06-002.5-181AP

Description
Interconnection Device
CategoryThe connector    The connector   
File Size184KB,3 Pages
ManufacturerAries Electronics
Environmental Compliance
Download Datasheet Parametric View All

06-002.5-181AP Overview

Interconnection Device

06-002.5-181AP Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerAries Electronics
Reach Compliance Codecompliant
ECCN codeEAR99
Is SamacsysN
Other featuresPOLARIZATION AVAILABLE, 94V-0
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
Series 181 Thru 183
90° Pin Staked Flex Jumpers
FEATURES:
• Aries 90° Pin Staked Flex Jumpers combine thin, flexible, solid Copper conductors
embedded between layers of tough, flexible, flame-retardant insulation.
• Consult factory for cable lengths under 2.000 [50.80].
• See Data Sheet
11005
for Flat Pin Staked Flex Jumpers
GENERAL SPECIFICATIONS:
• Standard cable insulation is white UL VW-1, Style 2643 flame retardant Polyester
(Mylar) adhesive.
• High temperature flame retardant cable insulation is Polyimide (Kapton) insulation
with acrylic adhesive.
• Cable conductors are solid Copper with a cross-sectional area equivalent to that
of 26 gauge AWG.
• Female housing is black UL 94V-0 Glass-filled Stanyl 4/6 Nylon.
• Female and male “crimp-on” pins are spring-tempered Copper Alloy 510.
• Female and male pin plating:
T
= 100μ” [2.54μm] min. Matte Tin per ASTM-B545-97 over 50μ” Min. Nickel per
ASTM-AMS-QQ-N-290
TL
= 100μ” [2.54μm] min. 93/7 Tin/Lead per SAE-AMS-P-81728 over 50μ”
[1.27μm] min. Nickel per SAE-AMS-QQ-N-290.
• Cable current rating=3 Amps
• Cable voltage rating=300 Volts
• Cable dielectric strength=2500 Volts/mil, minimum (standard)
=4000 Volts/mil, minimum (high temp)
• Cable insulation resistance=1000 MOhms minimum (standard)
=100,000 MOhms (high temp)
•Conductor/Contact Resistance (avg.) = 20mOhms initial (max. 20mOhm increase)
based on a 2”cable @20°C.
•Operating temperature=67 to 257°F [-55 to 105°C].
• Female housing accepts leads .024-.030 [.61-.76] square,
.150 [3.81] long minimum.
MOUNTING CONSIDERATIONS:
• Suggested PCB hole size=.032+ .002 .81 + .05] dia.
No. of Conductors:
(4 – 40)
Cable Length:
“L” in inches
(2” min. length)
Ex: -0002- = 2”
-02.5 = 2.5”
Jumper Series:
181: Male both ends
182: Male/Female (tin)
183: Female (tin) both ends
XX-XXXX-181A
XX-XXXX-181AP
XX-XXXX-181ATL
XX-XXXX-181AHT
XX-XXXX-181APTL
XX-XXXX-181APHT
XX-XXXX-181APTLHT
XX-XXXX-181B
XX-XXXX-181BP
XX-XXXX-181BTL
XX-XXXX-181BHT
XX-XXXX-181BPTL
XX-XXXX-181BPHT
XX-XXXX-181BPTLHT
XX-XXXX-181C
XX-XXXX-181CP
XX-XXXX-181CTL
XX-XXXX-181CHT
XX-XXXX-181CPTL
XX-XXXX-181CPHT
XX-XXXX-181CPTLHT
XX-XXXX-182A
XX-XXXX-182AP
XX-XXXX-182ATL
XX-XXXX-182AHT
XX-XXXX-182APTL
XX-XXXX-182APHT
XX-XXXX-182APTLHT
XX-XXXX-182B
XX-XXXX-182BP
XX-XXXX -182BTL
XX-XXXX-182BHT
XX-XXXX-182BPTL
XX-XXXX-182BPHT
XX-XXXX-182BPTLHY
XX-XXXX-182C
XX-XXXX-182CP
XX-XXXX-182CTL
XX-XXXX-182CHT
XX-XXXX-182CPTL
XX-XXXX-182CPHT
XX-XXXX-182CPTLHT
Note: Aries specializes in custom design and production. In addition to
the standard products shown on this page, special materials, platings,
sizes, and configurations can be furnished, depending on quantities.
Aries reserves the right to change product specifications without notice.
A
LL DIMENSIONS
