EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-111-49-1200LF

Description
Board Connector, 98 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle,
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

54122-111-49-1200LF Overview

Board Connector, 98 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Terminal, Locking, Black Insulator, Receptacle,

54122-111-49-1200LF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Objectid306024766
Reach Compliance Codecompliant
Country Of OriginFrance
ECCN codeEAR99
YTEOL9.1
body width0.19 inch
subject depth0.472 inch
body length4.9 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationAU ON NI
Contact completed and terminatedMatte Tin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialPOLYETHYLENE
JESD-609 codee3
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness30u inch
Rated current (signal)3 A
GuidelineUL, CSA
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts98
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
Design of Fully Digital Single-phase Three-level Rectifier Control Circuit
Abstract: Three-level rectifiers have attracted more and more attention due to their unique advantages. The working principle of three-level bridge rectifiers is introduced, and its control system is ...
zbz0529 Power technology
51 MCU timer initial value setting problem
I just came into contact with and learned 51. I saw that some timer initial value settings are TH0=(65536-50000)/256; TL0=(65536-50000)%256; some are TH0=0FCH TL0=66H. What is the difference between t...
zjjone1023 51mcu
44b0 How to write FIQ interrupt? Why do I still have an interrupt vector after 0x1c in my interrupt vector table?
1. How to write 44b0 FIQ interrupt? 2. Why is there still an interrupt vector after 0x1c in my interrupt vector table? How does this work? b InitialReg b Error_ISR b Error_ISR b Error_ISR b Error_ISR ...
weizhou Embedded System
Share the National University Mecha Masters Competition I watched yesterday
[i=s]This post was last edited by 寒冰翼love on 2019-8-9 17:32[/i]Yesterday, I went to watch the group stage of the 5th National University Mech Masters Competition in Shenzhen. Unfortunately, I didn’t h...
寒冰翼love Robotics Development
Learn to deal with several issues of power supply EMI - absolutely on point, with pictures and text
Learn to deal with several issues of power supply EMI - absolutely on point, with pictures and text :loveliness:High download rate... If you think it's good, give it a thumbs up, so that more people w...
czf0408 Power technology
Question: What does the linear address in cache mean?
As title...
converter Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1482  2175  402  1693  1544  30  44  9  35  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号