Tantalum Surface Mount Capacitors – MIL–PRF (CWR Style)
T492 Series MIL–PRF–55365/8 (CWR11 Style)
Electrical Characteristics
1000
ESR vs. Frequency
100
T492B225/020_IMP
T492C685/020_IMP
Capacitance vs. Frequency
T492B225/020
T492C685/020
T492D156/020
100
T492D156/020_IMP
T492B225/020_ESR
T492C685/020_ESR
T492D156/020_ESR
Impedance, ESR (Ohms)
10
10
Capacitance (µF)
1,000,000
10,000,000
1
1
0.1
0.1
100
1,000
10,000
Frequency (Hz)
100,000
0.01
100
1,000
10,000
Frequency (Hz)
100,000
1,000,000
10,000,000
Dimensions – Millimeters (Inches)
Metric will govern
SIDE VIEW
L
H
P
P
Termination cutout
at KEMET's option,
either end
END VIEW
W
Solderable
Surfaces
BOTTOM VIEW
H
2
W
2
½ H
2
Min.
Case Size
KEMET
A
B
C
D
H
1.6 ±0.2
(0.063 ±0.008)
1.9 ±0.2
(0.075 ±0.008)
2.5 ±0.3
(0.098 ±0.012)
2.8 ±0.3
(0.110 ±0.012)
H
2
Minimum
0.7 (0.028)
0.7 (0.028)
1.0 (0.039)
1.0 (0.039)
L
Component
P ±0.3 (0.012)
0.8 (0.031)
0.8 (0.031)
1.3 (0.051)
1.3 (0.051)
W
1.6 ±0.2
(0.063 ±0.008)
2.8 ±0.2
(0.110 ±0.008)
3.2 ±0.3
(0.126 ±0.012)
4.3 ±0.3
(0.169 ±0.012)
W
2
±0.1 (0.004)
1.2 (0.047)
2.2 (0.087)
2.2 (0.087)
2.4 (0.094)
3.2 ±0.2
(0.126 ±0.008)
3.5 ±0.2
(0.138 ±0.008)
6.0 ±0.3
(0.236 ±0.012)
7.3 ±0.3
(0.287 ±0.012)
Total Weight
(mg)
58.97
102.3
224.2
412.33
Note: When option C is selected for lead material, add an additional 0.38 mm (0.015 inch) to the above tolerances for "L", "W", "H", "P", "W2" and "H2"
These weights are provided as reference. If exact weights are needed, please contact your KEMET Sales Representative
Tantalum Surface Mount Capacitors – MIL–PRF (CWR Style)
T492 Series MIL–PRF–55365/8 (CWR11 Style)
Table 1 – Ratings & Part Number Reference
Rated
Voltage
VDC @ 85ºC
4
4
4
4
4
4
4
4
6
6
6
6
6
6
6
6
6
6
10
10
10
10
10
10
10
10
10
15
15
15
15
15
15
15
15
15
20
20
20
20
20
20
20
20
VDC @ 85ºC
Rated Case Code/
Case Size
Cap
µF
2.2
4.7
6.8
10
15
33
68
100
1.5
2.2
3.3
4.7
6.8
10
15
22
47
68
1
1.5
2.2
3.3
4.7
6.8
15
33
47
0.68
1
1.5
2.2
3.3
4.7
10
22
33
0.47
0.68
1
1.5
2.2
3.3
4.7
6.8
µF
KEMET/EIA
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
D/7343-31
D/7343-31
A/3216-18
A/3216-18
A/3216-18
B/3528-21
B/3528-21
B/3528-21
C/6032-28
C/6032-28
KEMET/EIA
KEMET Part
Number
(See below for
part options)
T492A225(1)004(2)(3)(4)
T492A475(1)004(2)(3)(4)
T492B685(1)004(2)(3)(4)
T492B106(1)004(2)(3)(4)
T492B156(1)004(2)(3)(4)
T492C336(1)004(2)(3)(4)
T492D686(1)004(2)(3)(4)
T492D107(1)004(2)(3)(4)
T492A155(1)006(2)(3)(4)
T492A225(1)006(2)(3)(4)
T492A335(1)006(2)(3)(4)
T492B475(1)006(2)(3)(4)
T492B685(1)006(2)(3)(4)
T492B106(1)006(2)(3)(4)
T492C156(1)006(2)(3)(4)
T492C226(1)006(2)(3)(4)
T492D476(1)006(2)(3)(4)
T492D686(1)006(2)(3)(4)
T492A105(1)010(2)(3)(4)
T492A155(1)010(2)(3)(4)
T492A225(1)010(2)(3)(4)
T492B335(1)010(2)(3)(4)
