EEWORLDEEWORLDEEWORLD

Part Number

Search

0249920000

Description
Modular Terminal Block, 20A, 2.5mm2, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size77KB,1 Pages
ManufacturerWeidmuller
Websitehttp://www.weidmuller.com/
Download Datasheet Parametric View All

0249920000 Online Shopping

Suppliers Part Number Price MOQ In stock  
0249920000 - - View Buy Now

0249920000 Overview

Modular Terminal Block, 20A, 2.5mm2, 1 Row(s), 1 Deck(s)

0249920000 Parametric

Parameter NameAttribute value
MakerWeidmuller
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Fastening methodSCREW
Manufacturer's serial numberMKL3/12
Number of layers1
Rows1
Number of channels12
Rated current20 A
Rated voltage400 V
safety certificateUL; CSA
Terminal and terminal strip typesMODULAR TERMINAL BLOCK
Conductor cross section2.5 mm2
Base Number Matches1
Multipole terminal blocks
Screw, solder, tab connection
MKL 2/12
MF 2/12
MKL 3/12
MKL 4/16
0241860000
0243620000
0262020000
0241760000
Dimensions/approvals
Width/length/height (mm)
Insulation stripping length/clamping screw/screwdriver blade
Rated data
Rated voltage*/current/cross-section
Rated impulse voltage VDE 0110/1.89/pollution severity
Further technical data
Tightening torque range
Nm
Torque setting with electric screwdriver type DMS 2
Clampable conductor
Solid H07V-U
mm
2
Stranded H07V-R
mm
2
Flexible H07V-K
mm
2
Flexible H07V-K and ferrule DIN 46 228/1
mm
2
Flexible H07V-K and ferrule with plastic insul. collar
mm
2
2
/plug gauge acc. to IEC 60 947-1 Size
Max. clamping range in mm
Rated data according to UL/CSA
Voltage/current/conductor size
Voltage/current/conductor size
Ordering data
Horizontal
Other number of poles on demand
0249920000
ar
110/23/16
5mm/M 2.5/3.5 x 0.6
400 V* / 20 A / 2.5/ 1.5/ 1 mm
2
6 kV/3
0.4…0.45
1
0.5…4
1.5…2.5
0.5…2.5
0.5…1.5
0.5…1.5
0.33...4.0 / A 2
0244320000
ar
103/24/16.5
5mm/M 2.5/3.5 x 0.6
400 V/20 A/2.5/1.5/1 mm
2
6 kV/3
0.4…0.45
1
0.5…4
1.5…2.5
0.5…2.5
0.5…1.5
0.5…1.5
0.33...4.0 / A 2
88/23/15
5 mm/M 2.5/3.5 x 0.6
125 V/20 A/2.5/1.5/1 mm
2
2.5 kV/3
0.4…0.45
1
0.5…2.5
1.5…2.5
0.5…2.5
0.5…2.5
0.5…2.5
0.2...2.5 / A 2
75/24/6
5 mm
63 V/17.5 A/1.5/1 mm
2
1.5 kV/3
UL
CSA
Versions
2-pole
4-pole
6-pole
12-pole
16-pole
Type
Cat. No.
Qty.
Type
Cat. No.
Qty.
MKL 2/12 PA
0241360000
50
300 V/25 A/22…12 AWG
300 V/25 A/22…12 AWG
Type
C tN .
a. o
Qty.
MKL3/2 KrG
0274920000**100
MKL 3/4KrG
0275120000**100
MKL 3/6 KrG
0275320000**
50
MKL 3/12KrG
0243620000**
20
300 V/25 A/22…12 AWG
150 V/15 A/22…12 AWG
Type
Cat. No.
Qty.
MKL 4/16 KrG
0262020000
1
)20
Vertical
Other number of poles on demand
2-pole
4-pole
6-pole
12-pole
16-pole
MKL 3/2 KrG
0276020000*
100
MKL 3/6 KrG
0276420000*
50
MKL3/12KrG
0249920000*
20
MKL 4/16 KrG
0244320000
20
double-sided 2.8 x 0 . 8
single-sided 0.8 x 1.6/2.8 x 0 . 8
MF 2/12 PA
0241860000
50
MF 2/12 PA
0241760000
50
* For terminals directly moun-
ted next to each other, the
rated voltage is reduced to
250 V.
** Rated voltage 250 V. For
terminals directly mounted
next to each other, the rated
voltage is reduced to 125 V.
Expansion rivet/insulation sleeve
SN
IH
Marking strips
printed
1…
BSTb 28/12
0245700000
50
bottom
top
0278500000
50
BSTb 28/4
0289800000
50
BSTb 28/6
0290000000
50
BSTb 28/12
0245900000
50
BSTb 28/16
0262200000
50
bottom
top
0200100000
500
IH 2.8
0386060000
100
unprinted
BSTo 28/12
0245600000
50
BSTo 28/4
0289300000
50
BSTo 28/6
0289500000
50
BSTo 28/12
0245800000
50
BSTo 28/16
0262100000
50
Mounting rails, end brackets, further marking material see “Accessories”
* Insulation sleeves are to be used for tab connections to maintain
the rated voltage.
170
1
)
Rated voltage 250 V
TC58CVG0S3HxAIx Engineering Data Sheet
TC58CVG0S3HxAIx Engineering Data Sheet Introducing Toshiba Memory Hardware Data Designing portable devices If you are interested in SoC, you can also chat with me....
王大壮 Embedded System
How to overcome the huge source of electromagnetic interference in adjacent circuits
[size=4]Single-ended data transmission uses only one signal line, whose potential is considered to be ground. While the signal line provides a forward path for the signal current, the ground line prov...
灞波儿奔 Analogue and Mixed Signal
Fluke's 70th anniversary thanksgiving and return, benefits are here!
[font=微软雅黑]My colleague shared the promotional information about Fluke's 70th anniversary thanksgiving feedback. I think it's pretty good, so I share it with you. If you have purchasing needs, you can...
eric_wang Talking
Ask for MC9S08QE128 program and information
Does anyone know how to use the MC9S08QE128 chip and write programs? Can you give me a simple program example? The one with pin definitions like 51. For example: The 51 program is as follows: The time...
思想者 Embedded System
stm32 systick always does not work, novice help
I'll post the code, please help me take a look, thanks in advance!main.c#include "main.h" GPIO_InitTypeDef GPIO_InitStructure; ErrorStatus HSEStartUpStatus;#define PC0_H GPIO_SetBits(GPIOC, GPIO_Pin_0...
zxz19890318 stm32/stm8
LPC1754 IAP program does not run in HyperTerminal? ? ?
I recently did an IAP upgrade, but I always felt that the program was downloaded (address starting from 0x10000), but the new program just wouldn't run. I posted the location where the Flash was writt...
BigLee1986 NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2544  732  208  2770  2229  52  15  5  56  45 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号