:
INCHES
[
MILLIMETERS
]
All tolerances
+ .005 [.13] unless otherwise specified
Kapton is a registered trademark for DuPont
**Aries reserves the right to ship with
or without a polarization stripe unless
otherwise specified by customer
“A”=NO. OF CONDUCTORS X .100 [2.54]
“B”=(NO. OF CONDUCTORS -1) X .100 [2.54]
ORDERING INFORMATION
XX-XXXX-18X X X XX XX
“HT”=High temperature cable insulation
“TL” = Tin/Lead Plating
“P”=Polarization stripe included
Bend Options:
“A” = Both ends bent 90?, same direction
“B” = One male end bent 90?
“C” = Both ends bent 90?, opposite direction
“D” = One female end bent 90?
XX-XXXX -182D
XX-XXXX-182DP
XX-XXXX-182DTL
XX-XXXX-182DHT
XX-XXXX-182DPTL
XX-XXXX-182DPHT
XX-XXXX-182DPTLHT
XX-XXXX-183A
XX-XXXX-183AP
XX-XXXX-183ATL
XX-XXXX-183AHT
XX-XXXX-183APTL
XX-XXXX-183APHT
XX-XXXX-186APTLHT
XX-XXXX-183C
XX-XXXX-183CP
XX-XXXX-183CTL
XX-XXXX-183CHT
XX-XXXX-183CPTL
XX-XXXX-183CPHT
XX-XXXX-183CPTLHT
XX-XXXX-183D
XX-XXXX-183DP
XX-XXXX-183DTL
XX-XXXX-183DHT
XX-XXXX-183DPTL
XX-XXXX-183DPHT
XX-XXXX-183DPTLHT
http://www.arieselec.com • info@arieselec.com
NORTH AMERICA
Frenchtown, NJ USA
TEL:(908) 996-6841
FAX:(908) 996-3891
abc
EUROPE
TEL: +44 870 240 0249
FAX: +44 871 919 6033
europe@arieselec.com
11019
REV.H
Page
1 of 3
PRINTOUTS OF THIS DOCUMENT MAY BE OUT OF DATE AND SHOULD BE CONSIDERED UNCONTROLLED
MOSFET turn-on and turn-off issues
Components used: P-channel MOSFET IRF9530, a diode 1N4001, a 5W20 ohm resistor, and a 220V to 15V transformer. Control signal: +12V, -12V for control. Now the connection is as follows: 220 passes thro...
kevin626 Analog electronics
The routines in the F5529 video training, can anyone give me some advice? !
I can't find it, I can't search it, and I can't find it on the official website! Where can I find the routines in the video training? Aunties and gods, please give me some! I always feel that I can on...
woaiweibo Microcontroller MCU
The domestic technical atmosphere is getting worse and worse
As the Internet develops, technical exchanges should become more and more active. Unfortunately, no matter in technical groups, WeChat groups, or BBS, we can find a problem, that is, fewer and fewer p...
wateras1 Talking
Regarding the 44b0-IIC problem, please help me if you have any questions.
I found the 44b0 iic program on the Internet, but when reading and writing E2PROM, I always read out ff. My development board uses st24c08 E2PROM. This problem has bothered me for a long time. I also ...
longbiao831 ARM Technology
Telephone Network Data Communication Using FSK Information Decoding
Caller Identification Delivery (CID) is a service provided by the telecommunications bureau to the called telephone user. It refers to the service that displays the caller's phone number, caller name,...
吸铁石上 RF/Wirelessly
Quad-axis, questions about I2C communication?
My understanding is this:But the result is this:I have learned I2C before, but I only learned about 1-to-1 communication. I don’t know much about 1-to-many communication. I hope you can give me some a...
╰◆◇敷衍╯ DIY/Open Source Hardware

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 343  2426  690  452  2563  7  49  14  10  52 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号