T492B475(1)010(2)(3)(4)
T492B685(1)010(2)(3)(4)
T492C156(1)010(2)(3)(4)
T492D336(1)010(2)(3)(4)
T492D476(1)010(2)(3)(4)
T492A684(1)015(2)(3)(4)
T492A105(1)015(2)(3)(4)
T492A155(1)015(2)(3)(4)
T492B225(1)015(2)(3)(4)
T492B335(1)015(2)(3)(4)
T492B475(1)015(2)(3)(4)
T492C106(1)015(2)(3)(4)
T492D226(1)015(2)(3)(4)
T492D336(1)015(2)(3)(4)
T492A474(1)020(2)(3)(4)
T492A684(1)020(2)(3)(4)
T492A105(1)020(2)(3)(4)
T492B155(1)020(2)(3)(4)
T492B225(1)020(2)(3)(4)
T492B335(1)020(2)(3)(4)
T492C475(1)020(2)(3)(4)
T492C685(1)020(2)(3)(4)
(See below for
part options)
MIL–PRF–55365/8
DC
Part Number
Leakage
(See below for
part options)
CWR11C(6)225(1)(2)(5)
CWR11C(6)475(1)(2)(5)
CWR11C(6)685(1)(2)(5)
CWR11C(6)106(1)(2)(5)
CWR11C(6)156(1)(2)(5)
CWR11C(6)336(1)(2)(5)
CWR11C(6)686(1)(2)(5)
CWR11C(6)107(1)(2)(5)
CWR11D(6)155(1)(2)(5)
CWR11D(6)225(1)(2)(5)
CWR11D(6)335(1)(2)(5)
CWR11D(6)475(1)(2)(5)
CWR11D(6)685(1)(2)(5)
CWR11D(6)106(1)(2)(5)
CWR11D(6)156(1)(2)(5)
CWR11D(6)226(1)(2)(5)
CWR11D(6)476(1)(2)(5)
CWR11D(6)686(1)(2)(5)
CWR11F(6)105(1)(2)(5)
CWR11F(6)155(1)(2)(5)
CWR11F(6)225(1)(2)(5)
CWR11F(6)335(1)(2)(5)
CWR11F(6)475(1)(2)(5)
CWR11F(6)685(1)(2)(5)
CWR11F(6)156(1)(2)(5)
CWR11F(6)336(1)(2)(5)
CWR11F(6)476(1)(2)(5)
CWR11H(6)684(1)(2)(5)
CWR11H(6)105(1)(2)(5)
CWR11H(6)155(1)(2)(5)
CWR11H(6)225(1)(2)(5)
CWR11H(6)335(1)(2)(5)
CWR11H(6)475(1)(2)(5)
CWR11H(6)106(1)(2)(5)
CWR11H(6)226(1)(2)(5)
CWR11H(6)336(1)(2)(5)
CWR11J(6)474(1)(2)(5)
CWR11J(6)684(1)(2)(5)
CWR11J(6)105(1)(2)(5)
CWR11J(6)155(1)(2)(5)
CWR11J(6)225(1)(2)(5)
CWR11J(6)335(1)(2)(5)
CWR11J(6)475(1)(2)(5)
CWR11J(6)685(1)(2)(5)
(See below for
part options)
µA @ +20ºC
Max/5 Min
0.5
0.5
0.5
0.5
0.6
1.3
2.7
4.0
0.5
0.5
0.5
0.5
0.5
0.6
0.9
1.3
2.8
4.1
0.5
0.5
0.5
0.5
0.5
0.7
1.5
3.3
4.7
0.5
0.5
0.5
0.5
0.5
0.7
1.5
3.3
5.0
0.5
0.5
0.5
0.5
0.5
0.7
0.9
1.4
µA @ +20ºC
Max/5 Min
DF
% @ +20ºC
120 Hz Max
6.0
6.0
6.0
6.0
6.0
6.0
6.0
8.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
4.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
6.0
6.0
4.0
4.0
4.0
6.0
6.0
6.0
6.0
6.0
% @ +20ºC
120 Hz Max
ESR
Ω @ +20ºC
100 kHz Max
8.0
8.0
5.5
4.0
3.5
2.2
1.1
0.9
8.0
8.0
8.0
5.5
4.5
3.5
3.0
2.2
1.1
0.9
10.0
8.0
8.0
5.5
4.5
3.5
2.5
1.1
0.9
12.0
10.0
8.0
5.5
5.0
4.0
2.5
1.1
0.9
14.0
12.0
10.0
6.0
5.0
4.0
3.0
2.4
Ω @ +20ºC
100 kHz Max
Maximum
Operating
Temp
ºC
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
125
ºC
MSL
Reflow Temp
≤ 260ºC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Reflow Temp
≤ 260ºC
Rated
Voltage
Rated
Cap
Case Code/
Case Size
KEMET Part Number
MIL–PRF–55365/8
Part Number
DC
Leakage
DF
ESR
Maximum
Operating
Temp
MSL
(1) To complete KEMET/CWR part number, insert M for ±20%, K for ±10%, or J for ±5%. Designates Capacitance tolerance.
