EEWORLDEEWORLDEEWORLD

Part Number

Search

54122-418-62-1600RLF

Description
Board Connector, 124 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Kinked Leads Terminal, Locking, Black Insulator, Receptacle
CategoryThe connector    The connector   
File Size107KB,1 Pages
ManufacturerAmphenol
Websitehttp://www.amphenol.com/
Environmental Compliance
Download Datasheet Parametric View All

54122-418-62-1600RLF Overview

Board Connector, 124 Contact(s), 2 Row(s), Male, Straight, 0.1 inch Pitch, Solder Kinked Leads Terminal, Locking, Black Insulator, Receptacle

54122-418-62-1600RLF Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
Reach Compliance Codecompliant
Is SamacsysN
body width0.19 inch
subject depth0.63 inch
body length6.2 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationSN ON NI
Contact completed and terminatedMatte Tin (Sn) - with Nickel (Ni) barrier
Contact point genderMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact styleSQ PIN-SKT
Insulation resistance5000000000 Ω
Insulator colorBLACK
insulator materialTHERMOPLASTIC
JESD-609 codee3
Manufacturer's serial number54122
Plug contact pitch0.1 inch
Match contact row spacing0.1 inch
Installation option 1LOCKING
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number2
Number of rows loaded2
Maximum operating temperature125 °C
Minimum operating temperature-65 °C
PCB contact patternRECTANGULAR
PCB contact row spacing2.54 mm
Plating thickness79u inch
Rated current (signal)3 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.12 inch
Terminal pitch2.54 mm
Termination typeSOLDER KINKED LEADS
Total number of contacts124
Base Number Matches1
PDM: Rev:K
STATUS:
Released
Printed: Mar 10, 2011
.
DALI bus power supply problem
[i=s]This post was last edited by zhaojun_xf on 2017-9-13 11:45[/i] I've been learning about the DALI bus recently, but I found that the power supply on the bus is a problem. I don't understand it. He...
zhaojun_xf Power technology
I used EVC4.0 to build a project, and this error occurred when I edited it directly. Please help me
LINK : fatal error LNK1123: failure during conversion to COFF: file invalid or corrupt Error executing link.exe. I used EVC4.0 to build a project, and this error occurred when I edited it directly. Pl...
mel1207 Embedded System
Several commonly used analog switches
Common analog switch information...
shangwen Analog electronics
CRC checksum generation algorithm
Some time ago, I wrote a post suggesting that beginners provide a program flow description instead of simply posting source code when asking for help. Below I give an example of a specific process des...
chunyang Embedded System
DIY Simple Solar Water Heater Model
Solar water heaters have become a widely used household item. By making a small solar water heater model, you can experience the benefits of solar water heaters collecting solar energy and making sola...
凯哥 Energy Infrastructure?
Can you do the design when you get a project?
The design I'm talking about is the process of breaking down requirements into software design. I've worked in some seemingly high-tech equipment companies, but they just started to argue, and there w...
freebsder Talking about work

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 937  2397  2768  336  1777  19  49  56  7  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号