Rotary Switch, 5 Positions, DP5T, Latched, 0.25A, 28VDC, Solder Terminal, Standard Type Actuator, Through Hole-straight,
CategoryMechanical and electronic products    switch   
File Size603KB,6 Pages
ManufacturerGrayhill
Websitehttp://www.grayhill.com
Environmental Compliance
Download Datasheet Parametric View All

09A30-01-2-05N Online Shopping

Suppliers Part Number Price MOQ In stock  
09A30-01-2-05N - - View Buy Now

09A30-01-2-05N Overview

Rotary Switch, 5 Positions, DP5T, Latched, 0.25A, 28VDC, Solder Terminal, Standard Type Actuator, Through Hole-straight,

09A30-01-2-05N Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerGrayhill
Reach Compliance Codecompliant
ECCN codeEAR99
Factory Lead Time16 weeks
Is SamacsysN
Actuator typeSTANDARD TYPE
Contact (AC) maximum rated R load.25A@115VAC
Maximum contact current (AC)0.25 A
Maximum contact current (DC)0.25 A
Contact (DC) maximum rated R load.25A@28VDC
Maximum contact voltage (AC)115 V
Maximum contact voltage (DC)28 V
Graduation angle30 deg
JESD-609 codee4
Installation featuresTHROUGH HOLE-STRAIGHT
Number of positions5
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionDP5T
Switch typeROTARY SWITCH
Terminal surfaceGold (Au)
Termination typeSOLDER
Base Number Matches1
Multi-Deck Rotary Switches
SERIES 08
SERIES 09
0.5" Diameter, 1/4 Amp,
Standard, Military SR13
FEAtuRES
• Proven Quality in Thousands of
Applications
• Gold-plated Contact System
• 30°, 36°, 45°, 60° and 90° Angle
of Throw Options
• MIL Qualified Versions MIL-S-3786/13
DIMENSIONS
in inches (and millimeters)
Standard Style
Front view shows terminal location
of Series 8, 36° angle of throw.
Transpose rear view for terminal
location of other angles of throw.
.312 ± .020
(7,92 ± 0,51)
.375 ± .020
(9,53 ± 0,51)
.250 ± .020
(6,35 ± 0,51)
DIM. A + .046 – .020
(+ 0,05 – 0,51)
Rear Views
Series 09
30° Angle of throw
.562 ± .020
(14,27 ± 0,51)
DIA.
.750 ± .015
(19,05 ± 0,38)
OVER TERMINALS
0
9
.260 ± .015
(6,60 ± 0,38)
C
OF NON-TURN
L
TAB
.094 ± .010
(2,38 ± 0,25)
.135 ± .015 (3,43 ± 0,38)
DIM. B REF.
STUD
PROJECTION
#0 THREAD
15°
.562 (14,27) SER. 8
.625 (15,88) SER. 9
GRAyHILL
1
11
8
1
12
7
6
5
.387 (9,83) SER.8
.453 (11,51) SER. 9
± .015 (0,38)
SEE NOTE
.125 + .001 – .002
(3,18 + 0,03 – 0,05)
DIA.
COMMON LUG
.045 ± .003 (1,14 ± 0,08) DIA.
HOLE AFTER PLATING
INTEGRAL ASSEMBLy NUT,
DO NOT REMOVE
1/4-32 UNEF-2A THREAD
30°
COMMON LUG
NON-TURN TAB .062 ± .005
(1,58 ± 0,13) WIDE By
.020 ± .003 (0,51 ± 0,08) THICK
Series 08
36° Angle of throw
.687 ± .015
(17,45 ± 0,38)
OVER
TERMINALS
.500 ± .020
(12,7 ± 0,51)
DIA.
8
GRAyHILL
Note:
Common location for a single pole per
deck switch. For common location on
multi-pole switches, see circuit diagrams.
10
9
1
2
3
4
5
6
.960 (24,38)
1.228 (31,19)
1.496 (38,00)
1.764 (44,81)
2.032 (51,61)
2.550 (64,77)
.062 (1,57)
.062 (1,57)
.062 (1,57)
.062 (1,57)
.062 (1,57)
.312 (7,92)
12
14
16
18
20
22
16.0
18.5
21.0
23.5
26.0
28.5
7
8
9
10
11
12
2.818 (71,58)
3.086 (78,38)
3.354 (85,19)
3.622 (91,00)
3.890 (98,81)
4.158 (105,61)
.312 (7,92)
.312 (7,92)
.312 (7,92)
.312 (7,92)
.312 (7,92)
.312 (7,92)
24
26
28
30
32
34
31.0
33.5
36.0
38.5
41.0
43.5
COMMON
LUG
.033 ± .002
(0,84 ± 0,05) DIA.
HOLE AFTER
PLATING
Grayhill part number and date code marked on standard style detent cover label.
Customer part number marked on request. Grayhill part number and date code
printed on military style cover. Military number printed when required.
For rear view of 45°, 60° and 90°,
see circuit diagrams.
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
3
2
No.
of
Decks
Dimension
A
Dimension
B
Approx. Weight No.
Grams
of
Srs. 08 Srs. 09 Decks
Dimension
A
Dimension
B
Approx. Weight
Grams
Srs. 08 Srs. 09
36°
1
4
7
3
2
Rotary Switches
6
5
4
adc sampling problem
I want to use the ADC module to collect the battery voltage, and then use the SCI module to display it in software, but unfortunately I have not been successful. The sampling uses periodic interrupts,...
yuspace Microcontroller MCU
I also posted a question about the interrupt response time, SDLC communication
I want to use AM85C30 to implement synchronous communication (SDLC) in WinCE. The problem is that this chip has a 3-byte receive FIFO and no buffer for sending! For example, if I want to use 1Mbps com...
zhangssd Embedded System
Novel single-electrode touch switch circuit
[i=s]This post was last edited by jameswangsynnex on 2015-3-3 19:59[/i]...
lorant Mobile and portable
FPGA-Based Video Games
In order to balance work and life, someone suggested that I have a hobby. The hobby that piqued my interest was developing FPGA-based video games. Silicon devices, software and solutions are available...
lorant FPGA/CPLD
Share: Classic Code Vision AVR mistake! Be careful!!
Please see the following program: void Show_BMP(unsigned int Width,unsigned int Height) { unsigned long int position; position=0x4d200+0x3e+Width/7+Height*408; ... ... } There is absolutely no syntax ...
边城浪子 Microchip MCU
【CN0116】Using AD8210 and AD8274 to achieve high voltage, high precision current sensing and output level conversion
Circuit Function and BenefitsIntegrated devices such as the AD8210 simplify high-side current monitoring by providing a high voltage interface and enabling bidirectional current monitoring across a sh...
EEWORLD社区 ADI Reference Circuit

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2348  2143  1035  550  1804  48  44  21  12  37 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号