(2) To complete KEMET/CWR part number, insert failure rate letter per the Ordering Information found on page 2. Designates Reliability Level.
(3) To complete KEMET part number, insert B = Gold Plated, C = Hot solder dipped, H or S = Solder Plated or K = Solder Fused. Designates Termination Finish.
(4) To complete KEMET part number, insert 4250 = +25°C after Weibull, 4251 = −55°C +85°C after Weibull, or 4252 = −55°C +85°C before Weibull. Designates
Surge current option.
(5) To complete CWR part number, insert A = +25°C after Weibull, B = −55°C +85°C after Weibull, C = −55°C +85°C before Weibull or Z = None. Designates
Surge current option.
(6) To complete CWR part number, insert B = Gold Plated, C = Hot Solder Dipped, H = Solder Plated or K = Solder Fused. Designates Termination Finish.
Refer to Ordering Information for additional detail.
MOS model recommendationI need PMOS and NMOS, with SC-70-3 or SOT23 package. I pay special attention to the Vth turn-on voltage, Idss leakage current, and on-resistance Ron. The smaller the better. Th...
Dear experts, when designing some fixture PCB boards with relatively large network relationships in PCB (directly drawing the PCB without a schematic diagram), if you follow the general practice to bu...
Have you ever eaten something that looks disgusting but tastes delicious, such as stinky tofu? What else can compare to something that looks disgusting but tastes really good?...
Reprinted from http://blog.chinaunix.net/uid-12617001-id-3766199.html. Original work, reprinting is allowed. Please be sure to indicate the original source, author information and this statement in th...
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
introduction
For the voltage regulator modules (VRMs) that power the latest computer central processing units (CPUs), power supply designers have historically used multiphase interleaved b...[Details]
1. Introduction
With the gradual automation and modernization of industrial control systems, fieldbus control systems have received more and more attention and application. CAN bus is currentl...[Details]
1. Introduction
At present, most lighting equipment still uses traditional energy for lighting. Making full use of solar energy as the energy supply for lighting equipment is of great si...[Details]
Overview:
This paper introduces a method of connecting a CAN-bus network with Ethernet to form a medium-sized remote monitoring/data transmission network.
CAN (Controller Area Network) is ...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
1 Introduction
The Third Steel Plant of Jigang Group is a key investment project of Jigang Group during the "15th Five-Year Plan". It has introduced first-class domestic and foreign advanced eq...[Details]
Many battery-powered systems require a visual indicator to show when the battery needs to be replaced. LEDs are commonly used for this purpose, but they consume at least 10mA of current. This con...[Details]
Experimental tasks
A DS18B20 is used to form a temperature measurement system. The temperature measurement accuracy reaches 0.1 degrees. The temperature range is between -20 degrees and +50 de...[Details]
Capacitors
are basic components in various electronic devices and are widely used for bypassing, coupling,
filtering
, tuning, etc. in electronic circuits. However, to use capacitors,...[Details]
In 2012, more than half of the cars in the European, Japanese and American car markets will be equipped with color displays, navigation systems, satellite communications and other in-vehicle infota...[Details]
At present, the traffic congestion in cities is quite serious. According to relevant news reports: In China, the traffic congestion has expanded from megacities such as Beijing, Shanghai, and Guangzho...[Details]
Only a small number of LED manufacturers can produce high-quality LEDs. For applications that are only used for simple indication, low-quality LEDs are sufficient. However, high-quality LEDs must...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]