• multiple speed options for different cooling needs
• tachometer signal and rotation detect options available
• auto restart protection standard on all models
MODEL
rated
(Vdc)
input
voltage
range
(Vdc)
input
current
1
max
(mA)
input
power
1
max
(W)
rated
speed
1
typ
(RPM±10%)
air
flow
2
(CFM)
static
pressure
3
(inch H
2
O)
noise
4
max
(dBA)
CFM-9225V-117-177
CFM-9225V-124-280
CFM-9225V-127-320
CFM-9225V-130-340
CFM-9225V-139-416
CFM-9225V-142-437
CFM-9225V-145-455
CFM-9225V-224-280
CFM-9225V-227-320
CFM-9225V-230-340
CFM-9225V-239-420*
CFM-9225V-242-440*
CFM-9225V-245-460*
CFM-9225V-339-420*
CFM-9225V-342-440*
CFM-9225V-345-460*
Notes:
1.
2.
3.
4.
5.
6.
*.
12
12
12
12
12
12
12
24
24
24
24
24
24
48
48
48
4.5~13.8
4.5~13.8
4.5~13.8
4.5~13.8
6.0~13.8
6.0~13.8
6.0~13.8
8.0~27.6
8.0~27.6
8.0~27.6
10.0~27.6
10.0~27.6
10.0~27.6
24.0~56.0
24.0~56.0
24.0~56.0
54
87
121
161
265
322
426
51
64
87
178
207
253
119
125
144
0.65
1.05
1.46
1.94
3.18
3.87
5.12
1.23
1.54
2.09
4.28
4.97
6.08
5.72
6.00
6.92
1700
5
2400
2700
3000
3900
4200
4500
2400
2700
3000
3900
4200
4500
3900
4200
4500
28.4
39.5
45.0
51.5
65.0
70.0
75.0
39.5
45.0
51.5
65.0
70.0
75.0
65.0
70.0
75.0
0.05
0.10
0.13
0.15
0.25
0.30
0.35
0.10
0.13
0.15
0.25
0.30
0.35
0.25
0.30
0.35
17.7
28.0
32.0
34.0
41.6
43.7
45.5
28.0
32.0
34.0
42.0
44.0
46.0
42.0
44.0
46.0
At rated voltage, 25°C, 0 inch H
2
0 static pressure, after 10 minutes
As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 inch H
2
0 static pressure
As per AMCA 210 or DIN 24163, at rated voltage, stabilized RPM, 0 CFM airflow.
Measured in a semi-anechoic chamber with background noise < 15 dBA at 1 m from the fan intake.
Typical rated speed is measured as RPM±15% at rated voltage.
All specifications are measured at 25°C, 65% relative humidity unless otherwise specified.
Discontinued models.
PART NUMBER KEY
CFM-9225V-117-177 -
XX
-
CXX
Base Number
Fan Signals
“blank” = no signals
11 = rotation detector signal
20 = tachometer signal
cuidevices.com
Reserved for Custom
Configurations
Additional Resources:
Product Page
|
3D Model
CUI Devices
│
SERIES:
CFM-92V
│
DESCRIPTION:
DC AXIAL FAN
date
02/10/2020
│
page
2 of 10
INPUT
parameter
operating input voltage
1
conditions/description
12 Vdc input models
24 Vdc input models
48 Vdc input models
12 Vdc input models
24 Vdc input models
48 Vdc input models
min
4.5
10.0
24.0
typ
12
24
48
4.5
8
24
max
13.8
27.6
56.0
units
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
starting voltage
Note:
2
1. See Model section on page 1 for specific input voltage ranges.
2. The starting voltage for models CFM-9225V-139-416, CFM-9225V-142-437, and CFM-9225V-145-455 is 6 Vdc. TThe starting voltage for models CFM-9225V-239-420,
CFM-9225V-242-440, and CFM-9225V-245-460 is 10 Vdc.
PERFORMANCE
3
parameter
rated speed
air flow
static pressure
noise
Note:
conditions/description
at rated voltage, 25°C, after 10 minutes
at 0 inch H
2
O, see performance curves
at 0 CFM, see performance curves
at 1 m
min
1700
28.4
0.05
17.7
typ
max
4500
75.0
0.35
46.0
units
RPM
CFM
inch H
2
O
dBA
3. See Model section on page 1 for specific values.