Description
Ceramic Capacitor, Ceramic, 3600V, 3.03% +Tol, 3.03% -Tol, C0G, 30ppm/Cel TC, 0.0000033uF, Surface Mount, 2425, RADIAL LEADED
CategoryPassive components    capacitor   
File Size686KB,5 Pages
ManufacturerPassive Plus Inc
Download Datasheet Parametric View All

2225C3R3BFN362XC Overview

Ceramic Capacitor, Ceramic, 3600V, 3.03% +Tol, 3.03% -Tol, C0G, 30ppm/Cel TC, 0.0000033uF, Surface Mount, 2425, RADIAL LEADED

2225C3R3BFN362XC Parametric

Parameter NameAttribute value
Objectid7018206943
package instruction, 2425
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSTANDARD: MIL-PRF-55681, MIL-PRF-123
capacitance0.0000033 µF
Capacitor typeCERAMIC CAPACITOR
dielectric materialsCERAMIC
JESD-609 codee4
Installation featuresSURFACE MOUNT
multi-layerNo
negative tolerance3.03%
Number of terminals2
Maximum operating temperature125 °C
Minimum operating temperature-55 °C
Package shapeRECTANGULAR PACKAGE
method of packingWAFFLE PACK
positive tolerance3.03%
Rated (DC) voltage (URdc)3600 V
size code2425
surface mountYES
Temperature characteristic codeC0G
Temperature Coefficient30ppm/Cel ppm/°C
Terminal surfaceSilver (Ag)
Terminal shapeFLAT
Traditional High Q (>10,000) Low ESR Capacitors
2225C/P (.220” x .250”)
2225C/P (.220” x .250”)
2225C/P ( .220
x .250)
Product Features
High Q, High RF Current/Voltage, High RF Power, Low ESR/ESL, Ultra- Stable
Performance.
Product Application
Typical Functional Applications: Bypass, Coupling, Tuning, Impedance Matching and D.C. Blocking.
Typical Circuit Applications: UHF/VHF RF Power Amplifiers, Antenna Tuning, Plasma Chambers
and Medical.
2225C/P Capacitance Table
Cap.
Code
pF
Tol.
Rated Cap.
Code
WVDC pF
NPO=C; P90=P
Tol.
Rated Cap.
Code
WVDC pF
Tol.
Rated Cap.
Code
WVDC pF
Tol.
Rated
WVDC
1500V
Code
152
or
2000V
Code
202
0.5
0.6
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
0R5
0R6
0R7
0R8
0R9
1R0
1R1
1R2
1R3
1R4
1R5
2500V
Code
252
or
3600V
Code
362
3.9
4.3
4.7
5.1
5.6
6.2
6.8
7.5
8.2
9.1
10
3R9
4R3
4R7
5R1
5R6
6R2
6R8
7R5
8R2
9R1
100
2500V
Code
252
or
3600V
Code
362
F,G,
J,K
B,
C,D
36
39
43
47
51
56
62
68
75
82
91
360
390
430
470
510
560
620
680
750
820
910
2500V
Code
252
or
3600V
Code
362
330
360
390
430
470
510
560
620
680
750
F,G,
J,K
820
331
361
391
431
471
511
561
621
681
751
821
1.6
1.7
1.8
1.9
2.0
2.1
2.2
2.4
2.7
3.0
3.3
3.6
1R6
1R7
1R8
1R9
2R0
2R1
2R2
2R4
2R7
3R0
3R3
3R6
B,
C,D
11
12
13
15
16
18
20
22
24
27
30
33
110
120
130
150
160
180
200
220
240
270
300
330
100
110
120
130
150
160
180
200
220
240
270
300
101
111
121
131
151
161
181
201
221
241
271
301
910
1000
1100
2500V
Code
252
or
3000V
Code
302
1200
1500
1800
2200
2700
911
102
112
122
152
182
222
272
F,G,
J,K
1000V
Code
102
or
1500V
Code
152
500V
Code
501
Remark: special capacitance, tolerance and WVDC are available, consult with PASSIVE PLUS.
Is it feasible to use the LIS2MDL array to achieve magnetic positioning of an inertial guided AGV?
[i=s]This post was last edited by littleshrimp on 2020-9-12 22:22[/i]I want to make an AGV recently . I have heard of it before but never touched it. I checked some information and it seems that the m...
littleshrimp MEMS sensors
Comparison of digital and analog signals
Which is better, digital signal or analog signal, in terms of efficiency, mainly speed. I want to ask, is there no comparison? Can you explain it? Please give me some advice. >>>...
daochang Embedded System
What to do if stm8 I/O is not used
If the i/o is not used, I see from the datasheet that it must be pulled up or down.What will happen if it is left floating?What unexpected situations will occur?...
riscbbs stm32/stm8
My experience in getting started with UCOS
When I first started learning UCOS, I was always anxious to learn it all at once. In fact, the more anxious I was, the harder it was to get started. At the beginning, I always wanted to find ready-mad...
chenbangxuboy Real-time operating system RTOS
Surely the length of an instruction cannot exceed the width of the instruction register?
Surely the length of an instruction cannot exceed the width of the instruction register?...
snailsnail Embedded System
How to read circuit diagrams. Recommended resources: 12. How to read electrical control circuit diagrams
[align=center][size=5]How to read circuit diagrams Recommended resources 12. [color=rgb(0, 0, 0)][backcolor=rgb(237, 235, 235)][font=微软雅黑]How to read electrical control circuit diagrams [/font][/backc...
tiankai001 Download Centre

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2037  1457  2329  2513  2019  42  30  47  51  41 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号