EEWORLDEEWORLDEEWORLD

Part Number

Search

ZWS240PAF36/A

Description
AC-DC Regulated Power Supply Module, 241.2W,
CategoryPower/power management    The power supply circuit   
File Size240KB,2 Pages
ManufacturerTDK-LAMBDA
Environmental Compliance
Download Datasheet Parametric View All

ZWS240PAF36/A Overview

AC-DC Regulated Power Supply Module, 241.2W,

ZWS240PAF36/A Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerTDK-LAMBDA
package instruction,
Reach Compliance Codecompliant
Is SamacsysN
Other featuresREMOTE SHUTDOWN
Analog Integrated Circuits - Other TypesAC-DC REGULATED POWER SUPPLY MODULE
CertificationCE, UL
Efficiency (main output)82%
high42 mm
Maximum input voltage265 V
Minimum input voltage85 V
length222 mm
Maximum grid adjustment rate0.4%
Maximum load regulation0.8%
Maximum operating temperature70 °C
Minimum operating temperature-10 °C
Maximum output current6.7 A
Nominal output voltage36 V
ProtectOUTPUT OVER CURRENT; OUTPUT OVER VOLTAGE
Maximum total power output241.2 W
width95 mm
Base Number Matches1
ZWS-PAF Series
150W to 480W Single Output Power Supplies
Features
Universal Input (85 - 265VAC)
Power factor Corrected
200% Peak Power capability
2 year warranty
Less than 0.5mA earth leakage current
Input Transient Protected
Key Market Segments & Applications
Specifications
Model
Input Voltage
Input Current (Forced air (1)
Inrush Current
(1,2)
Power Factor
Leakage Current
Temperature Coefficient
Overcurrent Protection
(3)
Overvoltage Protection
Hold Up Time (Typ) at 100VAC
Efficiency
Remote On/Off
Line Regulation
Load Regulation
Ripple & Noise
Operating Temperature
(4)
Operating Temperature
(4)
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
Conducted & Radiated EMI
Recommended EMI Filter
Immunity
Weight (Typ)
Size (WxHxD)
Warranty
-
A
A
-
mA
-
-
V
ms
%
-
%
%
%
°C
°C
°C
-
-
-
-
-
-
-
-
-
-
g
mm
yrs
ZWS150PAF
ZWS240PAF
85-265VAC (47-63Hz), 120-370VDC
2.8/1.4
4.0/2.0
14 / 28
0.99 at 100VAC, 0.95 at 200VAC, Meets EN61000-3-2
0.5mA Max. Typically 0.1mA (100VAC), 0.22mA (230VAC)
<0.02%/°C
>102% of peak current capability
24V: 30-35V, 36V: 43.2-50.4, 48V: 55.2-64.8V
20 (16ms at forced air power ratings)
82
See installation manual (Not available with /A cover option)
0.4%
0.8%
1%
(Open frame or L bracket) -10°C to +70°C, derate linearly to 70% load from 60°C to 70°C
(With /A cover option) -10°C to +60°C, derate linearly to 70% load from 50°C to 60°C
-30 to +85°C
Operating: 30 - 90% RH, Operating: 10 - 95% RH
Convection or Forced Air Cooled (1.5m/s)
Input to Ground 2kVAC (20mA), Input to Output 3kVAC (20mA),
Output to Ground 500VAC (100mA) for 1 min.
>100M at 25°C & 70% RH, Output to Ground 500VDC
10 - 55Hz (1 minute sweep), 19.6m/s
2
constant X, Y, Z 1 hour
< 196.1 m/s
2
UL60950-1, CSA60950-1, EN60950-1, EN50178, CE Mark
EN55022/EN55022-B, FCC Class B, VCCI-B
RSEL-2006W
EN61000-4-2, -3, -4, -5, -6, -8, -11
500g (800g with cover)
750g (1100g with cover)
See Outline Drawings
Two Years
Notes:
(1) 100/200VAC
(2) 25°C ambient (cold start)
(3) Avoid prolonged operartion in overload
(4) With 0.7m/s airflow. See derating table for convection cooling
1-800-526-2324 • www.us.tdk-lambda.com/lp/
176
Disclaimer: us.tdk-lambda.com/lp/legal.htm
Novice question: Under what circumstances can the driver that comes with WinCE be used?
The thing is, I was suddenly called to solve the driver problem of wince. I read many books, but there are many problems that I can't understand. The platform I use is pb4.2, and the following is the ...
Tiaholia Embedded System
Does anyone know a comparison table of shortwave antenna elevation height and propagation distance?
The main ones are dipole antenna and inverted V antenna. The inverted V antenna also has an angle parameter that can be indicated. Please provide a solution and give questions to experts....
yanwi RF/Wirelessly
Is it appropriate to use C# to develop wince6.0?
I feel that WINCE6.0's support for .NET is not perfect enough. Many classes are abstract classes, and many classes do not have any! I don't know whether it is suitable to use C# for development, or EV...
Nicjwwhg Embedded System
USB test source program
The key is to participate!...
rrhgrrhg Automotive Electronics
PCB board fault finding method
[align=left][color=rgb(255, 137, 102)][size=20px] PCB board fault finding method [/size][/color][/align] [align=left][color=rgb(62, 62, 62)][b]1. Measuring voltage method to find faulty PCB board [/b]...
ohahaha PCB Design
"Goodbye 2019, Hello 2020" + a little bit more improvement
In the past year: The company's key personnel who worked on hardware and backend management software left one after another. I was promoted from a bystander to a key member of the technical department...
hxm3000 Talking

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2780  932  187  130  1141  56  19  4  3  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号