RMS Sym.
Arc Voltage
This curve gives the peak
arc voltage, UL, which may
1.8
1.4
appear across the fuse
during its operation as a
10
3
8
function of the applied
working voltage, Eg, (rms)
6
at a power factor of 15%.
5
4
3
2.5
UL
Power Losses
3
400
K
p
600
800
E
g
1000 1200 1400
Agency Information:
CE, Designed and tested to IEC
60269: Part 4, UL Recognized. Consult Cooper Bussmann for
UL Recognition/CSA Component Acceptance status.
Electrical Characteristics
Total Clearing I
2
t
2
The total clearing I t at
rated voltage and at power
factor of 15% are given in
the electrical characteris-
0.5
tics. For other voltages, the
0.4
clearing I
2
t is found by mul-
0.3
tiplying by correction factor,
K, given as a function of
0.2
applied working voltage,
400
Eg, (rms).
1.5
K
1.25
1.0
Watts loss at rated current
1.0
is given in the electrical
characteristics. The curve
0.8
0.6
allows the calculation of
0.5
the power losses at load
0.4
currents lower than the
rated current. The correc-
0.3
tion factor, Kp, is given as
0.2
a function of the RMS load
current, Ib, in % of the
rated current.
0.1
I
b
30 40 50
60
70
80 90 100%
Features and Benefits
• Excellent dc performance
• Low arc voltage and low energy let-through (I
2
t)
• Low watts loss
• Superior cycling capability
E
g
600 800 1000 1200 1400
Dashed lines (- - - - - -) apply to the
following amperages:.
Size
Amps.
1*
400A
1
500-630A
2
630-1000A
3
800-1400A
Typical Applications
• DC common bus
• DC drives
• Power converters/rectifiers
• Reduced voltage starters
Dimensions (mm)
Type -KN/110.
Size
1*
1
2
3
A
80
80
80
81
B
138
138
138
139
D
58
66
75
90
E
45
53
61
76
H
20
25
25
30
1mm = 0.0394” / 1” = 25.4mm
C
A
H
11
D
E
B
6
E
132
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 729  821  901  913  2012  15  17  19  41  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号