EEWORLDEEWORLDEEWORLD

Part Number

Search

BK/ABC-3B

Description
Electric Fuse, Fast Blow, 3A, 250VAC, 125VDC, 100A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size114KB,2 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

BK/ABC-3B Overview

Electric Fuse, Fast Blow, 3A, 250VAC, 125VDC, 100A (IR), Inline/holder

BK/ABC-3B Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
Reach Compliance Codeunknow
Other featuresRATED BREAKING CAPACITY AT 125 VDC: 10000 A
Fusing characteristicsFAST
body height31.75 mm
Body length or diameter6.35 mm
Circuit protection typeELECTRIC FUSE
Joule integral nominal19 J
Manufacturer's serial numberABC
Installation featuresINLINE/HOLDER
method of packingBOX
physical size6.35mm x 31.75mm
Rated breaking capacity100 A
Rated current3 A
Rated voltage (AC)250 V
Rated voltage (DC)125 V
GuidelineCSA; UL
surface mountNO
Terminal surfaceNickel (Ni)
Terminal shapeEND CAP
Base Number Matches1
1/4" x 1-1/4" Fuses
ABC Series, Fast Acting, Ceramic Tube
Description
• Fast-acting, ceramic tube
• Optional axial leads available
• 1/4 x 1-1/4 (6.3mm x 32mm) physical size
• Ceramic tube, nickel-plated brass endcap construction
• UL Listed product meets standard 248-14
ELECTRICAL CHARACTERISTICS
% of Amp Rating
Opening Time
100%
4 Hours Minimum
135%
60 Minutes maximum
200%
120 Seconds Maximum
RoHS
2002/95/EC
Agency Information
• UL Listed Guide & File numbers (ABC 1/4 - 15A):
JDYX & E19180.
• UL Recognition Guide & File numbers (ABC 18 - 30A):
JDYX2 & E19180.
• CSA Certification Record No: 053787 C 000 &
Class No: 1422 01 & 1422 30.
Environmental Data
• Shock: 1/4A and 1/2A – MIL-STD-202,
Method 213, Test Condition I;
1A thru 30A – MIL-STD-202, Method 207,
(HI Shock)
• Vibration: 1/4A thru 30A – MIL-STD-202,
Method 204, Test Condition C (Except 5g, 500HZ)
Ordering
• Specify packaging, product, and option code
Dimensions
(
mm
in
)
Drawing Not to Scale
SPECIFICATIONS
Product
Code
ABC-1/4
ABC-1/2
ABC-3/4
ABC-1
ABC-1-1/2
ABC-2
ABC-2-1/2
ABC-3
ABC-4
ABC-5
ABC-6
ABC-7
ABC-8
ABC-10
ABC-12
ABC-15
ABC-20
ABC-25
ABC-30
Voltage
Rating
AC
DC
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
250V
125V
125V
125V
125V
125V
AC Interrupting
Rating
250V
125V
35A
10000A
35A
10000A
35A
10000A
35A
10000A
100A
10000A
100A
10000A
100A
10000A
100A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
200A
10000A
750A
10000A
750A
10000A
400A
1000A
-
1000A
-
1000A
DC Interrupting
Rating
125V
75V
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
10000A
-
400A
1000A
400A
1000A
Typical DC Cold
Resistance**
(ohms)
3.000
0.788
0.303
0.197
0.1175
0.0755
0.05875
0.0435
0.02975
0.0286
0.02315
0.0183
0.0146
0.01205
0.0068
0.005425
0.00366
0.00263
0.002225
Typical
Melting I
2
t†
AC
0.02
0.19
0.8
1.4
2.9
4.2
8.53
19.5
29.1
16.4
31.6
73.2
111.9
215.6
129.6
200.2
550.8
839.3
1,429
Typical
Voltage
Drop‡
3.25
0.51
0.42
0.35
0.35
0.25
0.26
0.25
0.25
0.23
0.24
0.20
0.17
0.15
0.11
0.12
0.13
0.12
0.14
Traditional Ferrule Fuses - Ferrule Type
** DC Cold Resistance (Measured at
≤10%
of rated current)
† Typical Melting I
2
t (A
2
Sec) (I
2
t was measured at listed interrupting rating and rated voltage. Measured at 70% to 80% power factor on AC)
‡ Typical Voltage Drop (Voltage drop was measured at 25°C±3°C ambient temperature at rated current)
OC-80
Please recommend some ARM introductory tutorials!!
I want to learn ARM. Can anyone recommend me some ARM tutorials? Thanks!...
businiao0002007 ARM Technology
wince platform audio sampling rate? ?
I designed a sound acquisition program for WinCE platform, but I found that I can't set the sampling rate to 44.1K? ! The highest can only be 22.05K? ! At this sampling rate, a sine wave with a higher...
axlylee Embedded System
Who has used VS2005 to code ARM assembly code?
Compiling assembly using SIMD under WM?...
oldhouse05 ARM Technology
Embedded Linux Learning Route Planning
ARM+LINUX route, focusing on embedded Linux operating system and its application software development goals: (1) Master the structure and principle of mainstream embedded microprocessors (preliminaril...
Nuli-IT Linux and Android
Today is the summer solstice. I heard that those who went out at noon had no shadow.
My current situation should be: "Sunrise in the east, rain in the west" White clouds, clear sky, but it is raining, sunny and rainy " The Chinese Astronomical Calendar shows that the Summer Solstice, ...
nmg Talking
Panta STM32H750 Part 6 (Using timer synchronization to generate a specified number of PWM pulses)
In the previous post, the two output-specified PWM pulse number schemes proposed by the original poster have two disadvantages. The first is that either the output pulse number is limited, with a maxi...
RCSN stm32/stm8

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2396  1616  201  1222  818  49  33  5  25  17 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号